Text preview for : SNL1999.pdf part of Philips SNL1999 Philips Symptom Cure 2001-02 SymptomCure references SNL1999.pdf



Back to : SNL1999.pdf | Home

For internal use only PHILIPS

ISSUE PA99.05 (99-12-03)
Published by:
Service Department Portable Audio

LINE OF BUSINESS PORTABLE AUDIO

SERVICE NEWSLETTER
05.01 TYPENUMBER(S) : AE6775, AE6780

SYMPTOM : IRIS CODE D 1 1 3
No battery contact for some battery types only.

CURE : The ribs for fixing the battery contact wire are too close together for
batteries with large plus-pole diameter. For such battery types the
plus-pole of the upper battery will not contact the wire properly.
Service solution: Cut the inner ribs with a knife

REMARKS : Modified Cabinets are used in production from week 9947 onwards.


05.02 TYPENUMBER(S): AZ1005

INFORMATION : Correction to the Service Manual, Partslist
The codenumber for the CD Door Switch is missing.
The switch is available with codenumber 4822 278 90739.

REMARKS :


05.03 TYPENUMBER(S) : AZ1009, AZ1010, AZ1015

SYMPTOM : IRIS CODE 3 1 6 1
The Bracket-Cassette (item 502 for AZ1009, AZ1010 resp. item 501
for AZ1015) is broken at the support area for the Cassette Door
Spring (item 404).

CURE : Tooling has been modified (increased wall thickness and added
radius at the corner).
Improved Bracket-Cassettes are available with codenumber
3103 304 64080.

REMARKS : Modified parts are used in production from week 9945 onwards.




Service Newsletter 1999