Text preview for : sm_C55_lvl2l.pdf part of siemens c55 service manual



Back to : sm_C55_lvl2l.rar | Home

Local Service Organization Service Manual
BE INSPIRED

C55 / 2128

WHICH SIDE ARE YOU ON?

Our Innovation Shapes the Future

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

TABLE OF CONTENTS
1 2 3 4 5 6 6.1 7 7.1 7.2 7.3 7.4 8 9 10 11 GPRS (GENERAL PACKET RADIO SERVICE).............................................. 1 K-JAVA APPLICATION ...................................................................................... 2 KEY FEATURES.................................................................................................... 3 OTHER FEATURES.............................................................................................. 4 COMPARISON WITH PREVIOUS PRODUCTS.............................................. 5 ACCESSORIES ...................................................................................................... 6 ACCESSORIES PART NUMBER....................................................................7 UNIT DESCRIPTION L55 TUNA........................................................................ 8 ASSEMBLY CONCEPT FOR THE CUSTOMER .................................................8 C55 / 2128 MECHANICAL DIAGRAM ...........................................................9 PCB TOP-SIDE .......................................................................................10 PCB BOTTOM-SIDE .................................................................................10 DISASSEMBLY OF C55/2128 ............................................................................ 11 REASSEMBLY OF C55/2128 ............................................................................. 13 SPARE PARTS & PART NUMBERS ................................................................ 14 MOBILE SOFTWARE PROGRAMMING....................................................... 15 MOBILE SOFTWARE UPDATING.......................................................16 FLOW CHART FOR S/W UPGRADING .........................................................17

11.1 11.2 12

SIEMENS SERVICE EQUIPMENT USER MANUAL ................................... 18

12.1 INTRODUCTION .......................................................................................18 12.2 SIEMENS MOBILE SERVICE EQUIPMENT ....................................................18 12.2.1 R&S CMD55 Test Station .................................................................19 12.2.2 R&S CTS55 Test Station ..................................................................19 12.2.3 Wavetek 4201S Test Station.............................................................20 12.3 OTHER EQUIPMENT ................................................................................20 12.4 SOFTWARE INSTALLATION .......................................................................21 12.4.1 Configuring the test software ............................................................22 12.4.2 Running the test sequence ...............................................................23

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

Contents Page 1

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

1 GPRS (GENERAL PACKET RADIO SERVICE)

G

PRS is a new non-voice value added services that allows information to be sent and received across a GSM mobile telephone network. It supplements today's Circuit Switched Data (CSD) and Short Message Services (SMS). GPRS involves overlaying a packet based air interface on the existing circuit switched GSM network. This gives the option to use a packet-based data service. The information is split into separated but related "packets" before being transmitted and reassembled at the receiving end. Theoretically, maximum speeds of up to 171.2 kilobits per second (kbps) are achievable with GPRS using all eight timeslots at the same time. This is about 3 times as fast as the data transmission speed possible over today's fixed telecommunications networks and 10 times as fast as current Circuit Switched Data services on GSM networks.

Figure1. Example of GPRS data transmission Example: Cell with 1 Frequency channel: 1 physical channel for signalling, 4 physical channels for Circuit switched and 3 physical channels for Packet switched

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

1 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

2 K-JAVA APPLICATION
Java-based game system Java Application Manager (JAM) RAM for Java applications
Application launcher and download manager. Supports HTTP-based OTA download of applications over GPRS and CSD. Available RAM for Java applications (ie. program code and data) during application runtime: Minimum: 100 Kbyte (Has to be taken as working assumption for application development.) Goal: 145 Kbyte as SL45i (not committed)

yes

yes

MIDP 1.0, CLDC 1.0 'OEM extensions' HTTP API over GPRS

As SL45i, including performance optimizations from SL45i-Infusio. Proprietary API extensions as SL45i. Including 'Siemens Game API' SL45i: only over CSD

