File name SB-2MC-0003-B379.pdf(Page.1/2)
Service Bulletin Ref. No. 2MC-0003 (B379)
November 14, 2011
Firmware Upgrade (Engine: Ver.003.002; FAX: Ver.007.001;
Subject Scanner: Ver.003.001)
FS-3540MFP_FS-3640MFP_v03.00.0030_(2011-07-11)
Model FS-3540MFP, FS-3640MFP
Topic
The firmware was upgraded as follows.
Content of Changes
No. Item Details CTL FW
1 Measures against the The toner low detection was changed according to the residual amount 575685 ENGINE
erroneous display of since "Toner low" might be displayed right after toner container was
"Toner low" message installed.
(Indication of "Toner low" message is based on the count where the toner
low is regularly detected. However, if the amount of residual toner inside
the toner container is high, the count to show this message will be
increased in order to stabilize the toner low detection.)
2 Change of the SC5100 The SC5100 error detection was changed to the same manner as for the 571973 ENGINE
error detection conventional models.
3 Change of the adjustment The waiting time before the blackness reference data reception was 571255 SCA
waiting time changed from 50msec to 150msec.
*If the mode shift is not enabled, unnecessary lamp ON/OFF will be
omitted.
The following change was implemented since the engine firmware of this version. Please explain it to your
users.
"The toner container once showed cannot be reused even if reinstalling it to the machine.
Please replace it with a new toner container."
Check Current
Program No. SUM Ver. Status Date Ver. Remark
ENGINE 2MC_1000003002 83E0 003.002 2011/10/14 002.001 New upgrade
MAIN 2MC_2F00003024 003.024 - - FS-3540MFP
MAIN 2MD_2F00003024 003.024 - FS-3640MFP
SCANER 2MC_1200003001 A087 003.001 2011/8/10 002.001 New upgrade
MMI 2MC_7000003020 - 003.020 - -
Optional language 2MC_81BR001006 - 001.006 - - For KMBR
BR
FAX BOOT/APL 2KX_5500007001 - 007.001 - 0 |