Make | Model | Problem | Solution | Date |
| | | |
Found: 76
|
Philips | 29GX1995 AnubisS/BB | Dead | Replaced - Diode 6528 (BZX55) and 6519 (BZX55), Resistor 3503 (1.5R 7W), IC 7510 (UC3842BN) and FET 7513 (H12N60F1). | 14-09-04 |
Philips | ANUBIS-S | "Curtain" effect at left side of the screen at dark pictures | It is recommended to adapt in the line drive part of the 25"
Anubis S BB set:
Replace R3453 and R3454 by a 4k7 5% resistor fuse 4822 052 10472
REMARKS :
Introduced in production week 9417
(the seriousness of the effect differs from set to set) | 14-09-04 |
Philips | ANUBIS-S | After warmup pix shrinks, stamp raster then blackout. | +8V supply to IC 7225 increases.
+8V regulator IC 7218(78M08) no heat sink.
Change the IC 7218 and use a heat sink.
| 14-09-04 |
Philips | ANUBIS-S | At NTSC the green colour is a bit yellow / red / orange | An new version of IC7225 will be introduced with a new
NTSC matrix.
This IC7225 is fully backwards compatible with the TDA8362C/N3.
New IC7225 TDA8362E/N2 4822 209 33398
Available from week 9412 onwards
REMARKS :
Introduced in production wee | 14-09-04 |
Philips | ANUBIS-S | AV input mode | AV input mode
-------------
If it is required that a set stays in AV input mode after switching
on, R3627 (1 K ohm) near microprocessor IC7600 has to be removed.
| 14-09-04 |
Philips | ANUBIS-S | Bad catching of colour carrier | Replace:
C2275 by 220p (5322 122 32334)
C2277 by 220p (5322 122 32334)
C2278 by 220p (5322 122 32334)
C2279 by 220p (5322 122 32334)
REMARKS :
Introduced in production week 9328
| 14-09-04 |
Philips | ANUBIS-S | Bad colour switching performance | Replace:
- TS7278 by BF494B (4822 130 41376)
- R3278 by 8k2 (4822 116 52303)
REMARKS :
Introduced in production week 9315
| 14-09-04 |
Philips | ANUBIS-S | Bad picture geometry | Replace 2447 by 680 pF 2 kV 4822 126 12269
REMARKS :
Introduced in production week 9319
| 14-09-04 |
Philips | ANUBIS-S | Bad picture sharpness of the 25" Anubis S BB | It is recommended to replace on the CRT panel (diagram EE)
C2304, C2317 and C2330 by 470p 10% 50V 5322 122 32311
R3338, R3339 and R3340 by 22k 5% 0.16W 4822 116 52257
L5306, L5319 and L5328 by 820uH 10% 4822 157 71153
REMARKS :
Intr | 14-09-04 |
Philips | ANUBIS-S | C2505 discharge to prevent damage of TS7513 | C2505 discharge to prevent damage of TS7513
-------------------------------------------
For all ANUBIS-S sets:
Always switch off the set under repair and discharge the big
rectifier capacitor C2505 (diagram A) with a 1k/5W resistor
(e.g 4822 053 32122) b | 14-09-04 |
|
Philips | ANUBIS-S | Codenumber information | Codenumber information
----------------------
LOT for TXT and non TXT sets Anubis S AA & BB & CC
--------------------------------------------------
LOT for Anubis S AA & CC sets:
14-20-21" non TXT sets: 4822 140 10465
14-20-21" TXT sets: 48 | 14-09-04 |
Philips | ANUBIS-S | Combination of Picture tube - Yoke - Multipole | Combination of Picture tube - Yoke - Multipole
----------------------------------------------
Only for 14" Anubis S AA and CC sets
For the 14" Anubis S AA and CC sets, depending on the production
date and the typenumber, 3 different tubes are used.
Every | 14-09-04 |
Philips | ANUBIS-S | Correction | Correction
----------
Only for /77 (TRINORMA)
Tuner for /77 Anubis S sets is not published in spanish AA service
manual Anubis S 4822 727 19719.
Tuner UV936E/IEC 4822 210 10582
Please add to your service manuals
| 14-09-04 |
Philips | ANUBIS-S | Correction on Service Information Anubis-S BB 94.0 | Correction on Service Information Anubis-S BB 94.03
---------------------------------------------------
For BB sets 25" and 29"
Diode 6521 is indicated in power supply diagram as BZX79-C4V7.