yes yes yes

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

2 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

3 KEY FEATURES
General: · Hands free · Flash file system · New sound concept with polyphonic ringing tones / social noises · Kjava (identical to K45-Manta) · LiIon Battery Pack 700 mAh · Power Input: 1.8 A (0.6 ms) / 0.2 A (4 ms) · Cut-off Threshold 3.2 V · approx. 250 h measured at BSPAMFRMS = 9; number of neighbouring cells = 0 · Best case approx. 5 hours (lowest output level with DTX) · Worst case approx. 2.5 hours (highest output level without DTX) · Conditions for DTX: 40% user talk time · Small (="Plug In") 1.8 V or 3 V-SIM card (Phase II). · To insert the SIM the battery pack must be removed. · The SIM reader coding will be realized by lower case. · Full Rate, Enhanced Full Rate, Adaptive Multi Rate and Half Rate speech coders are available as standard. · Type: Full Graphic · Resolution: 101 X 64 Pixel · Illumination: Amber · 12-digit block (0-9, #, *), small letters · two function keys (SEND, END) · ON/OFF key combined with the END key; the symbol (I inside O) is used as a symbol for ON/OFF. · 4 way navigation key as centered rocker type (up&down / 2 softkeys on left & right position) · amber as illumination colour · orientation at the housing in the area between keys "5" and "8" · comfortable earpiece with optimal acoustics · unidirectional microphone (similar to SL45 with modified rubber gasket) · loud signal emitter (soundringer) (>100dB(A) SPL @5cm, 'Hongkong-Spec.') · different call melodies (for the amount see SW product description). Realized with DSP firmware sound solution. All melodies with increasing volume because of the danger of acoustic shock. Additional measures to protect from acoustic shock, see SW product description.

Battery:

Stand-by Time: Talk Time:

SIM Card:

Speech Coder: Display:

Keypad:

Acoustics:

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

3 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual · handsfree mode · different selectable volume levels for handsfree, handset and ringer mode (for the amount see SW product description)

4 OTHER FEATURES
· · · · · · · · · · · · · · · · · · · Games (Java Based) Voice command/dialing Integrated handsfree Calling Images: Download a photo of your friend and link it to his phone book entry Greetings (Reminder of important dates) Get in touch (Conference Call) & SMS to group Text modules (SMS) Diary (appointments, notes) Flexible Memory PIN protected screensaver & notes Various animations (menu, welcome) Silent Alert Various user profiles Intelligent Typing (T9) + Libraries Mobile Internet Access (WAP 1.2.1) Built in data & fax modem @ 9.6 kbps Moon phase screensaver (2128 only) VOIP Predial Integrated sound concept (polyphonic melodies with up to 16 voices) for: - MMI - Ringer melodies - Recordable sounds

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

4 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

5 COMPARISON WITH PREVIOUS PRODUCTS
Feature Supported Systems Stand-by Time Talk Time Battery Technology Battery Capacity Weight Volume Length Width Thickness SIM Antenna Antenna Performance in comparison to S35: Half Rate Enhanced Full Rate AMR Fax/Data GPRS Keypad Illumination Display / Display Illumination Ringer volume level K45 Flipper Dual Band E-GSM 900 / GSM 1800 Up to 200 h Up to 5 h Ni-MH Battery Pack Nominal Cap. : 550 mAh Approx. 106 g Approx. 82 cm3 L55 Tuna Dual Band E-GSM 900 / GSM 1800 Up to 250 h Up to 5 h Li-Ion Battery Pack Nominal Cap.: 750 mAh Approx. 84 g Approx. 69 cm3 Improvement Same +20% stand-by time Same Li-Ion first time as standard in Csegment -20% weight reduction -16% volume reduction 8 mm shortening 1.0 mm ... 2.0 mm width reduction 1.1 mm ... 2.2 mm thickness reduction

