File information: | |
File name: | NEO TV-2188TXSF +SM VCT3831A.rar [preview TV-2188TXSF] |
Size: | 400 kB |
Extension: | rar |
Mfg: | NEO |
Model: | TV-2188TXSF 🔎 TV2188TXSF |
Original: | |
Descr: | VCT3831A |
Group: | Electronics > Consumer electronics > TV |
Uploaded: | 08-05-2008 |
User: | emoome |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 2 | |
File name NEO TV-2188-SM.pdf Process Document Inspection Process Card Inspection Items KONKA GROUP CO, LTD Product Nam e Product Type Procedure Name Procedure No. 21"Color Television Set K2107ASTN K2107ASTN-TS NO. 1 2 3 4 5 6 7 8 9 10 11 NO. 1 2 3 4 5 6 7 8 9 10 11 NO. 1 2 3 NO. 1 2 3 FAC3 MSP USED Window Mode Side AV Av out Fixed Alps Used HDEV3 used Fast Tune Tele-text Language 6.5M L AUTO SCART FAC4 AUDIO ONLY TILT ADJUSTMENT SVM ADJUSTMENT REAL TIME CLOCK CHILD CLOCK YCbCr AVC BLANK BLANK BLANK BLANK FAC6 R-Cutoff ref G-Cutoff ref B-Cutoff ref FAC7 R-Drive ref G-Drive ref B-Drive ref Inspection content and method DATA YES YES YES NO Factory menu data inspection Enter factory service menu Press MENU button of remote handset to display the menu, then press RECALL button 5 times to enter factory service menu. Then Press 3 button enter FAC3; Press 4 button enter FAC4 Press 6 button enter FAC6; Press 7 button enter FAC7; Press 8 button enter FAC8; Press 9 button enter memory data; Press LAN button enter FAC LAN. After finish, press 0 button, then RECALL button to exit factory mode. <(6 NO NO YES ALL NO YES DATA NO NO NO NO YES NO ü Initial DATA 128 128 128 Initial DATA 128 128 128 NO. 1 2 3 4 5 6 7 8 9 10 11 NO 1 2 3 4 5 FAC8 CONTRAST MIN CONTRAST MID CONTRAST MAX BRIGHT MIN BRIGHT MID BRIGHT MAX COLOR MIN COLOR MID COLOR MAX CVBS-2 SVHS FAC LAN VOL 1 VALUE VOL 10 VALUE VOL 40 VALUE VOL 70 VALUE VOL 99 VALUE DATA 22 70 85 0 25~35 50 0 70 80 NO NO DATA 20 80 110 115 125 Changing Marks Quantity Changing Sheet No. Signature Date Approved by 2004 8 5 Standardized by 2004 8 5 § § Checked by 2004 8 5 £ £ Prepared by ©© ¨ ¦ ¥ ¤ ¢ ¡ Apparatus and tool Work-type Remote handset: KK-Y267 Man-hour 2004 8 5 K2107ASTN-TS -GJC Edition 0 Page1 of 2 Process Document Inspection Process Card Inspection Items KONKA GROUP CO, LTD Product Nam e Product Type Procedure Name Procedure No. 21"Color Television Set K2107ASTN K2107ASTN-TS Factory menu data inspection Press 9 button to check every address data in E2PROM. will and the following data should be right. Inspection content and method Apparatus and tool Ä Å $''5 '$7$ $''5 '$7$ $''5 '$7$ $''5 '$7$ $''5 '$7$ $''5 '$7$ Remote handset: KK-Y267 address=0~511 in memory can not be changed at Work-type Man-hour ! ! hanging Marks Quantity Changing Sheet No. Signat | ||
File name NEO TV-2188TXSF-01.pdf | ||
File name NEO TV-2188TXSF-02.pdf | ||
File name NEO TV-2188TXSF-ServiceMode.PDF Process Document Inspection Process Card Inspection Items KONKA GROUP CO, LTD Product Nam e Product Type Procedure Name Procedure No. 21"Color Television Set KP2107ASTN KP2107ASTN-TS NO. 1 2 3 4 5 6 7 8 9 10 11 NO. 1 2 3 4 5 6 7 8 9 10 11 NO. 1 2 3 NO. 1 2 3 FAC3 MSP USED Window Mode Side AV Av out Fixed Alps Used HDEV3 used Fast Tune Tele-text Language 6.5M L AUTO SCART FAC4 AUDIO ONLY TILT ADJUSTMENT SVM ADJUSTMENT REAL TIME CLOCK CHILD CLOCK YCbCr AVC BLANK BLANK BLANK BLANK FAC6 R-Cutoff ref G-Cutoff ref B-Cutoff ref FAC7 R-Drive ref G-Drive ref B-Drive ref Inspection content and method DATA YES YES YES NO Factory menu data inspection Enter factory service menu Press MENU button of remote handset to display the menu, then press RECALL button 5 times to enter factory service menu. Then Press 3 button enter FAC3; Press 4 button enter FAC4 Press 6 button enter FAC6; Press 7 button enter FAC7; Press 8 button enter FAC8; Press 9 button enter memory data; Press LAN button enter FAC LAN. After finish, press 0 button, then RECALL button to exit factory mode. <(6 NO NO YES ALL NO YES DATA NO NO NO NO YES NO ü Initial DATA 128 128 128 Initial DATA 128 128 128 NO. 1 2 3 4 5 6 7 8 9 10 11 NO 1 2 3 4 5 FAC8 CONTRAST MIN CONTRAST MID CONTRAST MAX BRIGHT MIN BRIGHT MID BRIGHT MAX COLOR MIN COLOR MID COLOR MAX CVBS-2 SVHS FAC LAN VOL 1 VALUE VOL 10 VALUE VOL 40 VALUE VOL 70 VALUE VOL 99 VALUE DATA 22 70 85 0 25~35 50 0 70 80 NO NO DATA 20 80 110 115 125 Prepared by Checked by Standardized by Changing Marks Quantity Changing Sheet No. Signature Date Approved by © §¨§ ¦ ¥ ¤ £ ¢ ¡ Apparatus and tool Work-type Remote handset: KK-Y267 Man-hour 2004.7.26 2004.7.26 2004.7.26 2004.7.26 KP2107ASTN-TS -GJC Edition 1 Page1 of 2 Process Document Inspection Process Card Inspection Items KONKA GROUP CO, LTD Product Nam e Product Type Procedure Name Procedure No. 21"Color Television Set KP2107ASTN KP2107ASTN-TS Factory menu data inspection Press 9 button to check every address data in E2PROM. address=0~511 in memory can not be changed at will and the following data should be right. Inspection content and method Apparatus and tool Ä Å'$7$ $''5 '$7$ $''5 '$7$ $''5 '$7$ $''5 '$7$ $''5 '$7$ $''5 $ % & ' ( Remote handset: KK-Y267 Work-type Man-hour Checked by Standardized by Quantity Changing Sheet No. Signature Date Approved by hanging Mark |
Date | User | Rating | Comment |