File information: | |
File name: | NX-300_K5_K.6_TA.pdf [preview NX-300 K5 K.6 TA] |
Size: | 1663 kB |
Extension: | |
Mfg: | Kenwood |
Model: | NX-300 K5 K.6 TA 🔎 |
Original: | NX-300 K5 K.6 TA 🔎 |
Descr: | Kenwood Radios NX-300_K5_K.6_TA.pdf |
Group: | Electronics > Radio stations > Radios |
Uploaded: | 25-05-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name NX-300_K5_K.6_TA.pdf 1/12 ADJUSTMENT Common Section Measurement Adjustment Test- Item Condition equipment Unit Terminal Unit Parts Method Specifications/Remarks 1. Setting 1) BATT terminal voltage:7.5V 2) SSG standard modulation [Wide] MOD:1kHz,DEV:3kHz [Narrow] MOD:1kHz,DEV:1.5kHz 2. LCD contrast 1) Adj item:[CNTR] [U1] Adjust the LCD contrast by Adjust:[***] [D1] looking. Press [P3] key to store the adjustment value. 3. Counter 1) Adj item:[VOL1] Turn the Volume clock-wise Adjust:[***] counter-clockwise fully. Press volume [P3] key to store the adjustment value. 4. Clock-wise 1) Adj item:[VOL2] Turn the Volume clockwise volume Adjust:[***] fully. Press [P3] key to store the adjustment value. 5. Assist voltage 1) Adj item:[RAST] [U1] The display on the left of [RX] Adjust:[***] [D1] LCD shows PLL lock voltage. 2.5V |