Text preview for : SNL2000-06.pdf part of Philips SNL2000-06 Philips Symptom Cure 2001-02 SymptomCure references SNL2000-06.pdf



Back to : SNL2000-06.pdf | Home

For internal use only PHILIPS

ISSUE SNL2000.06 (00-07-06)
Published by:
Service Department Audio

BUSINESS CREATION UNIT AUDIO

SERVICE NEWSLETTER
06.01 TYPENUMBER(S): AQ5460

SYMPTOM : IRIS CODE 1 5 4 2
Hiss is audible on recordings.

CURE : Phenomenon is caused by unstability of the bias oscillator.
Change resistor 3732 from 10 to 15 (4822 116 52182).

REMARKS : Modification has been implemented in production from week 0014
onwards.


06.02 TYPENUMBER(S): AZ1030, AZ1035

INFORMATION : To solve the problem ,,skips tracks due to acoustic feedback" the CD-
clamper assembly (items 428, 429 and 431) has been replaced by
the new clamper assembly (3140 117 59800) .

REMARKS : New CD-clamper assemblies are used in production from week 0024
onwards.


06.03 TYPENUMBER(S): AZ1040, AZ1045, AZ1120

INFORMATION : To solve the problem ,,skips tracks due to acoustic feedback" the CD-
clamper assembly (items 436, 437 and 438) has been replaced by
the new clamper assembly (3140 117 59800) .

REMARKS : New CD-clamper assemblies are used in production from week 0024
onwards.


06.04 TYPENUMBER(S): AZ1040, AZ1045, AZ1550, AZ1560, AZ1565

SYMPTOM : IRIS CODE 1 5 4 2
Hiss is audible on recordings.

CURE : Phenomenon is caused by unstability of the bias oscillator.
Change resistor 3732 from 10 to 15 (4822 116 52182).

REMARKS : Modification has been implemented in production from week 0014
onwards.


Service Newsletter 2000