108,9 mm (Panther) 100,9 mm 42.0 ... 46.0 mm (Panth) 19.0 ... 23.0 mm (Panth) Plug-In 1.8V/3V Integrated -0,5 dB @ 900 MHz -0,3 dB @ 1800 MHz Yes Yes No Yes No Yes (amber) FSTN full dot matrix, 5 lines graphic Min. 100 dB(A) @ 5cm Typ. >103 dB(A) @ 5cm 41.0 ... 44.0 mm 17.9 ... 20.8 mm

Plug-In 1.8V/3V Same Integrated Same -0,8 dB @ 900 MHz -0,5 dB @ 1800 MHz Yes Yes Tbc Yes Yes Yes (amber) Same Same New in C-segment Same New in C-segment Same

Same FSTN full dot matrix, 5 lines graphic Min. 100 dB(A) @ Same 5cm Typ. >103 dB(A) @ 5cm
Siemenes Techincal Support Center

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

5 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

6 ACCESSORIES
Due to changes on the connector from "Lumberg" to "Slim Lumberg", accessories using the old "Lumberg" connector will not be able to be used on the new "Slim Lumberg" platform.

C55 Original Accessories EMEA Portfolio

Basics Basics
Carry Set Carry Set FCS-500 FCS-500 CLIPit CLIPit Covers Covers Carrying Carrying Cases Cases Li-Ion Li-Ion Battery Battery EBA-510 EBA-510 Headset Headset PTT PTT HHS-510 HHS-510 Desk Top Desk Top Charger Charger EDC-510 EDC-510 Travel Travel Charger Charger ETC-500 ETC-500 ETC-510 ETC-510 Car Charger Car Charger ECC-500 ECC-500

Car Solutions Car Solutions
Car Kit Car Kit Prof. Voice Prof. Voice HKV-500 HKV-500 Car Kit Car Kit Comfort Comfort HKC-500 HKC-500 Car Kit Car Kit Portable Portable HKP-500 HKP-500 Basic Basic Car Pack Car Pack HKB-500 HKB-500 Mobile Mobile Holder Holder HMH-500 HMH-500 Mobile Mobile Holder Holder Antenna Antenna HMH-510 HMH-510 Car Kit Car Kit Upgrade Upgrade HKO-500 HKO-500 Car Kit Car Kit Upgrade Upgrade HKO510 HKO510 Car Car Handset Handset HKO-550 HKO-550

Innov. Innov.

Data Data
Data Cable Data Cable DCA-500 DCA-500 Data Cable Data Cable USB USB DCA-510 DCA-510

(Desk Top Stand, Y-Adapter, (Desk Top Stand, Y-Adapter, Data Cable) Data Cable)

SyncStation SyncStation DSC-500 DSC-500

compatible to L55 and future products C55 and S55 only C55 only

ICM MP CCQ SF

www.my-siemens.com/customercare

Page 1

© Siemens, 2002

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

6 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

6.1 Accessories Part Number
Accessories L36104-F3090-X903 Handsfree Loudspeaker S45/ME45/C45/M45/C55/S55 L36146-A2053-D Con.Cable Battery Install. Comfort GPS/rat C35/C35 L36254-Z6-C95 Handsfree Microphone aktiv S45/ME45/C45/M45/C55/S5 L36880-N4501-A135 HKO-520 Push-To-Talk-Key L36880-S4501-A300 E-Box Carkit Voice S45/ME45/C45/M45/C55/S55 german L36880-S4501-A301 E-Box Carkit Voice S45/ME45/C45/M45/C55/S55 englis L36880-S4501-A302 E-Box Carkit Voice S45/ME45/C45/M45/C55/S55 french

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

7 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

7 UNIT DESCRIPTION L55 TUNA
The L55 Tuna is designed as a single-pcb phone with exchangeable covers and exchangeable keypad. The upper- and lower-cover are designed as two-coloured parts, which is realized in 2-shot-moulding technology.

