Text preview for : power.pdf part of panasonic power panasonic Video NV-HS960EG Viewing SGML_VIEW_DATA EU NV-HS860EG-K SVC power.pdf



Back to : power.pdf | Home

CAUTION THE STRIPED FRAME INDICATES THE PRIMARY CIRCUIT TO DISTINGUISH THE PRIMARY
IP1230 C1232
FROM THE SECONDARY CIRCUIT. 100P
0
PAY ATTENTION NOT TO RECEIVE AN ELECTRIC SHOCK DURING REPAIR AND SERVICE OF D1230 L1230
100u
ERA22-04
THE PRODUCTS. 1 2
T1150
F ETE28K121AZ C1230 C1231 P1102
50V82 0.01
HOT 1 GND
10 C1242 2 GND
100P 3 GND
4 GND
D1240 L1240 5 GND
AK04V2 22u 6 UNREG -29V
C1123 LB1121
1000P 0 8 11 7 UNREG 4V
8 HEATER(+)
P1101 D1140 C1240 C1241 9 UNREG 6V
VJS3306 S1WBA80 10V1200 10V1000
LB1122 C1252 L1250 10 HEATER(-)
L1120 L1121 0 22u 11 UNREG 36V
ELF15N005A ELF17N004A + P2 100P
4 1 7 12 12 GND
D1250 13 GND
C1250 C1251
3 4 1 2 D1302 RL2ZPLF-C4 25V1000 25V1000
14 GND(MOTOR)
RD100E 15 UNREG 16V
C1151
16
C1140 0.01 P1
C1120 R1120 C1121 6 13
AC INLET 400V R1155
E 0.1 330K 0.1
68 27K IP1270 C1272
100P
TO SYSTEM CONTROL & SERVO
SECTION P1001(C-13)
0
D1270 L1270
2 1 4 3 ERA22-04 100u
C1150 D1150 NC
100P AP01CV2 5 14 1 2
3 2
F1180 - C1270 C1271
VSF0243C16 LB1123 50V120 0.01
LB1120 0 C1262 L1260
220P 22u
0 V1
4 15
C1300
0.1 D1260 C1260 C1261
21DQ06FC4
C1122 LB1124 10V1800 10V1000
1000P 0

3 16
D1301 D1300 C1124 IP1280
D ERA15-08V5 ERA15-08V5 1000P R1154
3.9M
VSF0015A10T
R1200 D1200
2.7 MA185
V2
R1153 2 17 1 2
D1180 4.7M
R1180 C1280 C1282
10K MA4220H 10V390 0.01
D1280
11EQS06
IC1150 C1114 D1182
35V47 MA7300B 18
STRM6559LF 16.7
5 C1281
0.01


-500
1

C DRIVE
START O.V.P LATCH LB1150 R1183 Q1200
0 VLP0056 1500 PC123FY2
2 R1201
2200 R1207
14.3 5.9 2700
REG 4 1
D1183 C1201 R1203 R1206 R1205
R1151 1SS254 8200P R1202 560 2700 6800
0.3 0 330 1.3 4.8 270
7 TRIGER T.S.D O.S.C O.C.P 4 3 2
R1152 R1150
470 0.82 IC1200
HA17431PA

B

C A R
4.5 2.5
6 3
1.3 C1202 R1204
0.1 2700



D1181
R1181 MA700
100
NOTE:THE MEASURMENT MODE OF THE DC VOLTAGE ON THIS DIAGRAM IS STOP MODE.
R1182 C1180 C1181
A 120K 6V330 1000P
NOTE1:WHEN MEASURE THE VOLTAGE OR WAVEFORM ON THE POWER TRANSFORMER
CIRCUIT,SET THE GND TERMINAL OF MEASURING POINT AS FOLLOWS.
PRIMARY SIDE.........
IMPORTANT SAFETY NOTICE: SECONDARY SIDE... NOTE:DO NOT USE ANY PART NUMBER SHOWN ON THIS
COMPONENTS IDENTIFIED WITH THE MARK HAVE THE SPECIAL CHARACTERISTICS FOR SAFETY. NOTE2:THE DC VOLTAGE INDICATED IN PRIMARY SIDE IS SHOWN THE VOLTAGE WHEN SCHEMATIC DIAGRAM FOR ORDERING.WHEN YOU
WHEN REPLACING ANY OF THESE COMPONENTS,USE ONLY THE SAME TYPE. INPUT AC IS 220V. ORDER A PART,PLEASE REFER TO PARTS LIST.

1 2 3 4 5 6 7 8 9 10