Text preview for : Sony DSC-P52 Secc 6 Ajus.pdf part of sony DSC-P52 sony DSC-P52 service manual
Back to : Sony DSC-P52.part1.rar | Home
DSC-P52
Ver 1.1 2003. 09
Revision History
SECTION 6 ADJUSTMENTS
ADJ
Link
Before starting adjustment
Adjusting items when replacing main parts and boards
SERVICE MODE
APPLICATION FOR ADJUSTMENT (SEUS) SERVICE MODE
ADJUSTMENT
PREPARATIONS BEFORE ADJUSTMENT INITIALIZATION OF 0E, 2F, 4F, 6F PAGE DATA VIDEO SYSTEM ADJUSTMENTS CAMERA SYSTEM ADJUSTMENTS LCD SYSTEM ADJUSTMENT SYSTEM CONTROL SYSTEM ADJUSTMENT
Contents of LEVEL 2 and LEVEL 3 Service Manual
CONTENTS 1. SERVICE NOTE 2. DISASSEMBLY 3. BLOCK DIAGRAMS 4. PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS LEVEL 2 a a OVERALL, CAMERA, FRONT/LCD, POWER ST-82, JK-256, RL-060, UA-003 BOARD, CONTROL SWITCH BLOCK (SW-392), FP-643 FLEXIBLE EXPLODED VIEWS ELECTRICAL PARTS LEVEL 3 SY-91 BOARD
5. REPAIR PARTS LIST
a (SY-91 BOARD)
9-876-248-51
Sony EMCS Co.
2003I1600-1 ©2003.9 Published by DI CS Strategy Div.
DSC-P52
TABLE OF CONTENTS 6. ADJUSTMENT
1. Before starting adjustment ··············································· 6-1 1-1. Adjusting items when replacing main parts and boards. · 6-2 6-1. ADJUSTMENT ······························································· 6-3 1-1. PREPARATIONS BEFORE ADJUSTMENT ················· 6-3 1-1-1. List of Service Tools ························································ 6-3 1-1-2. Preparations ····································································· 6-4 1-1-3. Discharging of the flashlight power supply ····················· 6-4 1-1-4. Precaution ········································································ 6-6 1. Setting the Switch ···························································· 6-6 2. Order of Adjustments ······················································ 6-6 3. Subjects ··········································································· 6-6 4. Preparing the Flash Adjustment Box ······························· 6-7 1-2. INITIALIZATION OF 0E, 2F, 4F, 6F PAGE DATA ··············································································· 6-8 1-2-1. INITIALIZATION OF 2F PAGE DATA ························· 6-8 1. Initializing the 2F Page Data ··········································· 6-8 2. 2F Page Table ·································································· 6-8 1-2-2. Initializing the 4F Page Data ··········································· 6-9 1. Initializing the 4F Page Data ··········································· 6-9 2. 4F Page Table ·································································· 6-9 1-2-3. Initializing the 6F Page Data ········································· 6-10 1. Initializing the 6F Page Data ········································· 6-10 2. 6F Page Table ································································ 6-10 1-2-4. INITIALIZATION OF 0E PAGE DATA ······················· 6-12 1. Initializing the 0E Page Data ········································· 6-12 2. 0E Page Table ································································ 6-12 1-3. VIDEO SYSTEM ADJUSTMENTS ····························· 6-13 1. Video Output Level Adjustment (SY-91 board) ············ 6-13 1-4. CAMERA SYSTEM ADJUSTMENTS ························ 6-14 1. Data Setting during Camera System Adjustments ········ 6-14 2. HALL Adjustment ························································· 6-14 3. Flange Back Adjustment ··············································· 6-15 (Using Minipattern Box) ·············································· 6-15 4. Flange Back Check ························································ 6-16 5. Picture Frame Setting ···················································· 6-17 6. F No. Standard Data Input ············································· 6-18 7. Mechanical Shutter Adjustment ···································· 6-18 8. Light Value Adjustment ················································· 6-19 9. Mixed Color Cancel Adjustment ··································· 6-19 10. Auto White Balance 3200K Standard Data Input ········· 6-20 11. Auto White Balance 3200K Check ······························· 6-21 12. Auto White Balance 5800K Standard Data Input ········· 6-22 13. Auto White Balance 5800K Check ······························· 6-23 14. CCD Linearity Check ···················································· 6-24 15. Color Reproduction Adjustment ···································· 6-25 16. Color Reproduction Check ············································ 6-26 17. CCD White Defect Compensation Check ····················· 