7.1 Assembly Concept for the Customer

Chassis

exchangeable Rear-Cover exchangeable Front-Cover battery

SIM-Card

exchangeable keypad

The C55 is the first Siemens Mobile phone that enables the customer to freely customize the outlook of their phone via the means of exchangeable Front/Rear covers as well as keypad.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

8 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

7.2 C55 / 2128 Mechanical Diagram

D isp la y-W in d o w

U p p e r-C a se K e yp a d

S A R -F ra m e S A R -A b so rb e r (o p tion a l) LCD L ig h tg u id e

E S D -F ra m e S p e a ke r-G a ske t

S p e a ke r

M e ta ld o m e -F oil

PCB V ib ra -m o to r A n te n na M icro p h o n e

M o u n tin g -F ra m e

B a tte ry

L o w e r-C a se

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

9 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

7.3 PCB top-side

7.4 PCB bottom-side

The C55/2128 assembly concept differs from the previous models (P35 & K45 series) slightly. The C55/2128 is no longer employing the concept of "No Screws". Instead of the previous upper & lower mounting frame to hold the PCB and the housing together, the C55/2128 uses six screws to hold the light guide, PCB and the mounting frame together. As seen from the mechanical diagram, the C55/2128 also uses two other different techniques from the previous models (P35 & K45 series). (1) The use of a light guide on the front panel to disperse the light evenly throughout the keypad & display area. (2) The use of a metal dome foil as keypad contact as opposed to the carbon/metallic contact keypads used in the P35 & K45 series.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

10 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

8 DISASSEMBLY OF C55/2128
Step 1 Step 2

Front view of the C55/2128

Back view of the C55/2128

Step 3

Step 4

Remove the battery cover by pushing it upwards as indicated by the arrow.

The C55/2128 comes with a hinge on the top part of the phone for customers to hang their accessories.

Step 5
With the battery cover removed, proceed to remove the battery by releasing the catch on the side.

Step 6

With the battery removed, you would then be able to see the SIM card, which is held down by a metallic catch.

Step 7

Step 8

Once the catch has been removed, the SIM card would pop up from the holder automatically.

Proceed to remove the front cover by pushing it up lightly.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

11 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual Step 9 Step 10

Once the front cover has been removed, proceed to remove the 6 screws on the front with a "T6" screw driver; as indicated by the red circles.

Once the screws has been removed, you would be able to see the internal single PCB.

Step 11

Step 12

Once the screws has been removed, the PCB can also be seperated from the back casingof the phone. The antenna is built-in on the back case.

As it can be seen from the photo, the keypad can also be separated from the front casing.

Step 13

Fully disassembled C55

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

12 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

9 REASSEMBLY OF C55/2128
For the reassembly of the C55/2128, simply reverse the disassembly procedures from Step 13 to Step 1. However there are some things to note on the reassembly of the phone. During the installation of the SIM card, ensure that the SIM card is properly locked in. If not, it would result in card error, as the SIM card will not be properly held in place.

Ensure that the SIM card is fully inserted and that the metallic lock is pulled down. During the installation of the battery, ensure that the hinges are properly in place. Otherwise the battery will not be able to fit into the phone properly.

Ensure that the hinges are properly fitted before fixing in the battery.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

13 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

10 SPARE PARTS & PART NUMBERS
Level 1 L36158-A102-B600 Keypad C55/C56 Level 2.5 L36197-F5005-F782 L36334-Z93-C272 L36334-Z97-C160 L36840-L2055-D670 L36840-L2056-D670 Display LED blue MT50/M50/M46/C55 Antenna Connector C35/C35i/S35i/M35i/SL45/ S45/ME4 Battery Connector S45/ME45/C55/S55 Display LED Amber S35i/S45/ME45/C45/M50/C55/C56 Keyboard LED Amber S35i/S45/ME45/C45/S46/M50/MT50/

