File information: | |
File name: | How-To-Update-A20-From-MKII-To-MKIII.pdf [preview A-20 MK II] |
Size: | 767 kB |
Extension: | |
Mfg: | Primare |
Model: | A-20 MK II 🔎 |
Original: | |
Descr: | How-To-Update-A20-From-MKII-To-MKIII |
Group: | Electronics > Consumer electronics > Audio |
Uploaded: | 06-06-2024 |
User: | rgorjao |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name How-To-Update-A20-From-MKII-To-MKIII.pdf How To Update A20 From MKII To MKIII Make sure the amplifier is not connected to the mains. Take the top-cover off the amplifier. Locate and change the following components: R5, R105 to 280R R1, R101 to 380R R2, R4 to 7,5K R36, R136 to 620R C19, C119 to 470pF The seize is either 0805 or 1206 depending on the age of the amplifier. The pictures is applying on 0805. On the 1206 variant they are located a bit different, check Service Manual. After this is done, power up the amplifier and check that it works. Power it off and remove the two Shortlinks on the board, power it up again and let it be warm. (Just let it run without any signal for half an hour). Measure the bias on the pins where the shortlinks where located, you should adjust it With the potentiometer to 13mVon each channel. Recheck after another half an hour. Power it off and refit the shortlinks. Refit the cover. Now you are done! Overwiev of the A20 Bias Trimmer Shortlink Left Shortlink Right Bias Trimmer Left Channel Channel Channel Right Close Look Right Channel Temporarily remove the heatsink on REG2 R136 C119 R4 R101 Close look Left Channel R105 R5 C19 R1 //Björn Holmqvist Primare Systems AB |