File name 1155037.PDF MINOLTA CO., LTD., SERVICE ENGINEERING DIVISION PAGE NO. : 1/2 SERVICE BULLETIN PROBLEM FUNCTION SAFETY SERVICEABILITY OTHERS MODEL NAME : Di620 OTHERS PERFORMANCE CORRECTION SAFETY REGULATION OTHERS MODEL CODE : 1155 NO. : 037 DATE : 990609 SUBJECT : NOISE FROM THE CLEANING UNIT PROBLEM: Noise can at times occur from the Cleaning Unit drive mechanism. CAUSE: Variations in accuracy of the drive gear and associated parts result in varying distances between the shaft of the Toner Conveying Coil gear and that of gear A (that transmits drive from PC Drum Drive Motor M2). SOLUTION: The following changes have been made: 1. A Toner Conveying Coil fixing holder (01) has been added. 2. A hole (3.7mm) has been drilled into the mounting bracket (02) that is used to secure the holder (01). 3. The dimensions of the Toner Conveying Coil (03) and the shaft on which gear A is mounted have been changed. NOTE: The new gear A mounting shaft is valid effective with machines starting with Se/No. |