File name c9psect.pdf Error Diagnosis Contents Description of error Automatic FL Display Remarks Code F61 The abnormalities In normal operation, when DCDET2 goes Press [ STOP] on main in an output or power to "L" (Low) (Not during POWER OFF unit for next error. supply circuit of condition), F61 appears on FLDisplay SMPS P.C.B. for 1 second and PCONT goes to "L" (Low).This is due to speaker output has DC voltage or fan is not working. F76 Abnormality in the In normal operation when DCDET1 is Press [ STOP] on main output voltage of detected "L" (Low) for two consecutive unit for next error. stabilized power times, F76 is displayed on FL for supply 1 second and after that PCONT will be turned to "L" (Low). This is due to any of the DC voltages (+9V, +7V, -7V, +5V, +5.3V etc.) not available. |