Text preview for : SNL2000-05.PDF part of Philips SNL2000-05 Philips Symptom Cure 2001-02 SymptomCure references SNL2000-05.PDF



Back to : SNL2000-05.PDF | Home

For internal use only PHILIPS

ISSUE SNL2000.05 (00-06-09)
Published by:
Service Department Audio

BUSINESS CREATION UNIT AUDIO

SERVICE NEWSLETTER
05.01 TYPENUMBER(S): AJ3935

SYMPTOM : IRIS CODE 2 1 4 4
Transformer hum is audible.

CURE : The hum is caused by vibration of the metal transformer bracket (item
502). For service purpose the metal bracket can be removed without
substitution.

REMARKS : In production, a rubber foam of 20 x 25 x 26 mm will be placed
between top of transformer and Top Cabinet (item 427).
This will protect the printed board from being damaged during transit.

The modification has been implemented in production from week
0014 onwards.


05.02 TYPENUMBER(S): AZ1005, AZ1007

INFORMATION : Due to supply shortfall of servo IC TDA7073A, the CD module had to
be redesigned for IC TCA0372DP1. The new modules are used in
production alternatively.

For repair information on new CD modules see Service Information
A00-551 (3140 785 22310).

REMARKS : Alternative CD modules are used in production from week 0013
onwards.


05.03 TYPENUMBER(S): AZ1100, AZ1101, AZ1102, AZ1103, AZ1104

INFORMATION : Due to supply shortfall of servo IC TDA7073A, the CD module had to
be redesigned for IC TCA0372DP1. The new modules are used in
production alternatively.

For repair information on new CD modules see Service Information
A00-552 (3140 785 22320).

REMARKS : Alternative CD modules are used in production from week 0013
onwards.



Service Newsletter 2000