datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Fluke 5720A mveng0000

Fluke 5720A mveng0000 free download

Various electronics service manuals

File information:
File name:5720A___mveng0000.pdf
[preview 5720A mveng0000]
Size:21 kB
Extension:pdf
Mfg:Fluke
Model:5720A mveng0000 🔎
Original:5720A mveng0000 🔎
Descr: Fluke 5700a 5720A___mveng0000.pdf
Group:Electronics > Other
Uploaded:20-03-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 5720A___mveng0000.pdf

Instrument Security Procedures Models: Fluke 5720A Product Name: Multi-Function Calibrator Instrument Description: 5720A is a five-function calibrator designed to address the most demanding electrical calibration workload. Memory Description: The Fluke 5720A Multi-Function Calibrator contains two types of storage media. The first is a flash-based storage media and the second is random access memory (RAM). Flash Memory: The flash memory used in the 5720A is a physically block structured device. It contains three (3) separate blocks. The first block is a special purpose block intended to hold a small boot loader. It's used for that purpose within the 5720A. The boot loader software was designed and maintained by the Fluke Corporation and is preprogrammed into the flash device for us by the vendor. The boot loader flash memory can't be easily changed or reconfigured without special programming equipment. It's considered by Fluke to be permanent. If it were tampered with, or otherwise changed, by anyone other than qualified software engineer equipped with supporting documentation from Fluke, and external programming hardware, the calibrator would cease to function. The second block contains the application software for the 5720A. It's programmed by Fluke but is otherwise subject to the same stringent restrictions as the boot code. Additionally, a checksum is generated and compared on power-up to insure that no changes to this code have occurred. The third block is logically partitioned, by the software, into two (2) mini-blocks. The first contains the calibration constants for the instrument. The second contains all nonvolatile configuration data for the instrument. Calibration Constants: Calibration constants are double precision floating-point numbers. These numbers are used by the instrument during normal operations to achieve its rated output accuracy. Each calibration constant (CCO) has a default value and a limit. Most limits are within a few percent of the default value. It's impossible to set a calibration constant to a number outside of its limit. Calibration constants can't be accessed directly by a user. They can be changed during a calibration 5720A SOMV 1 of 3 11/29/2006 process. Theoretically, someone could run a calibration procedure and store numerically encoded data in the calibration constants. The limits on many of them would obviously complicate the process though. Non-Volatile Configuration Data: Non-Volatile configuration data contains user settings like IEEE address, serial port configuration, calibration dates, etc. It also contains a string of a maximum of 63 characters. The string is

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Fluke 5720a ogita0100 - Fluke Readme - Fluke Fluke 5700A serial capture - Fluke 5725a gseng0003 - Fluke DN2540 - Fluke testlog 5700a - Fluke 74HC HCT4052 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Trio CS-1577A CS-1577H

script execution: 0.02 s