Text preview for : pa98-04.pdf part of Philips pa98-04 Philips Symptom Cure 2001-02 SymptomCure references pa98-04.pdf
Back to : pa98-04.pdf | Home
For internal use only PHILIPS
ISSUE PA98.04 (98-07-24)
Published by:
Service Department LOBPA Hong Kong
LINE OF BUSINESS PORTABLE AUDIO
SERVICE NEWSLETTER
04.01 TYPENUMBER(S): AJ3925
INFORMATION : Following parts are changed from production start onwards to
improve distortion and amplification reserve:
Capacitor 2210 and 2213 are changed to 4.7nF (4822 126 11714)
Resistor 3201 and 3204 are changed to 6.8k (4822 116 83961)
3202 and 3205 are changed to 27k (4822 116 52264)
3221 and 3222 are changed to 18k (4822 116 52251)
REMARKS : Changes are applied to sets of new generation with production code
"KT-02" only.
04.02 TYPENUMBER(S): AJ3940
INFORMATION : Correction to the Instruction Fof Use:
To set WEEKEND SLEEPER, only following steps are necesary:
1. Select the alarm you wish to deactivate by pressing the
ALM 1 or 2 button. Within 5 seconds the display shows the
set alarm time. Briefly press the WEEKEND SLEEPER once.
If the weekend sleeper is activated, zz will appear in the display
for ALARM 1 or 2.
2. To cancel the weekend sleeper function, repeat step 1 until zz
no longer appears in the display.
REMARKS : Errata sheet will be inserted from week 9831 onwards.
The IFU will also be updated.
Service Newsletter 1998