File information: | |
File name: | 814_Timer.pdf [preview 814] |
Size: | 171 kB |
Extension: | |
Mfg: | Crouzet |
Model: | 814 🔎 |
Original: | |
Descr: | Timer model 814 User Manual |
Group: | Electronics > Documentation |
Uploaded: | 06-01-2010 |
User: | renaud73 |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 814_Timer.pdf TIMER 814 GENERAL FUNCTIONS: A - Delay on Make B - Single Shot C - Delay on Make D Repeat Cycle ( OFF time first, equal ON/OFF time) Di - Repeat Cycle ( ON time first, equal ON/OFF time) H Interval TIME RANGES: 99.99 s 9999 s 99.99 min 9999 min 9999 hrs 999.9 s 99 min 59 s 999.9 min 99 h 59 min 999.9 hrs Note: The 99.99 s time range is not available in the Repeat Cycle Modes D and Di. - Simultaneous and constant display of the current value and pre-selection value (internal battery, minimum life span 10 years at 20°C) Up count (Up) or down count (Down) display Contact input 8 A / 250 VAC relay output (10 A UL) Power supply options: 24 VAC/DC, 110 VAC, or 220 VAC (tolerance + 10 % - 15 %) Front panel protection rating IP 64 - - 1/4 2 1 6 5 1: Power On Indicator 2: Initiate Switch Indicator 3: Timing Indicator 4: Timing Display (4 digits) 5: Timing Range Unit 6: Decimal Point 7: Mode of Operation 8: Up or Down Timing Mode 9: Timing Range 10: Relay Output Status 11: Program Mode 12: Validation 13: Preset Keyboard 14: Preset Value Display (4 digits) TIMER 814 4 10 14 9 12 13 11 8 5 7 READOUT LEGENDS MOUNTING REQUIREMENTS RUN MODE Configuration mode = Press one of the 4 keys 13 TIMER 814 T RANGE Time Display Sec., Min., Hr., Hr : Min, Hr : Min : Sec UP DOWN U d U = Up Count d = Down Count OUT MODE 2/4 T RANGE (Time Range) can be adjusted by pressing one of the 4 keys 13 corresponding to each digit. NOTE: a) During operation of the timer, change of time delay values: · taken into account immediately if your display is on the up count (Up) and if the new value is greater than the time that has already elapsed, · will be taken into account in the next cycle if you are on a down count display (down). b) The unit is supplied with the following configuration: 0.100 s, d (down), C (mode). c) If, inadvertently, you enter the unit test procedure with the entire screen or certain segments of the screen flashing, press the Mode pushbutton until Bp is obtained on the screen, then press Valid to return to normal operation. UTILIZATION PRECAUTIONS - The power cables and input circuits must be separate A minimum requirement for ventilation and protection from vibration must be proven. This equipment contains a lithium battery, do no incinerate the unit. MODES OF OPERATION A: Delay on Make PWR INI RST RLY OFF C: Delay on Break PWR INI RST RLY TON 3/4 MODES OF OPERATION B: Single Shot PWR INI RST RLY TON H: Interval PWR INI RST RLY TON D: Repeat Cycle, Off Time First - Equal PWR INI RST RLY TOFF TON TOFF TON t DI: Repeat Cycle, On Time First - Equal PWR INI RST RLY TON TOFF TON TOFF t DIMENSIONS AND ASSEMBLY 4/4 |
Date | User | Rating | Comment |