datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:panasonic isolating sc su sd 2009 pdp

panasonic isolating sc su sd 2009 pdp free download

Various electronics service manuals

File information:
File name:isolating_sc_su_sd_2009_pdp.pdf
[preview isolating sc su sd 2009 pdp]
Size:95 kB
Extension:pdf
Mfg:panasonic
Model:isolating sc su sd 2009 pdp 🔎
Original:isolating sc su sd 2009 pdp 🔎
Descr: panasonic Plasma TV TX-P42G10B isolating_sc_su_sd_2009_pdp.pdf
Group:Electronics > Other
Uploaded:11-04-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name isolating_sc_su_sd_2009_pdp.pdf

CONFIDENTIAL DOCUMENT TYPE Service Hints DOCUMENT TITLE Isolating SC, SU and SD PCBs on 2009 PDP models REV 16.7.09.v1.00..ss APPLICABLE All 2009 pdp models; C, X, S, G, V, X, Z SERIES MODELS PAGE 1. Index 2. Service hints for 6 and 7 blinks error codes on 2009 pdp models i. Isolating SC, SU/SD PCBs ii. Testing SU/SD boards 3. Location of Vfg test point for checking SU/SD boards 1 CONFIDENTIAL 2009 PDP Service Hints: 1. For 7 blinks (floating side error> SU/SD suspect): SU and SD PCBs cannot be isolated in turn (as could be done on older models) since this can lead to other PCBs becoming damaged. Both the SU and SD PCBs must be isolated together from SC PCB and SC50 connector pins shorted out using an insulated croc clip or the dedicated connector jig shown (P/N TZSC09187) 2. See slide below for how to isolate the SU and SD PCBs. The guide also shows how to test the SU or SD pcbs if they are found to be the cause of shut down. 3. For 6 blink problems (energy recovery error> SC suspect): For 2009 HD resolution models: X10 or C10. These models do not allow the disconnection of SC PCB as it may lead to SS PCB damage. For these basic models, if a scan board blink error still exists after carrying out step 1 then a new scan board must be tried. NOTE: FHD 2009 models (S, G, V and Z series) can have the SC PCB totally isolated (unplugged) without the need to try a new one. Identification and Jig introduction for Scan Drive Circuit problem 1. Diagnosis for SC board or SU/ SD board. On '09 PDP models, a service jig (TZSC09187) can be used to identify if SC or SU/ SD board is defective. The procedure is as follows. SC JIG TZSC09187) 1) Disconnect SU and SD board from SC board. (*1) 2) Connect a Jig (TZSA09187) to the connector "SC50" on SC board. (*2) 3) Check the front LED condition after Power on. (*3) SC50 LED Condition Defective PCB Lit (Normal) SU or SD board are defective Blinking SC board is defective (*1) There is no need to disconnect FPCs (panel's flex

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
panasonic Tv009 - panasonic DSD0810051CE - panasonic sm pt-lb412 lb382 lb332 lw362 lw312 - panasonic MQM00088TR310714REV3 NRB32SW1 Ice Formed On Damper - panasonic PCZ1602009CE - panasonic PAPAMY1607071CE - panasonic PCZ1702028CE -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Techno 29 TS-7212

script execution: 0.06 s