File name p08-15.pdf8 104S CM23 GSIII Electrical Instructions
Go to cover page
0. General: 2. EHT voltage (3540)
When carrying out the electrical setting, in many cases a video - Connect a dc voltmeter between capacitor 2643 joint and ground.
signal must be applied to the monitor. A computer with : - Apply a video signal in the 640 x 480 with 31.5 kHz/60 Hz mode.
- Select the "crosshatch" pattern. Adjust trimming pot-meter 3540
- "ATI VGA1024" interface card until the DC voltmeter reads : 67.5 +/- 0.2V (for PHILIPS CRT),
- PGA1024 (4822 212 30916) But 68 V for CPT CRT
- PGA1280 (4822 212 30917)
3. Monitor the following auxiliary voltages
are used as the video signal source. The signal pattern are selected
from the "service test software" package. see user guide 4822 727 +12V source across C2158 +12.7V +/- 0.5 VDC
19896 (ATI 1024), or 4822 727 20273 (PGA 1280). - 12V source across C2162 - 12.7V +/- 0.5 VDC
+8V source across C2172 +8.0V +/- 0.4 VDC
+6V source across C2164 +6.2V +/- 0.3 VDC
0.1 Factory preset timing mode -178V source across C2647 -178V +/- 8.0 VDC
+180V source across C2153 +183V +/- 1.5 VDC
+5V source across C2168 +5.0V +/- 0.25VDC
Resolution H.freq./V.freq. H. V. +80V source across C2156 +81.0 V +/- 0.5 VDC
640 x 400 31.5 kHz/70 Hz - +
640 x 480 31.5 kHz/60 Hz - - 4. General conditions for alignment
640 x 480 37.5 kHz/75 Hz - -
800 x 600 46.9 kHz/75 Hz + + 4.1 During all alignments, supply a distortion free AC mains voltage
800 x 600 53.7 kHz/85 Hz + + to set via an isolating transformer with low internal impedance.
1024 x 768 48.3 kHz/60 Hz - - 4.2 Align in pre-warmed condition, at least 30 minutes warm-up with
nominal picture brightness.
4.3 Purity, geometry and subsequent alignments should be carried
out in magnetic cage with correct magnetic field.