6-27 18. CCD Black Defect Compensation Check ····················· 6-28 19. Strobe Adjustment ························································· 6-29 20. Auto Focus Illumination Check ···································· 6-30 1-5. LCD SYSTEM ADJUSTMENT ··································· 6-31 1. LCD Initial Data Input (1) ············································· 6-31 2. LCD Initial Data Input (2) ············································· 6-32 3. VCO Adjustment (SY-91 board) ··································· 6-32 4. Bright Adjustment (SY-91 board) ·································· 6-33 4-1. Adjustment without Using Oscilloscope ······················· 6-33 4-2. Adjustment Using Oscilloscope ···································· 6-33 5. Contrast Adjustment (SY-91 board) ······························ 6-34 5-1. Adjustment without Using Oscilloscope ······················· 6-34 5-2. Adjustment Using Oscilloscope ···································· 6-34 6. V COM Level Adjustment (SY-91 board) ····················· 6-35 6-1. Adjustment without Using Oscilloscope ······················· 6-35 6-2. Adjustment Using Oscilloscope ···································· 6-35 7. V COM Adjustment (SY-91 board) ······························· 6-36 8. White Balance Adjustment (SY-91 board) ···················· 6-36 1-6. SYSTEM CONTROL SYSTEM ADJUSTMENT ········ 6-37 1. Battery End Check (SY-91 board) ································· 6-37 6-2. SERVICE MODE ·························································· 6-38 2-1. APPLICATION FOR ADJUSTMENT (SEUS) ············ 6-38 2-1-1. Using Method of SEUS ················································· 6-38 1. Connection ····································································· 6-38 2. Operation ······································································· 6-38 2-1-2. Precaution on Use of SEUS ··········································· 6-38 2-2. SERVICE MODE ·························································· 6-39 1. Setting the Test Mode ···················································· 6-39 2. Bit value discrimination ················································ 6-39 3. Switch check (1) ···························································· 6-40 4. Switch check (2) ···························································· 6-40 5. LED check ····································································· 6-40 6. Lens Shutter check ························································ 6-40 * Color reproduction frame and AF illumination frame are shown on page 6-41.
--2--
DSC-P52
COVER
1. Before starting adjustment
SECTION 6 ADJUSTMENTS
EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct. Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.
Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board is replaced.
(Machine before starting repair) PC PC (Machine after a board is replaced)
Save the EVR data to a personal computer.
Download the saved data to a machine.
Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM to the replaced board.
Remove the EEPROM and install it.
(Former board)
(New board)
Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)
Download the data.
Save the data. (The same model of the same destination)
After the EVR data is saved and downloaded, check the respective items of the EVR data. (Refer to page 6-2 for the items to be checked.)
6-1
DSC-P52
COVER
1-1. Adjusting items when replacing main parts and boards.
When replacing main parts, adjust the items indicated by z in the following table. Replaced parts Block replacement Parts replacement Board EEPROM replacement replacement
SY-91 board IC802 (Timing generator) (LCD)
SY-91 board IC801 (RGB drive) (LCD)
SY-91 board IC301 (CAMERA DSP)
SY-91 board IC901 (S/H, AGC,A/D)
SY-91 board IC351 (CCD imager)
SY-91 board IC601 (Video amp.)
Initialization of 0E, Initialization of 0E, 2F, 4F, 6F 2F, 4F, 6F page data page data Video Video output level adj. HALL adj. Flange back adj. F No. standard data Input Mechanical shutter adj. Light value adj. Mixed color cancel adj. Camera AWB 3200K standard data input AWB 5800K standard data input CCD linearity check Color reproduction adj. CCD white defect compensation check CCD black defect compensation check Strobe adj. Auto focus illumination check LCD initial data input VCO adj. Bright adj. LCD Contrast adj. V COM level adj. V COM adj. White balance adj. System control Battery end check
LCD block Back light unit
Adjustment Section
Adjustment
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
z z z z z z z z z
z z z z
z z z z z z z
Table. 6-1-1.
