datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Kenwood B51-8641-00-EVPL2

Kenwood B51-8641-00-EVPL2 free download

Various electronics service manuals

File information:
File name:B51-8641-00-EVPL2.pdf
[preview B51-8641-00-EVPL2]
Size:1507 kB
Extension:pdf
Mfg:Kenwood
Model:B51-8641-00-EVPL2 🔎
Original:B51-8641-00-EVPL2 🔎
Descr: Kenwood UHF FM Transceiver UHF FM Transceiver Kenwood TK-3107 B51-8641-00-EVPL2.pdf
Group:Electronics > Other
Uploaded:15-07-2022
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name B51-8641-00-EVPL2.pdf

TK-3107 ADJUSTMENT / Required Test Equipment 1. Stabilized Power supply 1. The supply voltage can be changed between 5V and 18V, and the current is 3A or more. 2. The standard voltage is 7.5V. 2. DC Ammeter 1. Class 1 ammeter (17 ranges and other features). 2. The full scale can be set to either 300mA or 3A. 3. A cable of less internal loss must be used. 3. Frequency Counter (f. counter) 1. Frequencies of up to 1GHz or so can be measured. 2. The sensitivity can be changed to 500MHz or below, and measurements are highly stable and accurate (0.2ppm or so). 4. Power Meter 1. Measurable frequency : Up to 500MHz 2. Impedance : 50 , unbalanced 3. Measuring range : Full scale of 10W or so 4. A standard cable (5D2W 1m) must be used. 5. RF Voltmeter (RF V.M) 1. Measurable frequency : Up to 500MHz or so. 6. Linear Detector 1. Measurable frequency : Up to 500MHz or so 2. Characteristics are flat, and CN is 60dB or more. 7. Digital Voltmeter 1. Voltage range : FS=18V or so 2. Input resistance : 1M or more 8. Oscilloscope 1. Measuring range : DC to 30MHz 2. Provides highly accurate measurements for 5 to 25MHz. 9. AF Voltmeter (AF V.M) 1. Measurable frequency : 50Hz to 1MHz 2. Maximum sensitivity : 1mV or more 10. Spectrum Analyzer 1. Measuring range : DC to 1GHz or more 11. Standard Signal Generator (SSG) 1. Maximum frequency : 500MHz or more 2. Output : -133dBm/0.05

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Kenwood B51-7901-00 - Kenwood B51-7901-00(1-TXT) - Kenwood B51-7901-00(3-SD) - Kenwood B51-7901-00(4-EVPL) - Kenwood B51-7966-00 - Kenwood B51-7966-00-SD - Kenwood B51-7966-00-TXT -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Grundig Satellit 600

script execution: 0.04 s