Text preview for : SERVTOOL.PDF part of Nokia 3210 3210 part#1



Back to : 3210_1.zip | Home

PAMS Technical Documentation NSE­8/9 Series Transceivers

Service Tools

Issue 1 07/99

NSE­8/9 Service Tools

PAMS Technical Documentation

CONTENTS Page No
Service Interface Cable TDS­7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Jig MJS­13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flash Loading Adapter FLA­5 (Sales Pack) . . . . . . . . . . . . . . . . . . . . . . Flash Prommer FPS­4S (Sales Pack) . . . . . . . . . . . . . . . . . . . . . . . . . . . Security Box TDF­4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Audio Box JBA­4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modular Cable XMS­3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warranty Transfer Tool SCW­1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Cable ADS­1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D15­D15 Cable AXS­5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Cable PCC­1B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF Coaxial Test Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MBUS Cable DAU­9S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Test Cable SCB­5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Cable PCS­1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modular T­adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SW Security Device PKD­1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dongle/Flash Device FLS­1 (Sales Pack) . . . . . . . . . . . . . . . . . . . . . . . . 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Page 2

Issue 1 07/99

PAMS Technical Documentation

NSE­8/9 Service Tools

Service Interface Cable TDS­7
The Service interface cable is used to flash and tune the phone without disassembling it.

Product Code Service Interface Cable TDS­7: View of TDS­7 07750160

Note: The nominal supply voltage forTDS­7 is 9­15VDC

Issue 1 07/99

Page 3

NSE­8/9 Service Tools

PAMS Technical Documentation

Module Jig MJS­13
The Module Jig MJS­13 is used for component level repair of the system module. Product Code Module Jig MJS­13: View of MJS­13 0770158

Note:

The nominal supply voltagerange for MJS­13 is 9­15 V.

Page 4

Issue 1 07/99

PAMS Technical Documentation

NSE­8/9 Service Tools

Flash Loading Adapter FLA­5 (Sales Pack)
The Flash Loading Adapter FLA­5 is used with the Service Battery BBD­3 and Service Cable SCH­5. Power is supplied to FLA­5 from the Flash Security Box TDF­4 via the DC cable PCC­1B, (The PCC­1B cable can be replaced with a Travel Charger ACH­6), and is connected to the Flash Prommer FPS­4S with the cable AXS­5. The sales pack includes: ­ Flash Loader Adapter FLA­5 ­ Service cable SCH­5 ­ D15 ­ D15 Cable AXS­5 ­ Installation software for FPS­4 Product Code Flash Loading Adapter FLA­5: View of FLA­5 0770085 0770085 0730098 0730091 8400041

Issue 1 07/99

Page 5

NSE­8/9 Service Tools

PAMS Technical Documentation

Flash Prommer FPS­4S (Sales Pack)
The Flash Prommer FPS­4S is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once. The sales pack includes: ­ Charger ACL­3E ­ Printer Cable ­ D9 ­ D9 Cable AXS­4 ­ Installation software for FPS­4 Product Code Flash Prommer FPS­4: View of FPS­4S 0750090 0680015 0730029 0730090 8400041

Page 6

Issue 1 07/99

PAMS Technical Documentation

NSE­8/9 Service Tools

Security Box TDF­4
The Security Box TDF­4 is required for updating MCU software, and infra red testing. Note1: TDF­4 is delivered in de­activated mode. Fill in the enclosed Activation Request Form, and fax to NMP Salo to get the activation code The infra red module JLP­1 is not included in the TDF­4 sales package

Note2: Product Code

Security Box TDF­4: View of TDF­4

0770106

Issue 1 07/99

Page 7

NSE­8/9 Service Tools

PAMS Technical Documentation

Service Audio Box JBA­4
The Service Audio Box JBA­4 is used between the module repair jig MJS­13 and audio test cables SCB­5 and ADS­1. Product Code Service Audio Box JBA­4: View of JBA­4 0770094

Page 8

Issue 1 07/99

PAMS Technical Documentation

NSE­8/9 Service Tools

Modular Cable XMS­3
The modular cable is used to connect the TDS­7 or MJS­13 to the FLA­5 (or 7) flash loading adapter. This enables flashing of the phone. The XMS­3 is also used when flashing with the Point Of Sales (POS) device FLS­2. Product Code Modular Cable XMS­3: View of XMS­3 0730174

Issue 1 07/99

Page 9

NSE­8/9 Service Tools

PAMS Technical Documentation

Warranty Transfer Tool SCW­1
The Warranty Transfer Tool is used to connect two phones and enables transfer of user data (picture messages,T9 user dictionary etc.) from one phone to another. Two tools are required to perform Warranty Transfer. The tool is also used for the Point Of Sales (POS) flash device FLS­2. Product Code Warranty Transfer Tool SCW­1 View of SCW­1 0770161

