File information: | |
File name: | Pioneer-DJM400 mix.part1.rar [preview DJM400] |
Size: | 3072 kB |
Extension: | |
Mfg: | Pioneer |
Model: | DJM400 🔎 |
Original: | |
Descr: | DJ mixer |
Group: | Electronics > Consumer electronics > Audio |
Uploaded: | 30-01-2010 |
User: | AndyMn |
Multipart: | 0 1 2 |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name Pioneer-DJM400 mix.pdf 4 ORDER NO. RRV3351 DJM-400 DJ MIXER DJM-400 THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). Model DJM-400 DJM-400 DJM-400 Type KUCXJ RLXJ WYXJ5 AC 120V Power Requirement Remarks AC 110-120V / 220-240V AC 220-240V For details, refer to "Important Check Points for good servicing". PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Singapore 159936 PIONEER CORPORATION 2006 T-IZY MAR. 2006 printed in Japan 1 2 3 4 SAFETY INFORMATION A This service manual is intended for qualified service technicians ; it is not meant for the casual do-ityourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician. WARNING This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to cause cancer, birth defects or other reproductive harm. Health & Safety Code Section 25249.6 - Proposition 65 B NOTICE (FOR CANADIAN MODEL ONLY) Fuse symbols (fast operating fuse) and/or be of identical designation. (slow operating fuse) on PCB indicate that replacement parts must C REMARQUE (POUR MODÈLE CANADIEN SEULEMENT) Les symboles de fusible (fusible de type rapide) et/ou de remplacement doivent avoir la même désignation. (FOR USA MODEL ONLY) (fusible de type lent) sur CCI indiquent que les pièces 1. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER. LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120V AC 60 Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5 mA. 2. PRODUCT SAFETY NOTICE Many electrical and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components |
Date | User | Rating | Comment |