Battery Shaver "Marco Polo"
HQ 302/A
Service
Service
Service
Domestic Appliances and Personal Care
SAP Coding HQ 302
HINTS FOR REPAIRS
DISASSEMBLY SK1
- Remove the shaving unit, to prevent damages
during repairs.
- Remove the batterieholder.
+
- Unlock the snaplocks from the tailpart. A
3X1.5V M
- Lift the motor unit out of the housing. LR6
- Loosen the motor clamp springs on the bearing.
block of the motor with a small screwdriver.
- Unlock the peg-clamping 'Z' (2X) between frame
(item 8) and hair chamber (item 5).
- To remove the trimmer, first disassemble the trimmer
slide by pushing down the locking pegs 'V' (2X) and
move slide slightly outwards.
- Maken room between trimmer and cover with a small TECHNICAL DATA
screwdriver, to release the peg fastening 'Y'.
Operating voltage : 4.5V
Power supply : 3X AA/LR6 battery
ASSEMBLY Shaving heads : 2X HQ3
Comfort control : fixed setting
- The assembly must be carried out in the reverse Trimmer : pop-up system
order of what is discribed under Disassembly.
- When fitting the shaver it must be checked if
wiring is correctly positioned.
PRODUCTS MEETS THE REQUIREMENTS REGARDING
INTERFERENCE SUPPRESION ON RADIO AND TELEVISION.
- AFTER THE PRODUCT HAS BEEN REPAIRED IT SHOULD
FUNCTION PROPERLY AND HAS TO MEET THE SAFETY
REQUIREMENTS AS LAID DOWN OFFICIALLY ESTABLISHED
AT THIS MOMENT.