File name As99-01.pdf For internal use only PHILIPS ISSUE AS99.01 (99-02-12) Published by: Service Department Audio Systems LINE OF BUSINESS AUDIO SYSTEMS SERVICE NEWSLETTER 01.01 TYPENUMBER(S): CDC751, CDC752 INFORMATION : During transportation the pin on the Crank (pos 96) might jump out of the groove on the Tray (pos 108). From production wk9835 onwards, the Tray and Crank have been modified. The groove on the tray is now deeper and likewise the pin on the Crank is 3mm longer. Due to this change the new Crank does not fit into the old Tray anymore. But it is still possible to use the old Crank on the new Tray. The service code numbers for the Cranks are as follows: 4822 535 40105 Old Crank 4822 402 11241 New Crank Service Newsletter 1999 |