6-2
SY-91 board IC502 (EEPROM)
z z z z z z z z z z z z z z z z z z z z z z z z
LCD block LCD unit (LCD901)
SY-91 board (COMPLETE)
Parts unit (UA-003)
Flash unit (ST-82)
Lens device
Ver 1.1 2003. 09
DSC-P52
COVER
6-1. ADJUSTMENT
1-1. PREPARATIONS BEFORE ADJUSTMENT
· Vectorscope · AC power adapter
1-1-1. List of Service Tools · Oscilloscope · Color monitor · Regulated power supply · Digital voltmeter · Calculator which can hexadecimal calculation. Ref. No. J-1 J-2 J-3 J-4 J-5 J-6 J-7 J-8 J-9 J-10 J-11 Name Filter for color temperature correction (C14) Pattern box PTB-450 Color chart for pattern box Siemens star chart Clear chart for pattern box Mini pattern box Camera table Personal computer with Windows98/ME/2000/XP installed and with two USB ports USB cable Application for adjustment (SEUS) and HASP key Background paper
Usage Auto white balance adjustment/check J-6080-058-A White balance adjustment/check J-6082-200-A J-6020-250-A J-6080-875-A For checking the flange back J-6080-621-A J-6082-353-B For adjusting the flange back J-6082-384-A For adjusting the flange back
Parts Code
For connecting the personal computer Contact our service headquarter of each area how to get the application for adjustment (SEUS) and HASP key J-2501-130-A For adjusting the strobe
1-823-932-11
J-1
J-2
J-3
J-4
J-5
J-6
J-7
J-8
J-9
J-10
J-11
Fig. 6-1-1.
6-3
DSC-P52
1-1-2. 1) 2)
Preparations
Pattern box
Connect the equipment for adjustments according to Fig. 6-1-4. Start up the application for adjustment (SEUS).
Note1: Setting the "Forced Power ON Mode (Forced STILL Mode)" 1) Select page: 00, address: 01, and set data: 01. 2) Select page: 2F, address: 21, and write data: 03. The above procedure will enable the power (STILL mode) to be turned on with POWER switch (SY-91 board CN705) disconnected. After completing adjustments, be sure to exit the "Forced Power ON Mode". Note2: Setting the "Forced Power ON Mode (Forced PLAY Mode)" 1) Select page: 00, address: 01, and set data: 01. 2) Select page: 2F, address: 21, and write data: 04. The above procedure will enable the power (PLAY mode) to be turned on with POWER switch (SY-91 board CN705) disconnected. After completing adjustments, be sure to exit the "Forced Power ON Mode". Note3: Exiting the "Forced Power ON Mode" 1) Select page: 00, address: 01, and set data: 01. 2) Select page: 2F, address: 21, and write data: 00. 3) Select page: 00, address: 01, and set data: 00.
About 36cm
Front of the lens
Fig. 6-1-2.
1-1-3. Discharging of the flashlight power supply The capacitor which is used as power supply of flashlight is charged with 200V to 300V voltage. Discharge this voltage when opening the SY-91 board in order to protect service engineers from electric shock. Discharge procedure 1. Remove the power supply (AC power adaptor or battery). 2. Fabricate the discharging jig as shown in Fig. 6-1-3 locally by yourself. Connect the discharging jig to the positive (+) and negative () terminal of the flash voltage charge capacitor. Allow ten seconds to discharge the voltage.
Capacitor
Shorting jig (1k / 1w)
ST-82 board
Fig. 6-1-3.
6-4
DSC-P52
[CONNECTION OF EQUIPMENT]
Personal computer (with two USB ports)
USB2
HASP key
USB1 DC IN USB AC power adaptor
AC IN
Memory stick
Fig. 6-1-4.
