File information: | |
File name: | rs-9la-12la.pdf [preview RS12La] |
Size: | 1555 kB |
Extension: | |
Mfg: | Fuji |
Model: | RS12La 🔎 |
Original: | |
Descr: | Good 2 |
Group: | Electronics > Consumer electronics > Air conditioning |
Uploaded: | 10-06-2010 |
User: | silamp2 |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name rs-9la-12la.pdf S PLIT T Y PE R OOM A IR CON DIT ION E R WA L L M O U N T E D Models Indoor unit RS-9LA RS-12LA t y pe Outdoor unit RO-9LA RO-12LA CONTENTS SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . 1 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 3 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . 4 REFRIGERANT SYSTEM DIAGRAM . . . . 5 ERROR CONTENTS . . . . . . . . . . . . . . . . . . . 6 PCB CIRCUIT DIAGRAM . . . . . . . . . . . . . . 8 DISASSEMBLY ILLUSTRATION . . . . . . . . 10 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . 13 STANDARD ACCESSORIES . . . . . . . . . . . 15 S P E C I F I C A T I O N S T Y PE IN DOOR U N IT OU T DOOR U N IT COOLIN G CAPACIT Y ( ) : R ange HE AT IN G CAPACIT Y ( ) : R ange (kW ) (kW ) (COOL& HE AT IN VE R T E R ) R S -9LA R O-9LA 2.6(0.5~3.6) 3.6(0.5~6.0) (COOL& HE AT IN VE R T E R ) R S -12LA R O-12LA 3.5(0.9~4.2) 4.8(0.9~6.6) E LE CT R ICA L DATA POW E R S OU R CE FR E QU E N CY R U N N IN G CU R R E N T (A) (V) (Hz) COOLIN G HE AT IN G COOLIN G IN PU T WAT T S (kW ) HE AT IN G COOLIN G EER (kW /kW ) HE AT IN G (r /hr) (m 3/hr) 3.0 3.6 0.68(0.25~1.38) 0.91(0.25~1.96) 3.82 3.96 1.3 C 630 H665 230 50 4.6 5.8 1.03(0.25~1.61) 1.33(0.25~2.30) 3.40 3.61 1.8 C 630 H700 M OIS T U R E R E M OVAL AIR CIR CU LAT ION -Hi COM PR E S S OR T Y PE CODE R E FR IG E R AN T R 410A (g) 80206680 950 Hermetic type, 4 pole, 3 phase , DC brushles motor 80206680 1100 Note : Always use a vacuum pump to purge the air. Refrigerant for purging the air is not charged in the outdoor unit at the factory. FA N M OT OR POW E R S OU R CE HI-S PE E D (V) (r.p.m.) 230 C 1,350 H1,420 C 1,150 H1,200 C 950 H1,000 C 740 H900 830 230 C 1,400 H1,470 C 1,200, H1,290 C 1,000 H1,110 C 820 H980 1, 830 M E D-S PE E D (r.p.m.) IN DOOR U N IT LO-S PE E D QU IE T OU T DOOR U N IT (r.p.m.) (r.p.m.) (r.p.m.) 1, 1, DIM E N S ION S IN DOOR U N IT OU T DOOR U N IT HxWxD (mm) 280 x 790x 230 535 x 780 x 250 2003.06.09 1 W E IG HT S IN DOOR U N IT OU T DOOR U N IT G R OS S / N E T (kg) 35 / 33 12 / 9 37 / 34 N OIS E LE V E L HI-S PE E D M E D-S PE E D IN DOOR U N IT LO-S PE E D QU IE T (dB ) (dB ) C 31 H 30 C 23 H 26 C 47 H 49 C 32 H 33 C 26 H 29 C 47 H 49 (dB ) (dB ) C 42 H 42 C 37 H 36 C 43 H 43 C 39 H38 OU T DOOR U N IT (dB ) Note : Noise was measured in accordance with JIS standards, Japan. PIPE LE N G T H ADDIT ION AL R E FR IG E R AN T 7.5 m N one 10 m N one 15 m N one 2003.06.09 2 DIMENSIONS Models : RS-9LA / RO-9LA RS-12LA / RO-12LA 2003.06.09 3 C I R C U I T D I AG R A M Models : RS-9LA / RO-9LA RS-12LA / RO-12LA INDOOR UNIT OUTDOOR UNIT 2003.06.09 4 REFRIGERANT SYSTEM DIAGRAM Models : RS-9LA / RO-9LA RS-12LA / RO-12LA 2003.06.09 5 ERROR CONTENTS Self-diagnosis function table (Flashing LED Display) Applicable model : RS-9LA, RS-12LA * Detailed Trouble Display (secondary level) can be indicated by pressing Test Operation button. Trouble Display (primary) Detailed Trouble Display (by Test |
Date | User | Rating | Comment |