Level 2.5E L36120-F4223-H Resistor Temp_Resistor L36145-F102-Y8 Quartz EGold/Logic (B1 lay.) L36145-G100-Y96 Z850 Filter 1LO_VCO L36145-K260-Y41 Z851 Filter Filter_BALUN L36820-C6047-D670 Diode / Transistor Tran._Switch L36820-L6105-D670 D800 Digital Integrated Circuit (IC) Transceiver I L36830-C1097-D670 Diode / Transistor L36840-C4049-D670 Diode / Transistor Tran._VCXO_Ampl. L36840-D5049-D670 Diode / Transistor Feedback_Diode L36840-D61-D670 Diode / Transistor Capa_Diode L36851-Z2002-A59 Z900 Filter Power_Amplifier L36851-Z9105-Z981 Diode / Transistor

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

14 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

11 MOBILE SOFTWARE PROGRAMMING
The common mobile software available is divided into language groups. However, this software does not contain the specific settings, such as ringing tones, greeting text, short dial list etc., required by the operator(s) or service provider(s). Therefore, it is not uncommon to have some menu item(s) differ in different variants or are not visible at all. These settings are stored in different memory area of the mobile and will be activated depending on the customer specific model or variant of the phone by a separate test step during the production process. Due to this separation of common mobile software and customer specific initialization, it is possible to fulfill the demands of the market requiring customization and flexibility. As a consequence the software programming process in the LSO is divided into two different steps as followed: - Software update to actual version and appropriate language group - Programming of CUSTOMER SPECIFIC INITIALIZATION

FIGURE 2.24 C55 SERIES SOFTWARE PROGRAMMING SETUP

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

15 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

11.1 MOBILE SOFTWARE UPDATING
The software of the mobile, L55 series, is loaded from a PC directly. Hardware interconnection between the mobile and the PC is shown in Figure 2.24 Because of the new type of external connector used in X55 series (Slim-Lumberg type) an additional adaptor cable between mobile and boot adaptor is required. Table 2.1 listed all the hardware requirements If you use the battery dummy, make sure that the power supply voltage is correctly adjusted. Description Part No.

Bootadapter 2000 incl. AC-Adapter, serial cable and mobile connection cable
IBM Compatible PC ­ Pentium

L36880-N9241-A200
-

TABLE 2.1 EQUIPMENT LIST FOR SOFTWARE PROGRAMMING.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

16 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

11.2 Flow chart for S/W upgrading
Plug in the Boot Adaptor to the PC and Mobile Start the SWUP program S/W upgrading in progress

Connec t the AC adaptor to the Boot Adaptor

Select & Execute the "Mobile S/W"

ERROR? NO

YES

P o we r u p B o ot Adaptor & check LED.

ERROR? YES

NO

TEST Mobile

OK? NO

YES

Check H/W setup = S/W

Take note of error and repeat process

Check AC Adaptor

OK?

Feedback Error to Tech. Supp. Dep

YES

OK? NO

Correct Settings

END

Faulty AC Adaptor

Faulty Boot Adaptor

FLOW CHART FOR S/W PROGRAMMING PROCESS
Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC Siemenes Techincal Support Center

17 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

12 SIEMENS SERVICE EQUIPMENT USER MANUAL
12.1 Introduction
Every LSO repairing Siemens handset must ensure that the quality standards are observed. Siemens has developed an automatic testing system that will perform all necessary measurements. This testing system is known as:

12.2 Siemens Mobile Service Equipment
Using this system vastly simplifies the repair of the phones and will make sure that: 1. All possible faults are detected 2. Sets, which pass the test, will be good enough to return to customer. Starting from the P35 Series, Siemens will introduce a simpler and faster testing platform for testing a repaired Siemens mobile phone. The testing platforms are either base on R&S CMD 53/55 or CTS55 GSM test set. There is also test software under development for testing with the Wavetek 4201S and the 4107 GSM test set. A Level 2.5 service software is also under development for more elaborate testing for the repair for the P35 series mobile phone.

THE LSO WILL HAVE TO PURCHASE THE SYSTEM, CHOOSING BETWEEN THE COMPLETE PACKAGE OR SUB-SET OF IT. A FULLY AUTOMATIC TEST PROCEDURE IS ONLY POSSIBLE IF THE COMPLETE SYSTEM IS INSTALLED.

