Now downloading free:cyrix Application Note 130 III CPU Layout Guidelines for 133 MHz Bus Operation

cyrix Application Note 130 III CPU Layout Guidelines for 133 MHz Bus Operation free download

Various electronics service manuals

File information:
File name:Application Note 130 Cyrix III CPU Layout Guidelines for 133 MHz Bus Operation.PDF
[preview Application Note 130 III CPU Layout Guidelines for 133 MHz Bus Operation]
Size:83 kB
Extension:PDF
Mfg:cyrix
Model:Application Note 130 III CPU Layout Guidelines for 133 MHz Bus Operation 🔎
Original:Application Note 130 III CPU Layout Guidelines for 133 MHz Bus Operation 🔎
Descr: cyrix Application Note 130 Cyrix III CPU Layout Guidelines for 133 MHz Bus Operation.PDF
Group:Electronics > Other
Uploaded:08-09-2022
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name Application Note 130 Cyrix III CPU Layout Guidelines for 133 MHz Bus Operation.PDF

Application Note 130 Cyrix III CPU Layout Guidelines for 133 MHz Bus Operation Cyrix Processors REVISION HISTORY Date Version Revision 3/31/99 0.3 Page 4 Added paragraph under Introduction. 3/29/99 0.2 Removed notes 3 and 4 from Table 3. Restored subscripts on page 7. Minor typos corrected on page 27. 2/18/99 0.1 Initial Version C:\documentation\joshua\appnotes\cIII_layout.fm Table of Contents 1.0 Introduction 4 2.0 Printed Circuit Board Stack-Up 5 3.0 GTL+ Bus Timing Analysis 7 4.0 Clock Layout Recommendations 13 5.0 GTL+ Layout Recommendations 17 6.0 Differences between Cyrix III and IntelTM CeleronTM Design Guides 27 Cyrix Application Note 130 - Cyrix III Layout Guideline for 133 MHz Operation 3 APPLICATION NOTE 130 Cyrix III Layout Guideline for 133 MHz Operation 1 Introduction The Cyrix III processor is a next generation Cyrix processor. Cyrix III employs a Socket 370 package, P6 bus protocol and operates with front side bus speeds of 66 MHz, 100 MHz, and 133 MHz. The Cyrix III processor system bus uses GTL+ signaling interface. The objective of this layout guideline is to provide the system designer with the information needed to achieve stable operation with 133 MHz front side bus. A Cyrix III IBIS model is available if the system designer would like to verify his design, but signal integrity analysis is not a requirement if the design falls within the specifications of this guideline. This document is to serve as a reference design to help new board designers meet the 133 MHz specification. The Guidelines in this document are for reference only, and are not a requirement for Cyrix motherboard certification. 4 Cyrix Application Note 130 - Cyrix III Layout Guideline for 133 MHz Operation 2. Printed Circuit Board Stack-Up Either a four-layer or six-layer stack-up can be used. In either case, it is important to control the characteristic impedance to be 60 ohms within +/-10% for a 6 mil-wide trace. This characteristic impedance improves signal integrity in many respects. Firstly, it improves signal integrity because it is close to the value of the termination, 56 ohms. Secondly, it reduces overshoots and under- shoots. Table 1 and Figure 1 describes a four-layer stack-up which would meets the characteristic impedance require

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
cyrix M1-2 - cyrix M1-4 - cyrix Application Note 116 Performance Rating the M II-300 Processor - cyrix CPU Detection Guide - cyrix M1-6 - cyrix III Processor DataBook - cyrix M1-1 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Westpoint WMW-61013.ER

script execution: 0.01 s