datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:AVO avo8-instruction-plates

AVO avo8-instruction-plates free download

Various electronics service manuals

File information:
File name:avo8-instruction-plates.pdf
[preview avo8-instruction-plates]
Size:143 kB
Extension:pdf
Mfg:AVO
Model:avo8-instruction-plates 🔎
Original:avo8-instruction-plates 🔎
Descr: . Rare and Ancient Equipment AVO avo8-instruction-plates.pdf
Group:Electronics > Other
Uploaded:08-07-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name avo8-instruction-plates.pdf

UNIVERSAL AVOMETER WORKING INSTRUCTIONS MODEL 8. IMPORTANT GENERAL To ensure accurate readings, the meter should be used face upwards. If necessary, set the pointer to instrument zero by means of the screw on the face of the panel. The lower pair of terminals should be used for all ranges on the switch knobs, the left-hand terminal being common for the 2500V. range also. When in doubt, always use the highest range and work downwards, there being no necessity to disconnect the supply. Never switch off current or voltage by rotating either switch to a blank position. The polarity shown at the terminals is correct for normal use, but a movement reversing switch marked "REV. M.C." is provided to facilitate certain tests. The automatic overload cut-out, if tripped, interrupts the main circuit and except in cases of abnormal overload, it provides complete immunity from damage. If it operates, disconnect the leads from supply, reset the cut-out with the meter horizontal, and clear the fault before reconnecting the leads. Since mechanical shock may cause it to trip, handle the meter carefully. If the meter is used on circuits in excess of 2500 V., it should be kept at the earthy end of the circuit or alternative precautions taken. The instrument itself has been tested at 6000 V., A.C., but special care should always be taken when testing high voltage circuits. Ensure that the leads are maintained in good condition. The resistance of the leads is approximately 0.02 ohms per pair. A copper oxide rectifier is incorporated for A.C. measurements, the calibration being correct for a sinusoidal input or for one of equivalent form factor (1.11). The decibel scale may be used with any A.C. current or voltage range. When comparing readings on different ranges, add 8 dB to pointer indication for each increase of 2

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
AVO sm-ct163 - AVO TYPE160service - AVO AVO VCMMkIII - AVO CT160 2 - AVO CT160 1 - AVO AVO AllWaveOscillator - AVO spa -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Samsung MAX460

script execution: 0.25 s