datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:samsung samsung

samsung samsung free download

Air conditioning and climatization devices

File information:
File name:samsung air.pdf
[preview samsung]
Size:2005 kB
Extension:
Mfg:samsung
Model:samsung 🔎
Original:ps21245 🔎
Descr:ps21245 samsung
Group:Electronics > Consumer electronics > Air conditioning
Uploaded:12-02-2009
User:sliwen
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name samsung air.pdf

ROOM AIR CONDITIONER INDOOR UNIT SH12VCD SH09VCD OUTDOOR UNIT SH12VCDX SH09VCDX SERVICE AIR CONDITIONER Manual CONTENTS 1. Precautions 2. Product Specifications 3. Operating Instructions and Installation 4. Disassembly and Reassembly 5. Troubleshooting 6. Exploded Views and Parts List 7. PCB Diagrams 8. Wiring Diagrams 1. Precautions 1. Warning: Prior to repair, disconnect the power cord from the circuit breaker. 2. Use proper parts: Use only exact replacement parts. (Also, we recommend replacing parts rather than repairing them.) 3. Use the proper tools: Use the proper tools and test equipment, and know how to use them. Using defective tools or test equipment may cause problems later-intermittent contact, for example. 4. Power Cord: Prior to repair, check the power cord and replace it if necessary. 5. Avoid using an extension cord, and avoid tapping into a power cord. This practice may result in malfunction or fire. 6. After completing repairs and reassembly, check the insulation resistance. Procedure: Prior to applying power, measure the resistance between the power cord and the ground terminal. The resistance must be greater than 30 megaohms. 7. Make sure that the grounds are adequate. 8. Make sure that the installation conditions are satisfactory. Relocate the unit if necessary. 9. Keep children away from the unit while it is being repaired. 10. Be sure to clean the unit and its surrounding area. Fig. 1-3 No Kids Nearby! Fig. 1-1 Avoid Dangerous Contact Fig. 1-2 No Tapping and No Extension Cords Fig. 1-4 Clean the Unit Samsung Electronics 1-1 MEMO 1-2 Samsung Electronics 2. Product Specifications 2-1 Table Model(Indoor/Outdoor) Item Power Source Capacity Energy efficiency ratio Air Flow Moisture removal Noise level Indoor(Hi/Mid/Low) Noise level Outdoor Capacity Energy efficiency ratio Air Flow Noise level Indoor(Hi/Mid/Low) Noise level Outdoor Available voltage range Running amperes Cooling Power input Power factor Running amperes Electrical Heating Power input Rating Power factor Starting current Fuse capacity Power cord Cable-connector Type Com- Model name pressor Oil/Quantity Safety devices Model name Indoor Running capacitor Fan motor Model name Outdoor Running capacitor Narrow tube : Liquid Refrigerant tube Wide tube : Gas Cooling Capillary tube Heating Refrigerant to charge (R22) Additional Refrigerant (R22) Indoor unit : W x H x D Dimension Outdoor unit : W x H x D Indoor unit Weight Outdoor unit Heating Remark : Test condition Cooling test Heating test ø-V-Hz W Btu/h Btu/wh m3/min \/h dBA W Btu/h Btu/wh m3/min dBA V A W % A W % A AxV AxV mm3 x G CC µF x VAC µF x VAC mmxMT mmxMT mm mm gr gr/m mm mm Kg Kg SH12VCD/SH12VCDX 1-220 / 240-50 3510(2340~4100) 12000(8000~14000) 9.0(11~7.7) 7.8 1.9 39 / 37 / 35 52 3800(2550~4980) 13000(8700~17000) 9.3(11.9~7.5) 8.3 39 / 37 / 35 53 187~264 5.9(3.2~8.2), MAX12A 1330(720~1820) 97.1(96.3~96.5) 6.1(3.3~10.0), MAX12 1400(730~2260) 99.8(96.2~98.3) 12 3.15 x 250 / 20 x 250 15 x 250 1.5 x 4

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : peavey xr684

script execution: 0.02 s