For internal use only PHILIPS
ISSUE PA98.07 (98-12-16)
Published by:
Service Department Portable Audio
LINE OF BUSINESS PORTABLE AUDIO
SERVICE NEWSLETTER
07.01 TYPENUMBER(S): AZ1020
INFORMATION : In course of production, following modifications have been
implemented:
1. Prevent residual images on LCD in tape mode
Resistor 3863 changed to 470 (4822 116 83883)
2. Improved muting function in tuner search mode
Resistor 3400 changed to 4.7k (4822 116 52283)
3. Improved sound quality
Capacitors 2301 and 2302 changed to 22nF (4822 121 70619)
Resistors 3303 and 3304 changed to 820 (4822 116 52231)
REMARKS :
07.02 TYPENUMBER(S): AZ1200, AZ1202
INFORMATION : In order to reduce the distortion of CD-recordings, following
modification has been implemented in production:
1. Resistors 3529 and 3530 changed to 22k (4822 116 52257)
2. Resistors 3578 and 3579 changed to 22k (4822 116 52257)
REMARKS :
07.03 TYPENUMBER(S): AZ2000
INFORMATION : Correction to the mechanical partslist (Exploded View diagram):
The service codenumber of item 444 should read:
4822 442 01499 Cabinet-Top (not for /17)
4822 442 01689 Cabinet-Top (for /17 only)
REMARKS :