6-5
DSC-P52
1-1-4. Precaution 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments. SETUP settings USB connect (SETUP2) ........................................ NORMAL MENU settings Camera ......................................................................... AUTO Switch settings ) 1. Mode dial ........................................................... STILL ( 2. ZOOM .................................................................... WIDE end 3. IMAGE SIZE ................................................................. 3.1M
2. Order of Adjustments Basically carry out adjustments in the order given.
Color bar chart (Color reproduction adjustment frame)
Yellow Cyan Green White Magenta Red
H
C
C=D
D
Blue
Yellow Cyan Green White Magenta Red Blue
Picture frame
V A B A= B 2 Fig. a Video terminal output waveform A Enlargement Fig. b LCD screen or under scan monitor TV picture
Difference in level
A
Adjust the camera position and direction to obtain the output waveform shown in Fig. a and the LCD screen or the monitor TV display shown in Fig. b.
Fig.6-1-5.
3. Subjects 1) Color bar chart (Standard picture frame) When performing adjustments using the color bar chart, adjust the picture frame as shown in Fig. 6-1-5. (Standard picture frame) 2) Clear chart (Color reproduction adjustment frame) Remove the color bar chart from the pattern box and insert a clear chart in its place. (Do not perform zoom operations during this time.) 3) Flange back adjustment chart Make the chart shown in Fig. 6-1-6 using A0 size (1189mm × 841mm) black and white vellum paper.
White 841mm Black
1189mm
Fig. 6-1-6.
Note: Use matte vellum paper bigger than A0, and make sure the edges of the black and white paper joined together are not rough.
6-6
DSC-P52
4. Preparing the Flash Adjustment Box A dark room is required to provide an accurate strobe adjustment. If it is not available, prepare the flash adjustment box as given below; 1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2 sheets) 400 mm
woody board B (2 sheets) 370 mm
woody board C (1 sheet) 700 mm
513 mm
513 mm
700 mm
730 mm
700 mm
Fig. 6-1-7.
2) Apply black mat paint to one side of woody board A and B. 3) Attach background paper (J-2501-130-A) to woody board C. 4) Assemble so that the black sides and the background paper side of woody board A, B and C are internal. (Fig. 6-1-8.)
woody board A
woody board B
woody board A
woody board B woody board C
Fig. 6-1-8.
6-7
DSC-P52
COVER
1-2. INITIALIZATION OF 0E, 2F, 4F, 6F PAGE DATA
INITIALIZATION OF 2F PAGE DATA 2. 2F Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the 2F Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of 2F Page Data".)
1-2-1.
1. Initializing the 2F Page Data Adjusting page Adjusting Address 2F 00 to 7F
Address 00 to 20 21 22 to 7F
Initial value 00
Remark
Initializing Method: 1) Select page:00, address:01, and set data:01. 2) Click [Page Edit] on the SEUS screen to display the SEUS PAGE EDIT screen. 3) Click [Page] to display the INPUT PAGE screen, and input "2F". 4) Click [Preset Data Read] on the SEUS PAGE EDIT screen to display the INPUT SETID screen. 5) Input "03" and click [OK] to read the preset data. 6) On the SEUS PAGE EDIT screen, change the data of the "Fixed data-2" address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they are different in destination. When changing the data, copy the data built in the same model. If copy the data built in the different model, the camera may not operate.
Test mode Fixed data-1 Table. 6-1-2.
7) 8) 9)
Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value. Click [Write] to write the initializing data to the EEPROM of the camera. Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 2F Page data Order Page Address Data Procedure 1 2 3 4 5 20 20 00 01 29 29 Write the data. Write the data. Check "Receive Paket Error" is displayed on the SEUS screen. Turn on the power. Click [Connect] on the SEUS screen.
6-8
DSC-P52
1-2-2.
Initializing the 4F Page Data
2. 4F Page Table
Note1: Fixed data-1: Initialized data. (Refer to "1. Initializing the 4F Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of 4F Page Data".)
