Text preview for : MON02-001.pdf part of samsung all service bulletin monitor samsung - 2of3 zip



Back to : service_samsung02.zip | Home

SERVICE BULLETIN
Product: CRT MONITOR Model: AQ17HS/IS, AQ19IS/MS SyncMaster 700IFT, 750P, 900IFT, 950P Bulletin No.: MON02-001 (01-C/M-E0050) Bulletin Date: October 24, 2001 ECN Date: October 24, 2001

SUBJECT: DY-Wire Clamp Change_________________________________________ Background: The DY-Wire of the SyncMaster 700IFT, 750P, 900IFT, and 950P CRT monitors can cause arcing and other damage. Cause: The DY-wire can touch the sharp edge of the high voltage FET heat sink. This can cause the wire shield to peel off thus causing an arc. Change the routing method and clamp shape. This should be checked on all monitors manufactured before November 2001. (Refer to pictures on page 2 and 3).

Solution:

Application Date: November 1, 2001

ORIGINAL
Location No.
Cable Clamp

NEW
Description Part No.
6502-001058

Part No.
6502-000135

Description
DAWH-50N,ID16.6,,NYLON6/6,NTR

DAWS-2NA,1D10, -, NTR, NYLON66

Revision (4-4-2002)

1

BEFORE CHANGE

Revision (4-4-2002)

2

AFTER CHANGE

Revision (4-4-2002)

3