datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Philips FMxx Ticking noise rework instructions

Philips FMxx Ticking noise rework instructions free download

Various electronics service manuals

File information:
File name:FMxx_Ticking_noise_rework_instructions.pdf
[preview FMxx Ticking noise rework instructions]
Size:216 kB
Extension:pdf
Mfg:Philips
Model:FMxx Ticking noise rework instructions 🔎
Original:FMxx Ticking noise rework instructions 🔎
Descr: Philips Symptom Cure 17-04-2004 References FMxx_Ticking_noise_rework_instructions.pdf
Group:Electronics > Other
Uploaded:02-04-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name FMxx_Ticking_noise_rework_instructions.pdf

1. FM24 "Ticking noise" rework instructions 1.1. SYMPTOM: Loud cabinet ticking noises during warming up / cooling down. 1.2. CURE: Create a small space between the glass plate and the cabinet, filled with a flexible material, in this case sticky tape (e.g. Scotch "Magic Tape 810"). 1. Place the set face down on a soft surface. 2. Lift and remove the metal rear cover plate. 3. Lift and remove the plastic rear cover. 4. Disconnect the cable at the LED/Switch panel. 5. Remove the "ESM Filter" panel at the left bottom (if present). 6. Remove all fixation screws of the (metallised) shielding frame (do NOT remove the PDP from the frame). 7. Lift and remove the frame together with the PDP and PWBs attached to it, and store it at on a soft surface. Now, do the following: 8. First, lift and remove the Glass Plate from the Front Assy, and store it in a safe place. 9. Now, apply tape all around the inner side of the Front Assy, exactly covering the small raised edge (see figure 1). Work accurate, so that the tape is not visible for the customer! 10. Next, take the Glass Plate and apply tape all around the edge at both sides (see figure 2). This creates a hard (glass) - soft (tape) - hard (cabinet) construction. 11. Re-assemble the set. Figure 1 Front assy Tape Raised edge Figure 2 Front assy Tape Glass plate (copper shielding)

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Philips FC8438 - Philips dvdr520h 209 - Philips FC9116 - Philips fc9302[1] - Philips FC842102 - Philips FC8400 - Philips FC9003 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Technics RS-TR575

script execution: 0.02 s