Text preview for : MON02-009.pdf part of samsung all service bulletin monitor samsung - 2of3 zip



Back to : service_samsung02.zip | Home

SERVICE BULLETIN
Product: CRT MONITOR Model: PG22NS (SyncMaster 1200NF) SUBJECT: Sync Problem Background: An abnormal pulse may be sent to the micom by turning the power switch on and off rapidly and repeatedly. This can cause a mismatch between the control board and the micom, causing improper operation. Cause: Solution: CS228. Change the characteristics of capacitor CS228. Bulletin No.: MON02-009 (02-C/M-E0080) Bulletin Date: August 26, 2002 ECN Date: August 21, 2002

Application Date: August 20, 2002

ORIGINAL
Location No.
CS228

NEW
Description Part No.
2305-000412

Part No.
2305-000665

Description
C-FILM, MPEF; 470nF, 5%, 63V

C-FILM, MPEF; 100nF, 5%, 63V

Revision (9-3-2002)

1