1. Initializing the 4F Page Data
Note: If the 4F page data has been initialized, the following adjustments need to be performed again. 1) Video system adjustments 2) LCD system adjustments
Address 00 to 7E 80 81 82 83 84 85 86 87 88 89 8A 8B 8C to 91 92 93 94 95 98 to 9F A0 A1 to A2 A3 A4 A5 to A7 A8 A9 to AB AC AD AE AF
Initial value 4E FF 80 90 6D 16 08 87 8D 59 38 00 05 0C 9F 1F 80 24 00
Remark Fixed data-1 Fixed data (LCD) VCO adj. (LCD) V COM adj. (LCD) Bright adj. (LCD) Fixed data (LCD) V COM level adj. (LCD) White balance adj. Contrast adj. (LCD) Fixed data (LCD) Fixed data-1 Fixed data (LCD)
Adjusting page Adjusting Address
4F 00 to AF
Initializing Method: 1) Select page:00, address:01, and set data:01. 2) Click [Page Edit] on the SEUS screen to display the SEUS PAGE EDIT screen. 3) Click [Page] to display the INPUT PAGE screen, and input "4F". 4) Click [Preset Data Read] on the SEUS PAGE EDIT screen to display the INPUT SETID screen. 5) Input "03" and click [OK] to read the preset data. 6) On the SEUS PAGE EDIT screen, change the data of the "Fixed data-2" address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they are different in destination. When changing the data, copy the data built in the same model. If copy the data built in the different model, the camera may not operate.
7) 8) 9)
Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value. Click [Write] to write the initializing data to the EEPROM of the camera. Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 4F Page data Order Page Address Data Procedure 1 2 3 4 5 20 20 00 01 29 29 Write the data. Write the data. Check "Receive Paket Error" is displayed on the SEUS screen. Turn on the power. Click [Connect] on the SEUS screen.
Fixed data-1 Video output level adj. Fixed data-1 Fixed data (LCD) Fixed data-1 Fixed data-2 Fixed data-1 Recording counter (Hexadecimal) (Note2)
00 00 00 00
Table. 6-1-3.
Note2: Calculate the recording counter (N) using following equation. (Hexadecimal calculation) N = DAF + DAE × 100 + DAD × 10000 + DAC × 1000000
6-9
DSC-P52
1-2-3.
Initializing the 6F Page Data
2. 6F Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the 6F Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of 6F Page Data".)
1. Initializing the 6F Page Data
Note: If the 6F page data has been initialized, the following adjustments need to be performed again. 1) Camera system adjustments
Address Adjusting page Adjusting Address 6F 00 to FF 00 to 13 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F to 57 58 59
Initial value FF FF FF FF FF FF FF FF 14 40 20 EB 10 7D 00 00 00 00 1C 00 20 20 71 44 0A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 FF 5D 8F
Remark Fixed data-1 Auto focus illumination check
Initializing Method: 1) Select page:00, address:01, and set data:01. 2) Click [Page Edit] on the SEUS screen to display the SEUS PAGE EDIT screen. 3) Click [Page] to display the INPUT PAGE screen, and input "6F". 4) Click [Preset Data Read] on the SEUS PAGE EDIT screen to display the INPUT SETID screen. 5) Input "03" and click [OK] to read the preset data. 6) On the SEUS PAGE EDIT screen, change the data of the "Fixed data-2" address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they are different in destination. When changing the data, copy the data built in the same model. If copy the data built in the different model, the camera may not operate.
Flange back Adj.
7) 8) 9)
Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value. Click [Write] to write the initializing data to the EEPROM of the camera. Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 6F Page data Order Page Address Data Procedure 1 2 3 4 5 20 20 00 01 29 29 Write the data. Write the data. Check "Receive Paket Error" is displayed on the SEUS screen. Turn on the page. Click [Connect] on the SEUS screen.
Fixed data-1 HALL adj.
