For internal use only PHILIPS

ISSUE SNL2000.07 (00-09-11)
Published by:
Service Department Audio

BUSINESS CREATION UNIT AUDIO

SERVICE NEWSLETTER
07.01 TYPENUMBER(S): AJ3935, AJ3936

SYMPTOM : IRIS CODE 2 6 1 9
The Compact Disc gets sticked onto the CD-Clamper assembly.

CURE : Replace the old Clamper assembly (items 434, 436 and 437) by the
new one 3140 117 59800.

REMARKS : New CD-Clamper assemblies are used in production from week 0025
onwards.


07.02 TYPENUMBER(S): AS800C, AS801C, FW-C28, FW-C38, FW-C39, FW-C40, FW-C55,
FW-C58, FW-C71, FW-C72, FW-P75, FW-P78, FW-C80, FW-C83,
FW-C85, FW-M55, FW-V28, FW-V55, FW545C/34, FW548C/21K/34,
FW590C/34, FW595C/21K, FW830C/22/34, FW840C/22, FW850C,
FW855C, FW860P, FW870C/22, FW878C/34, FW880P, FW880W,
FW890P/22, FW898W/34, MZ7

INFORMATION : Service Manual, Partslist
The Cam Gear (pos 25) of the Tape mechanism has been added as
service spare part. The codenumber reads 9965 000 06443.

REMARKS :


07.03 TYPENUMBER(S): AZ1030

INFORMATION : Due to supply shortfall of servo IC TDA7073A, the CD part of the
Combi board assembly had to be redesigned for LA6530. The new
Combi board assemblies are used in production alternatively.

For repair information on new Combi board assembly see Service
Information A00-558 (3140 785 22460).

REMARKS : Alternative Combi board assemblies are used in production from
week 0028 onwards.