Sharp
DV5131 S3B
Int won't come out of st/by with LED flashing
R745 0R33 risen slightly - To adjust the B+ set R739 for 14 volts on D712
14-09-04
Sharp
DV5131 S3B
St/by only ; 5v & 12v supplies not being sw on by Q703 & Q707
Fusible R744 o/c - replacing it only restored 12v - check D732 & 733, one was nearly o/c
14-09-04