6-10
DSC-P52
6F page Address Remark Initial value 5A 13 HALL adj. 5B 5B 5C 75 5D 5D 5E to 5F Fixed data-1 60 00 F No. standard data input 61 00 62 00 63 00 64 00 65 30 Light value adj. 66 FE 67 6D 68 68 HALL adj. 69 to 6A Fixed data-1 6B FF HALL adj./F No. standard data input/ 6C 00 Mechanical shutter adj. 6D 00 6E 00 Mixed color cancel adj. 6F 00 70 44 AWB 3200K standard data input 71 A3 72 16 73 F5 74 42 75 C1 76 18 77 15 78 00 79 00 7A 00 7B 00 7C F5 7D 0C 7E 00 7F 00 80 00 81 00 82 F1 83 24 84 00 85 00 86 00 87 05 88 2B AWB 5200K standard data input 89 4A 8A 22 8B 62 8C 29 8D DA 8E 23 8F D1 90 00 91 00 92 00 Address 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 Initial value 00 09 04 00 00 00 00 FB FD 00 00 00 05 28 C8 60 00 01 F4 81 C0 09 04 8D 92 7F C0 FD F4 A5 8B 99 55 02 25 76 10 6B 0F F6 0F F7 0F F2 0F F7 00 00 00 00 00 30 1B 12 Remark AWB 5200K standard data input
Color reproduction adj.
AWB 3200K standard data input AWB 5800K standard data input AWB 3200K standard data input AWB 5800K standard data input AWB 3200K standard data input Fixed data-1 Strobe adj. Mechanical shutter adj.
6-11
DSC-P52
6F page 1-2-4. Address Remark Initial value CA 0D Mechanical shutter adj. CB 08 CC 80 CD 88 CE 98 CF 90 D0 88 D1 00 D2 00 D3 00 D4 00 D5 00 D6 00 D7 14 D8 FF Strobe adj. D9 FF DA FF DB 00 DC 00 DD 00 DE 00 DF 00 E0 00 E1 00 E2 00 E3 00 E4 00 E5 00 E6 00 E7 00 E8 00 E9 00 EA 00 EB 00 EC 00 ED 00 EE 00 EF 00 F0 to FF Fixed data-1 INITIALIZATION OF 0E PAGE DATA
1. Initializing the 0E Page Data Adjusting page Adjusting Address 0E 00 to FF
Initializing Method: 1) Select page:00, address:01, and set data:01. 2) Click [Page Edit] on the SEUS screen to display the SEUS PAGE EDIT screen. 3) Click [Page] to display the INPUT PAGE screen, and input "0E". 4) Click [Preset Data Read] on the SEUS PAGE EDIT screen to display the INPUT SETID screen. 5) Input "00" and click [OK] to read the preset data. 6) Click [Write] to write the initializing data to the EEPROM of the camera. 7) Click [Close] to close the SEUS PAGE EDIT screen. Processing after Completing Initializing of 0E Page data Order Page Address Data Procedure 1 2 3 4 5 20 20 00 01 29 29 Write the data. Write the data. Check "Receive Paket Error" is displayed on the SEUS screen. Turn on the power. Click [Connect] on the SEUS screen.
2. 0E Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the 0E Page Data".)
Address F0 to FF Fixed data-1
Remark
Table. 6-1-5.
Table. 6-1-4.
6-12
DSC-P52
COVER
1-3. VIDEO SYSTEM ADJUSTMENTS
1. Video Output Level Adjustment (SY-91 board) Adjust the sync level of the composite video signal output. Mode PLAY ( ) Signal Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value Arbitrary Video terminal of AV OUT jack (75 terminated) Oscilloscope 4F A0 Sync level: A=286 ± 5mV (NTSC mode) A=300 ± 5mV (PAL mode) Burst level: B=286 ± 30mV (NTSC mode) B=300 ± 30mV (PAL mode)
SETUP setting: VIDEO OUT (SETUP 2) ............................ NTSC (NTSC mode) .................................. PAL (PAL mode) Adjusting method: Order Page Address Data Procedure 1 00 01 01 Set the data. 2 3 4 5 6 7 8 9 10 60 4F 40 4F 4F C1 02 F1 A0 A0 03 04 Read the data, and check it is "01". Write the data. Write the data. Change the data and set the sync level (A) to the specified value. Write the data. Check that the burst level (B) satisfies the specified value. 00 00 00 Write the data. Write the data. Set the data.