Make sure that your CTS firmware is Version 3.01 or higher. For CMD 55 it must be Version 4.03 and higher. Please check with the Service Info SB_0500 for the CTS/CMD Hardware Options.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

18 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

12.2.1

R&S CMD55 Test Station

12.2.2

R&S CTS55 Test Station

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

19 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

12.2.3

Wavetek 4201S Test Station

12.3 Other Equipment
One Pentium MMX Window 95/98 PC with a serial port to connect to the GSM test set through the PC serial cable provided for the GSM test set. One Test SIM card and a fully charged battery for used with the mobile phone model. Additional RF connector will be needed for setup using Wavetek 4107 test set and Wavetek Antenna Coupler. For LSO Test Station setup base on the Wavetek 4107 test set, you need a TNC (male) to SMA(female) connector. For the Wavetek Antenna Coupler, you need a TNC (female) to SMA(female) connector. The part number for the connectors will be announced soon.

For Wavetek GSM test set
Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

For Wavetek Antenna Coupler
Siemenes Techincal Support Center

20 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

12.4 Software Installation
Before executing the test software, it is important to ensure that the software configuration matches that of the hardware set up. Each GSM Tester will have specific test software. The test software is named CMD_GO, CTS_GO and for Wavetek test set, CAT4200 respectively. First, copy the installation software for the specific GSM tester to a temporary directory on the harddisk of the Window PC and then Run the Setup from the first sub directory ­ Disk1 for CMD_GO test software. After the installation for the test software, RUN the Test software and check the configuration setting for the Serial port.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

21 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

12.4.1

Configuring the test software

For each model of the L55 series mobile phone, Siemens will distribute the testing configuration file for the specific test station. For testing the phone, just go to the File menu and select Load Configuration.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

22 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual

Make sure that your CTS firmware is Version 3.01 or higher. For CMD 55 it must be Version 4.03 and higher. Please check with the Service Info SB_0500 for the CTS/CMD Hardware Options.

12.4.2

Running the test sequence

Insert a Test SIM card and a fully charged battery into the Siemens mobile phone and place it onto the phone holder on the Antenna Coupler. Switch the RF switch to INT ANT position and select the Start button to run the test sequence in the configuration file.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

23 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual Follow the instruction on the screen and switch on the phone. The mobile phone will start Network Search and doing Location Update to the GSM test set through the off-air signal from Antenna Coupler.

Next, the GSM test set will initial a call to the mobile phone through the Antenna Coupler. Press the Call key when the mobile phone ring, and the GSM test set will start Tx Power measurements on the GSM and GSM1800 channel specified by the configuration setting.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

24 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual Next, the GSM test set will end the call to the mobile phone and the screen will prompt for Dialing from the mobile phone. At this test step, please move the mobile phone to the Antenna Cradle and switch the RF switch to EXT ANT position. Once the mobile phone logs onto the GSM test set, dial 1234 and the Send key.

The GSM test set will make Tx Power measurements, Rx BER measurement, Echo Loop test on the GSM and GSM1800 channel specified by the configuration setting. There will be an Echo Loop Back test for checking the speech quality. Speak into the mobile phone when prompted and listen the voice after approx 1 second and check the speech quality. If not O.K, it may be microphone or the earphone defective.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

25 of 28

Internal Service Use Only

SIEMENS Pte Ltd
C55/2128 Level 2 Service Manual The last test is Disconnect Call from the mobile phone. Press the End Call key and the test sequence will end.

A measurement report screen will show up and a hardcopy can be printed if a printer is connected to the PC. To close the measurement report screen, click the third button from the left.

Once the mobile phone pass all the test steps, please make a check for all keys and the display. After this we can confirm on the proper functioning of the mobile phone after repair and return the phone back to the customer.

Copyright © Siemens Pte. Ltd. All rights reserved ICM MP CCQ ASP/ASC

Siemenes Techincal Support Center

26 of 28

Internal Service Use Only