File name avs-04_022-DVP5_SW_upgrade_.pdf A. Preparation to upgrade firmware: 1. Unzip the zip-archive attached to this service information 2. Start the CD Burning software and create a new CD project (data disc) with the following settings: File system: ISO9660 Format: MODE 1: CDROM Recording mode: SINGLE SESSION (TRACK-AT-ONCE), FINALIZED CD 3. Place the content of the zip-archive (1 file) into the root directory of the new CD project. 4. Change the CD Volume Label to: DVP5XX 5. Burn the data onto a blank CDR Note: ISO9660 is mandatory, UDF discs are not supported ! The final CDROM must not contain any other data except the file from the zip-archive. B. Procedure to apply the firmware upgrade: 1. Power up the set and open tray. 2. Insert the prepared upgrade CD-ROM and close the tray. 3. The set will start reading and detect the firmware upgrade file on the disc. Folowing messages are shown on the TV screen: - Upgrade file detected - Upgrade ? - Press Play to start 4. Press |