File information: | |
File name: | SC_Audible_plops_at_switch_off_Rework_instructions.pdf [preview SC Audible plops at switch off Rework instructions] |
Size: | 698 kB |
Extension: | |
Mfg: | Philips |
Model: | SC Audible plops at switch off Rework instructions 🔎 |
Original: | SC Audible plops at switch off Rework instructions 🔎 |
Descr: | Philips Symptom Cure 2006 References SC_Audible_plops_at_switch_off_Rework_instructions.pdf |
Group: | Electronics > Other |
Uploaded: | 04-04-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name SC_Audible_plops_at_switch_off_Rework_instructions.pdf 1. LC4.6E: Audible plop when switching "off" the set. 1.1. Rework Instructions On the SSB: 3 1 470R 2k2 B 2 E_14780_142.eps 130704 1) Remove SMD resistor 3702. 2) Mount a (leaded) resistor of 2k2 between the base of 7714 and pin 5 of 7709. 3) Mount a (leaded) resistor of 470R between the base of 7714 and pin 3 of 7709. 4 E_14780_143.eps 120704 4) Mount a wire between pin 3 of 5735 and 4720 (at connector 1702 side). |