Page 10

Issue 1 07/99

PAMS Technical Documentation

NSE­8/9 Service Tools

Audio Cable ADS­1
Audio cable is an adapter routing AF signals (MIC/EAR) from an 8 pin modular connector to two BNC connectors. Product code Audio Cable ADS­1: View of ADS­1 0730011

Issue 1 07/99

Page 11

NSE­8/9 Service Tools

PAMS Technical Documentation

D15­D15 Cable AXS­5
The D15­D15 Cable AXS­5 is used to connect two 15 pin D connectors. e.g. between FLA­5 and FPS­4S. Product Code D15­D15 Cable AXS­5: View of AXS­5 0730091

Page 12

Issue 1 07/99

PAMS Technical Documentation

NSE­8/9 Service Tools

DC Cable PCC­1B
The DC Cable PCC­1B is used e.g. to connect FLA­5 and TDF­4. Product Code DC Cable PCC­1B: View of PCC­1 0770053

Issue 1 07/99

Page 13

NSE­8/9 Service Tools

PAMS Technical Documentation

RF Coaxial Test Cable
The RF Coaxial cable is used to connect the transceiver to external measuring equipment during servicing.
Note: Typical attenuation at 900MHz is 0.9dB (with MJS­13 & TDS­7) Typical attenuation at 1800MHz is 1.45dB (with MJS­13 & TDS­7)

Product Code RF Coaxial Cable View of RF­Coax Test Cable 4626009

Page 14

Issue 1 07/99

PAMS Technical Documentation

NSE­8/9 Service Tools

MBUS Cable DAU­9S
The MBUS Cable DAU­9S has a modular connector, and is used for data communication with the phone for connecting TDS­7 and MJS­13 to a PC.

MBUS Cable DAU­9S: View of DAU­9S

0730108

Issue 1 07/99

Page 15

NSE­8/9 Service Tools

PAMS Technical Documentation

Audio Test Cable SCB­5
The Audio Test Cable is used to connect the phones headset to the Service Audio Box JBA­4, supplying Mic/Ear signals to external test devices.

MBUS SCB­5: View of SCB­5

0775211

Page 16

Issue 1 07/99

PAMS Technical Documentation

NSE­8/9 Service Tools

Power Cable PCS­1
The Power Cable PCS­1 is used to connect the module jigs MJS­13 and service interface TDS­7 to an external power supply. Product Code Power Cable PCS­1: View of PCS­1 0730012

Issue 1 07/99

Page 17

NSE­8/9 Service Tools

PAMS Technical Documentation

Modular T­adapter
The modular T­adapter is a suitable branching unit to provide the needed parallel modular connections. Used for warranty transfer between two phones. Product Code Modular T­adapter: View of Modular T­adapter 4626134

Page 18

Issue 1 07/99

PAMS Technical Documentation

NSE­8/9 Service Tools

SW Security Device PKD­1
SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Whitout the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.

Caution: Make sure thet you have switched off the PC and the printer before making connections! Caution: Do not connected the PKD­1 to the serial port. You may damage your PKD­1!
Product Code SW Security Device PKD­1: View of SW Security Device 0750018

Issue 1 07/99

Page 19

NSE­8/9 Service Tools

PAMS Technical Documentation

Dongle/Flash Device FLS­1 /2 (Sales Pack)
FLS­1/2 are dongle and flash devices incorporated into one package, developed specifically for POS use. Product Code FLS­1 Sales Pack ­APAC FLS­1 Sales Pack ­ Europe/Africa FLS­2 Sales Pack ­APAC/Europe /APAC View of FLS­1 /2 0081290 0081291 0081311

Sales Pack Contents

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á Á Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Á ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁ
Part No. 0750130 0730163 0770177 0770176 0774120 0774123 0275405 Description FLS­1 Flash Device. AXS­4U Cable. Disk­ Installation package,16bit Dongle Drivers. Disk ­ Installation package, 32bit Dongle Drivers. Disk ­ Installation package for the FLE­5 Drivers. Disk ­ Remote Update Application Installation Package. Installation and User Guide 0275404 Registration Request Form Page 20

The picture overleaf shows how to connect the FLS­1 and 2 devices and associated cables to the PC and Product/Phone.

Issue 1 07/99

PAMS Technical Documentation FLS­1 Connection Diagram with TDS­7
Note: TDS­7 required to flash with FLS­1

NSE­8/9 Service Tools

1. FLS­1 (connects to parallel port) 4 2 1 3 4 PC with WinTesla Software
TDS­7

3 AXS­4U

2

FLS­2 Connection Diagram with SCW­1
Note: With SCW­1, flashing requires just a phone with battery

1 FLS­2 connects to parallel port 4 2 SCW­1 Flash & Warranty
transfer tool

1 2

3 AXS­4U 4 PC with WinTesla
software

3

Issue 1 07/99

Page 21

NSE­8/9 Service Tools

PAMS Technical Documentation

[This page intentionally left blank]

Page 22

Issue 1 07/99