This should be:
- For 25" BZX79-B18 Service code 4822 130 31024 | 14-09-04 |
Philips | ANUBIS-S | Correction Service Manual | Correction Service Manual
-------------------------
In Anubis S AA service manual in the spare parts list the
next parts are wrong:
- D6445 must be BYD34M (4822 130 83457)
- D6447 must be BYD34M (4822 130 83457)
Missing in the spare parts list is micropr | 14-09-04 |
Philips | ANUBIS-S | Correction Service Manual | Correction Service Manual
-------------------------
For all versions:
In the service manual AA page 7 and in product survey 1993-2 all
sets with /58/62/75/79 are indicated to be "140 V only" mains
voltage sets. This is wrong as "140 V only" sets do not e | 14-09-04 |
Philips | ANUBIS-S | Defocus of the teletext characters | It is recommended on the teletext panel (diagram N) to:
replace D6813 by a LLZ-C3V0 4822 130 80879
REMARKS :
Introduced in production week 9407
| 14-09-04 |
Philips | ANUBIS-S | Distortion in BTSC sound | Replace R3824 by 18k (4822 051 20183)
Replace R3825 by 18k (4822 051 20183)
REMARKS :
Introduced in production week 9336
| 14-09-04 |
Philips | ANUBIS-S | Distortion of sound | Replace C2102 by 4n7 (4822 126 12641)
Add R3130 56k (4822 116 52291)
Add R3136 39k (4822 020 23903)
at pin 1 of IC7225-6F audio part
REMARKS :
Introduced in production week 9331
| 14-09-04 |
Philips | ANUBIS-S | Double image (only for 54/71/77/85/87 sets) | Delete C2286, C2287 and C2288 at the outputs of the video
controller IC7225-6D
REMARKS :
Introduced in production week 9333
| 14-09-04 |
Philips | ANUBIS-S | Failure of TS7513 for 21" ANUBIS-S BB /93 | In order to reduce the voltage accross the drain source of TS7513
it is recommended to:
Replace R3526 by 47k 5% 4822 053 11473
Place 2 beads (4822 526 10609) between anode D6530 and D6531 (at
the secondary side of the power supply) and the PWB at the c | 14-09-04 |
Philips | ANUBIS-S | Failure of TS7513 for 21" ANUBIS-S BB /93 | In order to reduce the voltage accross the drain source of TS7513
it is recommended to:
Replace R3526 by 47k 5% 4822 053 11473
Place 2 beads (4822 526 10609) between anode D6530 and D6531 (at
the secondary side of the power supply) and the PWB at the c | 14-09-04 |
Philips | ANUBIS-S | Failure on Line Output Transistor TS7445 | In case of a failure on the Line Output Transistor TS7445 in
Anubis S CC, it is recommended to adapt the circuitry as follows
(see diagram A page 7 service manual Anubis S CC)
(GB 4822 727 20288 and ES 4822 727 20289)
* Delete Scan Protection Panel
* Cha | 14-09-04 |
Philips | ANUBIS-S | Failure on Line Output Transistor TS7445 (2SC379X) | In case of failure of the Line Output Transistor TS7445, it is
recommended to adapt the circuitry as follows:
For 14" Anubis S AA sets:
* change TS7445 into BU1508DX (4822 130 63569)
* delete R3445
* change R3444 into 4k7 5% | 14-09-04 |
Philips | ANUBIS-S | For all ANUBIS-S AA (PV2) sets
Failure of IC7400 | For all ANUBIS-S AA (PV2) sets
Failure of IC7400 frame deflection after protection
---------------------------------------------------
If IC7400 is damaged after an activation of the internal protection
circuitry inside IC7400 it is recommended to:
Add | 14-09-04 |
Philips | ANUBIS-S | Geometrical distortion at teletext reception | In case of some degree of distortion at teletext reception,
it is recommended to:
change R3828 to 1k 5% 0.25W SMD 4822 051 10102
REMARKS :
Sensitivity of the horizontal deflection can be effected by
different beam current, especially a | 14-09-04 |
Philips | ANUBIS-S | Horizontal flashing lines across picture in VHF 1 at certain volume | At the stereo playback panel (diagram G Anubis S AA manual
4822 727 19707 in GB and 4822 727 19719 in E) it is recommended to:
Add 2n2 10% 50V (4822 122 33531) at junction 2893/3891
and pin 2 S18
Add 2n2 10% 50V (4822 | 14-09-04 |
Philips | ANUBIS-S | How to activate "Hotel mode" | Applicable for family: VST sets
For AA/BB/CC sets
Identification on uP:
Hotel mode can only be activated if the software for hotel mode
is available (so an "H" version) and when the hotel mode option
(address 246) is enabled. Two hotel modes are possible | 14-09-04 |
Philips | ANUBIS-S | How to activate "Hotel mode" | Applicable for family: PLL sets
For AA/BB/CC sets
Identification on uP:
Hotel mode can only be activated if the software for hotel mode
is available (so an "H" version) and when the hotel mode option
(address 246) is enabled. Only one hotel modes is poss | 14-09-04 |
Philips | ANUBIS-S | How to activate "Hotel mode" | Applicable for family: VST sets
For DD sets
Identification on uP:
Hotel mode can only be activated if the software for hotel mode
is available (so an "H" version) and when the hotel mode option
(address 246) is enabled. Two hotel modes are possible:
Hot | 14-09-04 |