Text preview for : 1svcnote.pdf part of panasonic 1svcnote panasonic LCD PT-50LC13 PT-50LC13 SVC 1svcnote.pdf



Back to : 1svcnote.pdf | Home

LED INDICATIONS FOR ERROR CONDITION
Each LED indication facilitates finding the cause of the error.
When an error is detected, each LED on the front will light up or flash when the AC Cord is plugged in.
The detected error data will not be stored in the EEPROM. This data is cleared when the AC Cord is unplugged.



POWER LED


TEMP LED LAMP LED

(Note 3) (Note 4)
Error No. Error Information ERROR DESCRIPTION POWER LED TEMP LED LAMP LED OSD LAMP OFF
1) Fan1, Fan2 or Fan3 IC6302(pin6) detects the stop of FAN1, FAN2 or FAN3, flashes orange
stopped then indicates the error when the FAN1, FAN2 or FAN3 is once every - -
stopped. 5 seconds
2) Lamp Cover open IC6003(pin66) detects the Lamp Cover condition flashes orange
(open or close), then indicates the error when the Lamp Cover twice every - -
is open. 5 seconds
3) Temperature Sensor IC6302(pin4 and 5) detects open or short of the Temperature flashes once
shorted or open Sensor (R2811) on Thermistor 1 C.B.A., then indicates the - every 5 seconds -
error when Temperature Sensor is open or shorted.
(The error is not detected for 1 minute after Lamp ON.)
4) Abnormal IC6302(pin4 and 5) detects the temperature near flashes twice
Temperature the FAN1 by the Temperature Sensor (R2811) on Thermistor 1 - every 5 seconds -
C.B.A., then indicates the error when the temperature exceeds
55 C (131 F).
(The error is not detected for 1 minute after Lamp ON.)
5) Ballast Error IC6003(pin19) detects the error of the Lamp, and Ballast C.B.A., flashes green for flashes once
(abnormal Lamp) then indicates the error when an inner malfunction of Ballast 140 seconds. every 5 seconds
-
C.B.A. occurs, the Lamp voltage becomes more than 130V or flashes red
less than 30V, the Lamp is cracked, the Thermal Fuse Unit is
open or the Lamp is not cooled off.
6) Ballast Error IC6003(pin19) detects the error of the Lamp, then indicates the flashes green for flashes twice
(abnormal error when the Lamp is defective. 140 seconds. every 5 seconds
-
Lamp voltage) flashes red
7) Ballast Error IC6003(pin19) detects the error of Ballast C.B.A., flashes green for flashes 3 times
(abnormal then indicates the error when the thermal fuse (F1302) 140 seconds. - every 5 seconds
temperature) 117 C (243 F) in Ballast C.B.A. is open. flashes red
8) Ballast Error IC6003(pin19) detects the error of Ballast C.B.A., flashes green for flashes 4 times
(other causes) then indicates the error when an inner malfunction of Ballast 140 seconds. - every 5 seconds
C.B.A. occurs. flashes red
9) Abnormal Voltage IC6302(pin61) detects +33V line voltage on Main C.B.A., then flashes orange flashes once flashes once
on 33 V line of indicates the error when the voltage becomes less than +10V. 5 times every every 5 seconds every 5 seconds
Main C.B.A. 5 seconds
10) Abnormal Voltage IC6302(pin64) detects +9V line voltage on Main C.B.A., then flashes orange flashes twice flashes twice
on 9 V line of indicates the error when the voltage becomes less than +2V. 6 times every every 5 seconds every 5 seconds
Main C.B.A. 5 seconds
11) Abnormal Voltage IC6302(pin63) detects +5V line voltage on Main C.B.A., then flashes orange flashes 3 times flashes 3 times
on 5 V line of indicates the error when the voltage becomes less than +1V. 7 times every every 5 seconds every 5 seconds
Main C.B.A. 5 seconds
12) Abnormal Voltage IC6302(pin7) detects +3.3V line voltage on Main C.B.A., then flashes orange flashes 4 times flashes 4 times
on 3.3 V line of indicates the error when the voltage becomes less than +1.5V. 8 times every every 5 seconds every 5 seconds
Main C.B.A. 5 seconds
13) Abnormal Voltage IC6302(pin62) detects -5V line voltage on Main C.B.A., then flashes orange flashes 5 times flashes 5 times
on -5 V line of indicates the error when the voltage becomes more than 0V. 9 times every every 5 seconds every 5 seconds
Main C.B.A. 5 seconds
14) Abnormal Voltage IC6302(pin60) detects +6.5V line voltage on Main C.B.A., then flashes orange flashes 6 times flashes 6 times
on 6.5 V line of indicates the error when the voltage becomes less than +2V. 10 times every every 5 seconds every 5 seconds
Main C.B.A. 5 seconds
15) Temperature Sensor IC6302(pin2 and 3) detects open or short of the flashes 3 times
shorted or open Temperature Sensor (R2821) on Thermistor 2 C.B.A., - every 5 seconds -
then indicates the error when Temperature Sensor is open or
shorted.
(The error is not detected for 4 minutes after Lamp ON.)
16) Abnormal IC6302(pin2 and 3) detects the temperature near flashes 4 times
Temperature the Lamp by the Temperature Sensor (R2821) on Thermistor 2 every 5 seconds
C.B.A., then indicates the error when the temperature exceeds - -
85 C (185 F).
(The error is not detected for 4 minutes after Lamp ON.)
17) Clogged air filter IC6003(pin65) detects clogged air filter when the filter detection
flashes 5 times
value exceeds the standard value. - every 5 seconds -

18) Request for Lamp When accumulated Lamp operation time reaches 10,000
Replacement hours, OSD (replacing the Lamp) appears on the screen. - - lights up
Note: The Lamp time is stored in EEPROM (IC6005).
- Forced cooling Indicated during forced cooling. flashes red for flashes 5 times
10 minutes - every 5 seconds

Note:
1. When any of the above errors has occurred, the LED will flash as shown above.
2. When two or more errors have occurred at the same time, the LED will alternate light up and/or flash patterns as shown
above every 5 seconds.
3. Warning OSD appears when the air filter is clogged or accumulated Lamp operation time reaches 10,000 hours.
4. LAMP OFF: The LED will flash immediately after the Lamp comes off.
5.IC6003 and IC6302 are mounted on the Main C.B.A.
MAIN PARTS LOCATION






Network C.B.A.




TEMP LED
LAMP LED
Lamp Cover
Cover Switch C.B.A.
Network C.B.A.
Optical Cover

POWER LED
Front Cover Unit Operation C.B.A.







20-pin Cable




Projection Unit

Thermal Fuse Unit Thermistor 2 C.B.A.
Fan 3
Thermistor 1 C.B.A.
Air Filter
Fan Case Unit
(Fan 1)



Fan 2
Air Filter
Front Jack C.B.A. Ballast C.B.A. Air Filter LCD Drive C.B.A.

Main C.B.A.
Tuner C.B.A.


Audio Fan 4
Amp C.B.A.
Rear Cover


Power C.B.A. Rear Jack C.B.A.
TV/Tuner Unit
SERVICE MODE
Service Mode Map
In this mode, the following information can be confirmed on the
screen: Enter :
VOLUME DOWN button + TV/VIDEO key
Service Mode (1/3) (on the front) (on the remote)