Adjustment Method
White Balance Adjustment
Instrument Name Connect to Remarks
1. Remote controller Correlation can be also taken by
2. LCD WB meter (Minolta CA-210 or equivalent) CS-1000A or equivalent
3. Comunication jig
4. Computer for external control
Procedure Remarks
Let the panel standfor more than 3
hours at more than 20 C.
White Balance adjustment Basically perform adjustment in the
1. Procedure basically performs checking using the production software and ambient environment of room
make automatic adjustment using external computer. temperature more than 20 C.
2. It adjusts in the mode of: Colour balance Normal The aging time is more than 20 min
Viewing Mode Dynamic at above room temperature.
Applied signal
Normal 100% full colour bar
Highlight x: 0.288 0.010 0.7V p-p white peak
y: 0.297 0.010 85% modulation
Normal
Lowlight x: 0.288 0.010 100% WHITE
y: 0.297 0.010
50% GRAY