File information:
File name:fluke 27fm.rar
[preview 27FM]
Size:913 kB
Extension:rar
Mfg:Fluke
Model:27FM 🔎
Original:
Descr:Fluke27FM (true rms)service manual/schematic
Group:Electronics > Automobile > Electrical diagram
Uploaded:04-06-2012
User:dtmf75
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:4
File name FLUKE 27______smeng0100.pdf

® Multimeter 27 Service Manual For IEC 61010 CAT III Meters Only PN 690206 November 1998 Rev.1, 9/03 © 1998,2003 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. Table of Contents Chapter 1 Title Page Introduction and Specifications ... 1-1 1-1. 1-2. 1-3. Using the Meter Safely ... 1-3 Operating Instructions ... 1-4 Specifications... 1-5 2 Theory of Operation ... 2-1 2-1. 2-2. 2-3. 2-4. 2-5. 2-6. 2-7. 2-8. 2-9. 2-10. Introduction... Functional Description ... Block Diagram Description ... Input Overload Protection ... Function Switching Circuits... Signal Conditioning Circuits ... Custom Analog IC (U1) ... Peripherals to U1 ... Microcomputer Control... Display... 2-3 2-3 2-3 2-4 2-4 2-4 2-4 2-6 2-6 2-7 3 Maintenance... 3-1 3-1. 3-2. 3-3. 3-4. 3-5. 3-6. 3-7. 3-8. 3-9. 3-10. 3-11. 3-12. 3-13. 3-14. 3-15. 3-16. Introduction... Service Information ... Operator Maintenance ... Battery Replacement ... Fuse Test... Fuse Replacement... General Maintenance Information... Handling Precautions for Static-Sensitive Devices... Disassembly... Reassembly... Cleaning...
File name FLUKE 27______umeng0200.pdf

® Multimeter Users Manual Mode d'Emploi Bedienungs-Handbuch Manuale d'Uso Manual de Uso 27 For IEC 61010 CAT III Meters Only October 1998 Rev.2, 12/03 © 1998-2003 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke 20, 70, 80, 170 and 180 Series DMM will be free from defects in material and workmanship for its lifetime. As used herein, "lifetime" is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least ten years from the date of purchase. This warranty does not cover fuses, disposable batteries, damage from neglect, misuse, contamination, alteration, accident or abnormal conditions of operation or handling, including failures caused by use outside of the product's specifications, or normal wear and tear of mechanical components. This warranty covers the original purchaser only and is not transferable. For ten years from the date of purchase, this warranty also covers the LCD. Thereafter, for the lifetime of the DMM, Fluke will replace the LCD for a fee based on then current component acquisition costs. To establish original ownership and prove date of purchase, please complete and return the registration card accompanying the product, or register your product on http://www.fluke.com. Fluke will, at its option, repair at no charge, replace or refund the purchase price of a defective product purchased through a Fluke authorized sales outlet and at the applicable international price. Fluke reserves the right to charge for importation costs of repair/replacement parts if the product purchased in one country is sent for repair elsewhere. If the product is defective, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Fluke will pay return transportation for product repaired or replaced in-warranty. Before making any non-warranty repair, Fluke will estimate cost and obtain authorization, then invoice you for repair and return transportation. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO EXTEND ANY DIFFERENT WARRANTY ON FLUKE'S BEHALF. Since some states do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. If any provision of this warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validi
File name FLUKE 27______umeng0201.pdf

Manual Supplement Manual Title: Part Number: Print Date: Revision/Date: 27 Users 690203 October 1998 Rev.2, 12/03 Supplement Issue: Issue Date: Page Count: 1 3/05 1 This supplement contains information necessary to ensure the accuracy of the above manual. © 1999-2005 Fluke Corporation. All rights reserved. Printed in the U.S.A. x 27 Users Manual Supplement Change #1 On page 2, add the following Warning at the end of the page. WWarning To prevent hazard, do not use or apply voltage in wet locations and be sure to dry this product properly prior to use. The fluke model 27 case is water tight enclose effective to 2PSI (a water depth of 5 feet). If the product has been submerged or is wet by indications of surface moisture, remove the moisture by allowing the product to properly dry before use. Moisture or water located within the terminals, seams or product surface may result in a hazard for applied voltages. On page 3, under Table 1, add the following: P Complies with European Union directives 3/05 1
File name FLUKE 80PK-27_iseng0000.pdf

® 80PK-27 SureGrip Industrial Surface Temperature Probe TM Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically connected to the output terminals. XW Attention Pour éviter les risques d'électrocution, ne pas utiliser cette sonde quand la tension est sepérieure à 24 V efficaces en courant alternatif ou 60 V en courant continu. La pointe de la sonde est reliée électriquement aux bornes de sorties. XW Warnung Um Elektroschock zu vermeiden, dürfen Sie den Meßstift nicht in der Anwesenheit von Spannungen über 24V Wechselstrom oder 60V Gleichstrom verwenden. Die Spitze des Meßstifts ist mit den Ausgangsanschlüssen elektrisch verbunden. XW Advertencia Para evitar descargas eléctricas, no use esta sonda cuando se apliquen voltajes que sobrepasen 24 V ca rcm o 60 V cc. La punta de la sonda está conectada eléctricamente a las terminales de salida. Introduction The 80PK-27 SureGripTM Industrial Surface Temperature Probe is designed for reliably measuring temperatures to 600 °C (1112 °F) on flat or slightly convex surfaces, while retaining a long service life. Specifications Type: K (Chromel vs Alumel) Measurement Range: -127 °C to 600 °C (-196.6 °F to 1112 °F) Junction Accuracy: -127 °C to 0 °C ±4.4 °C (-196.6 °F to 32 °F ± 7.92 °F) 0 °C to 183 °C ±2.2 °C (32 °F to 361 °F ±4.86 °F) 183 °C to 600 °C ±1.2 % of reading in °C (361 °F to 1112 °F ± <1.2 % of reading in °F) Output: 25 °C (77 °F) = 1.00 mV (Reference junction at 0 °C) Seebeck Coefficient: 25 °C (77 °F) = 40.50 µV/°C November 2004 © 2004 Fluke Corporation. All Rights Reserved. All product names are trademarks of their respective companies Measurement Time (Time Constant): 1 time constant equals 330 ms; 5 time constants equal final reading. See "Application Information" below. Maximum Voltage Rating at Probe Tip: 24 V ac rms, or 60 V dc Probe Tip: Maximum Temperature: 600 °C (1112 °F) Material: 303 stainless steel Sheath Material: 303 stainless steel Cable Length: 40 inches (1 meter) Cable Isulation: Material: PVC Maximum Temperature: 105 °C (220 °F) Minimum Temperature: -20 °F Conductors: Type: K Size: AWG #24 stranded (7 strands of #32) Length: 1.2 meters nominal (4 ft) Handle: Material: Hytrel Maximum Temperature: 65.6 °C (150 °F) Minimum Temperature: -40 °C (-40 °F) Connector: Type: yellow mini-thermocouple connector with 0.792 mm (0.312 in) pin spacing Material: Hytrel Maximum Temperature: 125 °C (275 °F) Dimensions: Diameter: 22.9 mm (0.9 in) Length: 322.6 mm (12.75 in) Measurement Considerations Instrument Compatibility The 80PK-27 is designed to be compatible with any temperature measuring instrument that accepts Type K thermocouples, has a miniature thermocouple connector, and has cold reference junction compensation. Accuracy of the temperature measuring instrument must be considered along with the 80PK-27 accuracy specifications in order to determine the overall



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.