Accrediting Artifact Calibration of a Multi-Function Calibrator David Bartley Staff Engineer Fluke Corporation Everett, Washington, USA Presented at the Measurement Science Conference February 5, 1998 Abstract A decade ago, two companies introduced electronic instruments incorporating Artifact Calibration, a technology by which an instrument calibrates itself using a small number of external standards, thereby significantly reducing the cost of calibration and simplifying their path of traceability. Some national standards laboratories have been cautious about accepting Artifact Calibration, perhaps because most of the external verification traditionally done is replaced by characterizations performed inside the instrument beyond the control and oversight of the operator. However, the large reduction in cost of ownership that comes with Artifact Calibration is a strong motivation for broader acceptance, particularly for high accuracy instruments whose calibration would otherwise require time-consuming procedures and more expensive standards. Toward this end, the national standards laboratories of the Netherlands (Nederlands Meetinstituut or NMi), Sweden (Sveriges Provnings-och Forskninginstitut or SP), and Germany (Physikalisch- Technische Bundesanstalt or PTB) undertook an independent evaluation of Artifact Calibration as implemented in the Fluke 5700A with the goal of increasing acceptance of Artifact Calibration. This paper gives background for the project and briefly reports preliminary project results and conclusions. A more complete report will be published later in 1998, and among others will be presented at the October 1998 meeting of the DC/LF experts group of the European co-operation for Accreditation (EA). Acknowledgments I am in the enviable position of writing the first paper reporting on this project after having done little of the work, so I find it particularly essential to give my heartfelt thanks to: Gert Rietveld, Cock Oosterman, Cees van Mullem, and Joop Dessens of NMi; H

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Fluke 5725a gseng0003 - Fluke at25010an10sq27 - Fluke Fluke 5700A serial capture - Fluke DN2540 - Fluke testlog 5700a - Fluke 74HC HCT4052 - Fluke Initial F5700A Cal Dump -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Loewe Opta Stereo Chssis 4743W

script execution: 0.03 s