File information: | |
File name: | Fisher Paykel Washer Fault Codes.pdf [preview All] |
Size: | 852 kB |
Extension: | |
Mfg: | Fisher Paykel |
Model: | All 🔎 |
Original: | All 🔎 |
Descr: | Fisher Paykel Washer Machine Fault Codes |
Group: | Electronics > Consumer electronics > Washing Machines |
Uploaded: | 02-08-2010 |
User: | foxcopy |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name Fisher Paykel Washer Fault Codes.pdf ELECTRONIC WASHING MACHINE PHASE 6 Series 11 230v Supplementary to Issue A Oct 2000 517735 (including a complete new set of DETAILED FAULT CODES) Smart Drive 517765 517765 March 2004 19. DETAILED FAULT CODES DETAILED FAULT CODES FOR MODELS Phase 1 GW500 GW600 GW700 GW050 GW060 GW070 GW650 Phase 2 GW701 GW601 GW501 MW051 W015 MW061 MW071 Phase 3 GW703 GW603 GW503 MW053 LW035 Phase 4 GW708 GW608 W508 MW058 LW085 AW085 GWC08 GWM08 GWL08 THM08 THL08 Phase 5 GW709 GW609 GW509 MW059 LW095 AW095 GWC09 GWM09 GWL09 Phase 5 IW IW709 IW609 IW509 IWL10 IWM10 IWC09 IW710 IW810 IWM09 IWL09 Phase 6 GW711 GW611 GW511 MW511 GWL11 GWM11 GWC11 Phase 6 IW IW811 IW711 IW511 IWL11 IWM11 MWC11 INTRODUCTION The format for fault description in this booklet follows the Primary, Secondary, Tertiary and Quaternary fault source system. These sources have mostly been arranged in order of most likely source of fault, but in some cases the sequence has been modified to aid the servicing procedure. It should be noted that the fault source Pump System includes the pump and drain hose assembly. Fault code shows the last recorded fault. Always confirm fault. - 25 - 517765 March 2004 FAULT DESCRIPTIONS 1. (00000001) Phase 1 - Display Module Fault Phase 2 to 6 - Motor Controller Module Fault The Motor Controller Module (Display for phase 1) has encountered an error when writing to an Eeprom address. Primary Source: Motor Controller module. (Display Module for Phase 1) Action: Replace Motor Controller module. (Display Module for Phase 1) (00000010) Phase 1 - Display Module Fault Phase 2 to 4 - Motor Controller Module Fault An error has been encountered when trying to read the pressure sensor. Primary Source: Motor Controller module. (Display Module for Phase 1) Action: Replace Motor Controller module. (Display Module for Phase 1) (00000011) Phase 1 to 6 Motor Controller Module Fault The Motor Controller Module has found a memory error. Primary Source: Motor Controller module. Action: Replace Motor Controller module. (00000100) Phase 1 - Communications Fault The Motor Controller has had difficulty communicating with the Display Module Primary Source: Motor Controller module. Action: 1. Turn off at the wall and on again after 5 seconds and try again. 2. If still faulty, replace the Motor Controller 3. Replace Display Module. If the new Display Module corrects the fault, then refit the original Motor Controller. (00000101) Phase 1 - Communications Fault The Display Module has had difficulty communicating with the Motor Controller. Primary Source: Display Module. Action: Turn off at the wall and on again after 5 seconds and try again. 1. Check connections of the 12 way harness for bad contacts, corrosion etc. 2. Check for moisture in the console area. Dry out if necessary 2. If still faulty, replace the Display Module 3. If still faulty, replace the Motor Controller. If the new Motor Controller corrects the fault, then refit the original Motor Controller. (00000110) Phase 1 |
Date | User | Rating | Comment |