File information: | |
File name: | SONY DSR-PD150.pdf [preview DSR-PD150] |
Size: | 7463 kB |
Extension: | |
Mfg: | Sony |
Model: | DSR-PD150 🔎 DSRPD150 |
Original: | DSR-PD150 🔎 |
Descr: | Sony SONY DSR-PD150.pdf |
Group: | Electronics > Other |
Uploaded: | 13-04-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name SONY DSR-PD150.pdf DSR-PD150/PD150P RMT-811 SERVICE MANUAL Ver 1.2 2001. 03 US Model Canadian Model DSR-PD150 AEP Model DSR-PD150P Photo : DSR-PD150 C MECHANISM NTSC model : DSR-PD150 PAL model : DSR-PD150P SPECIFICATIONS -- Continued on next page -- DIGITAL CAMCORDER SERVICE NOTE 1. POWER SUPPLY DURING REPAIRS In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so that the unit cannot operate. These following two methods are available to prevent this. Take note of which to use during repairs. Method 1. Connect the servicing remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the commander switch to the "ADJ" side. Method 2. Use the DC IN terminal. (Use the AC power adaptor. (AC-L10, AC-VQ800 etc. )) 2. TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT) 1 Refer to 2-3. to remove the upper handle block assembly. 2 Refer to 2-5. to remove the cabinet (L) assembly. 3 Refer to 2-5. to remove the mechanism deck (Including VC-242D board and DD-138D board). 4 Remove DD-138D board from the mechanism deck (Including VC-242D board). 5 Remove the CN022 (27P 0.3 mm) of VC-242D board. 6 Supply +4.5V from the DC power supply to the loading motor and unload with a pressing the cassette compartment. DC power supply (+4.5V) : loading : unloading Disconnect from CN022 (27P) of VC-242D board. Loading motor What to do when a user forgets a password This camcorder has the forced log insertion function. A password is inputted, and this function is set up. When this function was set up, this camcorder doesn't move if the memory stick which memorize a correct logo isn't inserted. To release the forced logo function, the correct password must be input. This password is memorized in the IC1105 (EEPROM) on VC-242D board. Therefore, when a user forgets the password, replace the IC1105. This IC1105 memorizes the HRS METER data (Hour meter data: page A, address 00 to 13), too. Therefore, replace the IC1105 in the following order to copy the HRS METER data. Replacing procedure: 1) Note down the data of page A, address 00 to 13. 2) |
Date | User | Rating | Comment |