Text preview for : Philips_HQ-7885_Aquagenic_Quadra_Shaver_2011_SM.pdf part of Philips Philips HQ-7885 Aquagenic Quadra Shaver 2011 SM Philips Household HQ-7885 Philips_HQ-7885_Aquagenic_Quadra_Shaver_2011_SM.pdf



Back to : Philips_HQ-7885_Aquagenic | Home

Shaver
HQ 7885

AQUAGENIC
QUADRA



Philips Domestic Appliances and Personal Care




Service Manual SAP coding HQ 7885

HINTS FOR REPAIR: TECHNICAL DATA:
- Remove the shaving unit, to prevent damages during Voltage : 100 - 240 Volt 50 - 60 Hz
repairing. Motor voltage : 2,4 Volt
- Remove screws A1 (2x) Open trimmer for screw. Shaving heads : HQ6 - 4822 690 10214
- Take cover from housing (trimmer must be closed).
- Remove brackets (14 and 21).
- The PCB-board can now be removed out of the housing.
- Remove the connecting strip from the motor by
dis soldering.
- Remove screws B1 (2x) now the motor and hairchamber
can be removed out of the housing.
- Detach the motor springs (17) from the gearwheel unit with
a small screwdriver.

ASSEMBLY:
- Think by assembly on right placing of the trimmer

GENERAL:
- Recharcheble shaver
- Constant motor voltage
- Electronic push on/off
- Washable
- NiCd cell 2AA
This product meets the requirements regard-
- Charge time 1hr/30min
- Charging (mains) indication LCD ing interference suppression on radio and TV.
- Battery low indication LCD
- Battery full indication LCD
- Minutes left LCD
After the product has been repaired, it should
function properly and has to meet the safety
requirements as officially laid down at this
moment.




Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands