File information: | |
File name: | Troubleshooting.pdf [preview Troubleshooting] |
Size: | 4840 kB |
Extension: | |
Mfg: | Samsung |
Model: | Troubleshooting 🔎 |
Original: | Troubleshooting 🔎 |
Descr: | Samsung Refridgerators RF263AEPN Service Manual Troubleshooting.pdf |
Group: | Electronics > Other |
Uploaded: | 16-01-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name Troubleshooting.pdf 4. TROUBLESHOOTING 4-1. Function for failure diagnosis 41 4-1-1) TEST FUNCTION 41 4-1-2) COMMUNICATION ERROR DISPLAY FUNCTION 43 4-1-3) SELF DIAGNOSIS FUNCTION 43 4-1-4) LOAD STATUS DISPLAY FUNCTION 46 4-1-5) EXHIBITION MODE 48 4-1-6) OPTION SETTING FUNCTION 48 4-1-7) Option TABLE 51 4-2. Trouble-Shooting (Flow Chart) 53 4-2-1) WHEN SELF-DIAGNOSIS ERROR OCCURS 54 4-2-2) WHEN THE FAN DOES NOW OPERATE (F, R, C - FAN) 63 4-2-3) WHEN ICE MAKER (R) DOES NOT OPERATE 64 4-2-4) WHEN DEFROST DOES NOT WORK (F, R DEF HEATER) 65 4-2-5) WHEN POWER IS NOT APPLIED 66 4-2-6) WHEN COMPRESSOR DOES NOT RUN (INVERTER COMP) 67 4-2-7) WHEN THE UNIT KEEPS ALARMING (BUZZER SOUND) 69 4-2-8) WHEN THE PANEL PCB DOES NOT OPERATE NORMALLY 71 4-2-9) WHEN THE PANTRY PANEL PCB DOES NOT OPERATE NORMALLY 72 4-2-10) WHEN THE ROOM LAMP DOES NOT LIGHT UP 73 4-2-11) WHEN WATER DOES NOT SUPPLY AT ICE MAKER 75 4-2-12) WHEN WATER IS NOT SUPPLIED (RF266 OPTION) 76 4-2-13) WHEN THERE IS NO POWER AT INVERTER PCB 77 4-2-14) TROUBLESHOOTING BASED ON LED BLINKING FREQUENCY 78 40 TROUBLESHOOTING 4-1) Check-List before Trouble-Shooting 4-1-1. Test Function (Forced Operation / Forced Defrost Function) When pressing the Power Freeze and Fridge buttons for 8 seconds at the same time, it will shift to the Test Mode and the entire Display Panel will go off. Each time when any one of the buttons on the Display Panel is pressed within 15 seconds after shifting to the Test Mode, its operation will be shifted in the order of Forced Operation 1 (FF 1) Forced Operation 2 (FF 2) Forced Operation 3 (FF 3) Forced F/R Defrost (Fd) Cancellation (Display all off). When there is no button pressed within 15 seconds after being shifted to the Test Mode, the Test Mode will be cancelled and it will shift to the normal display mode. To cancel the Test Mode while it is performing the Test Mode, it is recommended to plug out and plug in the unit. 1) Forced Operation Press the Power Freeze and Fridge buttons for 8 seconds at the same, The entire Display will be off, and when pressing any one of the buttons, it will shift to the Test Mo |
Date | User | Rating | Comment |