File name As99-07.pdf For internal use only PHILIPS ISSUE AS99.07 (99-09-28) Published by: Service Department Audio Systems LINE OF BUSINESS AUDIO SYSTEMS SERVICE NEWSLETTER 07.01 TYPENUMBER(S): FW350C/34, FW390C/34, FW398C/34 SYMPTOM : IRIS CODE 1 2 1 2 FM1 range is lost when the set is switched off. CURE : The FM1 range (65.81-74MHz) can be turned on via the procedure published in Service Newsletter AS99.05.03. However, due to a software problem, some sets disable the FM1 range again when the set is switched off. The problem can be resolved by replacing the microprocessor by the new version "23". The ordering code reads 9965 000 01676. REMARKS : 07.02 TYPENUMBER(S): FW754P, FW765P, FW795W INFORMATION : Corrections to the Service Manual, partslist 1. Service code for Rucksack of "Power4 Module" should read: 4822 256 10575 Rucksack 4 Channel 2. FW795W/37 only: Service code for item 224 (Exploded view, page 14-2) should read: 4822 454 13447 Orn Display DPL only for FW795W/37 REMARKS : Service Newsletter 1999 |