File information:
File name:aurand_sandia_scd5000_deconv.pdf
[preview aurand sandia scd5000 deconv]
Size:109 kB
Extension:pdf
Mfg:Tektronix
Model:aurand sandia scd5000 deconv 🔎
Original:aurand sandia scd5000 deconv 🔎
Descr: Tektronix aurand_sandia_scd5000_deconv.pdf
Group:Electronics > Other
Uploaded:05-03-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name aurand_sandia_scd5000_deconv.pdf

WEP-4 BANDWIDTH ENHANCEMENT OF SINGLE-SHOT DATA ACQUISITION SYSTEMS BY DECONVOLUTION OF SYSTEM RESPONSE John F. Aurand, Paul1 E. Patterson, Charles A. Frost Sandia National Laboratories / High-Power ElectromagneticsDepartment MS 1153, PO Box 5800 / Albuquerque, NM 87185-1153 Abstract SCD-5000 to a host personal computer, and then deconvolution processing. The FlT spectrum of the Procedures have been developed [ 11 for enhancing the acquired signal is divided by the system transfer effective bandwidth of single-shot measurement function, and then an inverse FFT is used to compute systems. One procedure characterizes the transfer the compensated timedomain input signal. If function of the measurement system hardware, and necessary, any one of several lowpass filtering the other is a software compensation technique to algorithms may then used to reduce the deconvolution deconvolve this transfer function from the acquired data. The example shown employs a Tektronix SCD-5000 Transient Digitizer, with a -3 dB bandwidth improvement of 4.5 times, to over 15 GHz. System Characterization noise. 2-10 h 3 -20 0 0 ..._ ... ~ ... _.__.__._,.._._.__...,~...~... ... ^... . ...~... Each of the components of a single-shot data .t acquisition system (coaxial cabling, delay line, and waveform recorder) is band-limited, and thus degrades the acquired waveform. The measurement -50 system hardware is modeled as a cascaded frequencydomain transfer function, and if mismatch 0 5 10 I5 20 S parameters are assumed negligible, then the transfer Frequency (GHz) function

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Tektronix readme - Tektronix TEK 11A72 User - Tektronix TEK 7B53A 252C 7B53AN Instruction - Tektronix TEK 7A29 Instruction - Tektronix TEK 7B85 Operations Manual - Tektronix TEK 11A52 User Reference - Tektronix TEK 7B71 Instruction -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Philips philips plhc-a961a chassis ram1.0ala pwr sch

script execution: 0.03 s