File information: | |
File name: | SyncMaster 753DF.zip [preview 753DF] |
Size: | 1062 kB |
Extension: | |
Mfg: | Samsung |
Model: | 753DF 🔎 |
Original: | 753DF 🔎 |
Descr: | SyncMaster 753DF |
Group: | Electronics > Computer equipment > Monitors |
Uploaded: | 09-03-2004 |
User: | plamensl |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name SyncMaster 753DF.pdf COLOR MONITOR SyncMaster 753DF (DF17K*) SyncMaster 755DF (DF17J*) SERVICE COLOR MONITOR Manual CONTENTS 1. Precautions 2. Product Specifications 3. Disassembly & Reassembly 4. Alignment & Adjustments 5. Troubleshooting 6. Exploded View & Parts List 7. Electrical Parts List 8. Block Diagram 9. Wiring Diagram 10. Schematic Diagrams Samsung Electronics Co., Ltd. May 2000 Printed in Korea P/N : BH68-00129G-01 1 Precautions 1-1 Safety Precautions WARNINGS 1. For continued safety, do not attempt to modify the circuit board. 2. 3. Disconnect the AC power before servicing. When the chassis is operating, semiconductor heatsinks are potential shock hazards. 3. 2. Inspect all protective devices such as nonmetallic control knobs, insulating materials, cabinet backs, adjustment and compartment covers or shields, isolation resistor-capacitor networks, mechanical insulators, etc. Leakage Current Hot Check (Figure 1-1): WARNING: Do not use an isolation transformer during this test. Use a leakage current tester or a metering system that complies with American National Standards Institute (ANSI C101.1, Leakage Current for Appliances), and Underwriters Laboratories (UL Publication UL1410, 59.7). With the unit completely reassembled, plug the AC line cord directly into a 120V AC outlet. With the unit's AC switch first in the ON position and then OFF, measure the current between a known earth ground (metal water pipe, conduit, etc.) and all exposed metal parts, including: metal cabinets, screwheads and control shafts. The current measured should not exceed 0.5 milliamp. Reverse the power-plug prongs in the AC outlet and repeat the test. (READING SHOULD NOT BE ABOVE 0.5mA) 1-1-1 Servicing the High Voltage VR and CRT : WARNING:A high voltage VR replaced in the wrong direction may cause excessive X-ray emissions. Caution: When replacing the high voltage adjustment VR, it must be fixed by a soldering iron after it is properly set. 1. When servicing the high voltage system, remove the static charge by connecting a 10 kohm resistor in series with an insulated wire (such as a test probe) between the chassis and the anode lead. If the HV VR requires adjustment, (a) Replace the VR and adjust the high voltage to the specification. (b) Use a soldering iron to melt the adjustment cap on the HV VR to prevent any movement. When troubleshooting a monitor with excessively HV, avoid being unnecessarily close to the monitor. Do not operate the monitor for longer than is necessary to locate the cause of excessive voltage. High voltage should always be kept at the rated value, no higher. Only when high voltage is excessive are X-rays capable of penetrating the shell of the CRT, including the lead in glass material. Operation at high voltages may also cause failure of the CRT or high voltage circuitry. When the HV regulator is operating properly, there is no possibility of an X-ray problem. Make sure the HV does not exceed its specified value and that it is regulating correctly. T |
Date | User | Rating | Comment |
20-03-2011 | adem08 | 1 | sehema |