1. LC4.6E: Audible plop when switching "off" the set.

1.1. Rework Instructions

On the SSB:




3


1 470R
2k2
B
2




E_14780_142.eps
130704
1) Remove SMD resistor 3702.
2) Mount a (leaded) resistor of 2k2 between the base of 7714 and pin 5 of 7709.
3) Mount a (leaded) resistor of 470R between the base of 7714 and pin 3 of 7709.




4




E_14780_143.eps
120704
4) Mount a wire between pin 3 of 5735 and 4720 (at connector 1702 side).