datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

DatasheetsChassis2modelRepair tipsFulltext searchCables & Connectors
Repair tips

Electronic appliance repair tips database - TV (LCD,TFT,Plasma,Digital), Monitor, VCR, DVD recorder and player, Digital camera, Audio equipment, Microwave ovens, Phone systems, Computer repair

MakeModelProblemSolutionDate
Found: 285
AkuraCX24Dead - hesitant to come on originallyR811 560k in psu pri hi res14-09-04
AkuraCX24No sigstuning volts fixed at 31v - R023 47k o/c14-09-04
AkuraCX24Sound lowCheck for dry joints C622 1mfd bi-polar cap behind audio IC14-09-04
AkuraCX24Txt lines across screenC310 4µ7 250v in fop stage14-09-04
AkuraCX240Snowy pic with 2" of field scanR842 39k 1w in LOP stage14-09-04
Bush2420sound muting on some chans & no search locksync pulses at Q403 varying - base bias res R424 750k o/c14-09-04
BushT24Contrast - dark picture.TR203 ( BC557 ) may check ok.14-09-04
BushT24No colourR229 ( 3k6 ) go's high.14-09-04
BushT24Shutdown - int.R476 ( 1M ) o/c.14-09-04
BushT24Shutdown - standby.Zener D472 ( BZX79B6V2 ) leaky.14-09-04

BushT24Teletext - interference.C313 ( 4.7uf ) o/c.14-09-04
BushT24EDead.FS803 ( 3 15 ) , TR801 , D801-4 T801.14-09-04
DaewooCP240 GB20F8T2Dead or relay clicking onlyC840 47µ 25v in psu pri14-09-04
DaewooCP240 GB20F8T2No control of vol or chan change - neg pic with fb lines1703 eprom available from seme part number CAT24C08p at ?814-09-04
DaewooCP240 GB20F8T2To set up & service mode…Put set in standby then press blue yellow green red & standby to get into svc, to adjust use 4 & 7, vert centre 5 & 8 size 6 & 9 slope yellow, blue horiz centre 123 & above to ajust RGB14-09-04
DiamondDM002 Daewoo 24PFDeadTOP214, D12 1N4148, D819 18v zener on main board & fuse14-09-04
Finlux3024BLACK BANDS ON SCREEN WORSE AT TOPCK8 0.1uF ( UNDER FIELD HEATSINK )14-09-04
Finlux3024Int syncRa13 & Ra17 on sigs/IF panel never been soldered14-09-04
Finlux3024There was intermittent loss of line and field syncOne end of both Ra13 and Ra17 had never been soldered.14-09-04
Finlux3024FLINE TRANSISTOR SC REPLACEMENT BLOWS AFTER 2-3hrsTz3 LINE DRIVER US + DRY JOINTS14-09-04
Finlux3024FNo pic - faint vert line down centre at sw offC219 scan coupling cap 470nf 250v split14-09-04
Finlux3024FNo signals received - ok on scartICi1 SDA3203-314-09-04
GECTVC2437BInt off - no power LEDDry joints PSU R183 22k & tfmr14-09-04
GECTVC2460No pic at sw on aft LOPTx replacementJudicious adj of A1's14-09-04
Grundig2401TrippingCHECK L-O-TRANS & L51914-09-04
Grundig2401TRIPSL519 SHORTED TURNS14-09-04
Grundig55 245BLOWS LOP. TRANSISTOR ( MAY RUN FOR SHORT TIME. )CHECK 220mfd BASE DRIVE14-09-04
Grundig8240Lack of blue.R1958 o/c.14-09-04
GrundigCUC2400Dead.BU508D.14-09-04
GrundigCUC2400Flashing & intermittent picture.Poor contact on CRT base board , & cap shorting.14-09-04