4F 40 00
02 F1 01
B A
H
Fig.6-1-9.
6-13
DSC-P52
COVER
1-4. CAMERA SYSTEM ADJUSTMENTS
2. HALL Adjustment For detecting the position of the lens iris, adjust the hall AMP gain and offset. Mode STILL ( ) Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value1 Specified Value2 Specified Value3 Arbitrary Data of page:10, address: 07 Data of page: 6F, address: 6B 6F 58 to 5D, 68, 6B to 6D 00 12 to 1A 7F to 87
Before perform the camera system adjustments, check that the specified values of "VIDEO SYSTEM ADJUSTMENT" are satisfied. 1. Data Setting during Camera System Adjustments Perform the following data setting before the camera system adjustments.
Note1: When the power is turned off, some data settings will be released. So perform this data setting again when the power is turned off.
Order Page Address Data 1 2 3 4 5 6 7 8 9 10 00 4F 4F 2F 60 60 6F 4F 7F 75 01 0F 02 21 C1 6C 00 01 68 0A 01 01 02 03 01 20 20 00 04
Procedure Set the data. Write the data. Write the data. Set the data. Read the data, and check it is "02". Write the data. Write the data. Write the data. Write the data. Write the data.
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Adjusting method: Order Page Address Data Procedure 1 Check that "1. Data Setting during Camera System Adjustments" is performed. 2 3 4 5 6 00 60 60 60 01 01 02 01 00 01 6D Set the data. Write the data. Wait for 1 sec. Read the data, and check it is "01". (Note2) Write the data.
After completing the camera system adjustments, release the data setting. Order Page Address Data Procedure 1 00 01 01 Set the data. 2 3 4 5 6 7 8 9 4F 4F 2F 4F 7F 75 00 0F 02 21 01 68 0A 01 00 00 00 00 40 00 00 Write the data. Write the data. Write the data. Write the data. Write the data. Write the data. Set the data. Initialize the 0E page data. (Note2)
Note2: The adjustment data will be automatically input to page: 6F, address: 58 to 5D, 68, 6B to 6D.
Checking method: Order Page Address Data 1 2 3 4 5 6 6F 60 10 60 60 10 6B 01 07 01 01 07 00 03 01
Procedure Read the data, and check it satisfies the specified value 1. Write the data. Read the data, and check it satisfies the specified value 2. Write the data. Write the data. Read the data, and check it satisfies the specified value 3.
Note2: Refer to "1-2-4. INITIALIZATION OF 0E PAGE DATA".
Processing after Completing Adjustments: Order Page Address Data Procedure 1 60 01 00 Write the data. 2 If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
6-14
DSC-P52
3. Flange Back Adjustment (Using Minipattern Box) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. Mode STILL ( ) Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value1 Specified value2 Siemens star chart with ND filter for the minipattern box (Note1) Data of page: 6F, address: 24, 3E 6F 18 to 3E 00 0A to 40
Adjusting method: Order Page Address Data 1
Procedure Check that "1. Data Setting during Camera System Adjustments" is performed. Set the data. Write the data. Write the data. Wait until the movement of the lens stops. Read the data, and check it is "01". (Note3) Read the data, and check it satisfies the specified value 1. Read the data, and check it satisfies the specified value 2.
2 3 4 5 6 7 8
00 60 60
01 01 01
01 13 27
60 6F 6F
02 3E 24
Note1: Dark siemens star chart. Note2: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Note3: The adjustment data will be automatically input to page:6F, address: 18 to 3E
Preparations: 1) The minipattern box is installed as shown in the following figure.
Note: The attachment lenses are not used.
Processing after Completing Adjustments: Order Page Address Data Procedure 1 60 01 00 Write the data. 2 3 4 5 Click [Disconnect]. Tuen off the power turn on again. Perform "Flange Back Check". If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
2) 3) 4) 5)
Install the minipattern box so that the distance between it and the front of the lens of the camera is less than 3cm. Make the height of the minipattern box and the camcorder equal. Check that the output voltage of the regulated power supply is the specified voltage. Check that the center of the siemens star chart and center of the exposure screen coincide.
