A.Preparation to upgrade software:
1. Unzip the zip-archive attached to this Service Newsletter
2. Start the CD Burning software and create a new CD project (data Disc) with the following settings:
File system: ISO9660
Format: MODE 1: CDROM
Recording mode: SINGLE SESSION (TRACK-AT-ONCE), FINALIZED CD
3. Place the content of the zip-archive (1 file) into the root directory of the new CD project.
4. Burn the data onto a blank CDR

Note: ISO9660 is mandatory, UDF discs are not supported !
The final CDROM must not contain any other data except the file from the zip-archive.


B.Procedure to apply the software upgrade:
1. Power up the set and open tray.
2. Insert the prepared Upgrade CDROM and close the tray.
3. The set will start reading and display the following messages:
* LOAD [After the disc is read. the tray will open for you to remove the disc]
* ERASE 0 -> ERASE F ..... -> ERASE 0
* WRITE F ..... -> WRITE 0
* UPG END [only for a short moment, if unsuccessful ERROR is display]
* DISC
* LOAD [Tray will close indicating that the upgrade process is completed]
4. Disconnect the set from mains supply.
5. The whole process should last for about 5 minutes.
Note: Do not press any buttons or interrupt the mains supply during the upgrading process,
otherwise the set may become defective.


C.Reprogramming the DVD version Matrix
1. Put the set in Stop mode with tray open
2. Press buttons <9> <9> <9> <9>