Specified voltage: The specified voltage varies according to the minipattern box, so adjust the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box Camera Camera table Regulated power supply Output voltage : Specified voltage ±0.01Vdc Output current : more than 3.5A
Red (+) Black () Yellow (SENS +) White (SENS ) Black (GND) Need not connected
Fig.6-1-10.
6-15
DSC-P52
4. Flange Back Check Mode Subject STILL ( )
Measurement Point Measuring Instrument Specified Value
Siemens star (1.0 m from the front of the lens) (Luminance : approx. 300 lux) Check operation on TV monitor The lens is focused.
Switch setting: CAMERA setting (Menu setting) ................................ AUTO Checking method: 1) Place the siemens star 1.0m from the front of the lens. 2) Select page: 5F, address: 3D, read the data, and memorize it. Then set data: 50. 3) Select page: 7B, address: 98, read the data, and memorize it. Then set data: A0. 4) Shoot the siemens star with the zoom TELE end. 5) To open the IRIS, decrease the luminous intensity to the siemens star up to a point before noise appear on the image. 6) Observe the TV monitor and check that the lens is focused. 7) Select page: 60, address: 2C, and set data: 01. 8) Shoot the siemens star with the zoom WIDE end. 9) Observe the TV monitor and check that the lens is focused. Processing after Completing Adjustments: 1) Select page: 5F, address: 3D, and set the data memorized at step 2. 2) Select page: 7B, address: 98, and set the data memorized at step 3. 3) Select page: 60, address: 2C, and set data: 00.
6-16
DSC-P52
5. Picture Frame Setting Mode Subject STILL ( )
Measurement Point Measuring Instrument Specified Value
Color bar chart and clear chart (Standard picture frame) About 36 cm from the front of the lens Video terminal of A/V OUT jack Oscilloscope and TV monitor A=C=B/2, E=F
Check on an oscilloscope 1. Horizontal period
A=C= B 2
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Setting method: Order Page Address Data Procedure 1 Check that "1. Data Setting during Camera System Adjustments" is performed. 2 3 Shoot the color bar chart. Adjust the direction and distance between the pattern box and camera, and set the picture frame to the specified position. Remove the color bar chart and set the clear chart. Check that the whole of the screen is white. If not, adjust the direction and distance slightly. 10 10 60 44 45 2C 01 Read the data, and this data named YH. Read the data, and this data named YL. Write the data. Perform the following adjustments.
A B
C
4 5
6 7 8 9
Fig. 6-1-11. 2. Vertical period
E E=F F
How to reset the focus when they deviated: If the zoom and focus deviated due to some reason reset them in the following method. Order Page Address Data Procedure 1 60 2C 01 Write the data. 2 3 4 5 6 7 8 9 60 60 60 60 60 90 91 92 93 01 00 00 YL YH 79 Write the data. Write the data. Write the data. Note Write the data. Note Write the data. Wait until the movement of the lens stops. Read the data, and check it is "01". Write the data.
V
Fig. 6-1-12. Check on the monitor TV (Underscanned mode)
A B C
60 60
07 01
00
Note: YH and YL are the data read in the "Setting method".
Color bar chart picture frame
Effective picture frame
Fig. 6-1-13.
6-17
DSC-P52
6. F No. Standard Data Input Adjusted the dispersion of the iris to every to every F number, and compensate the exposure. Mode STILL ( ) Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Clear chart (Standard picture frame) Data of page: 6F, address: 6B 6F 60 to 64, 6B to 6D 00
7. Mechanical Shutter Adjustment Adjust the dispersion of the opening/closing time and the closing loss rate of the mechanical shutter. and compensate the exposure. Mode STILL ( ) Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Clear chart (Standard picture frame) Data of page: 6F, address: 6B 6F 6B to 6D, B8 to D7 00
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data Procedure 1 Check that "1. Data Setting during Camera System Adjustments" is performed. 2 Check the picture frame. If deviated, perform "5. Picture Frame Setting". Set the data. Write the data. Wait for 1 sec. Red the data, and check it is "01". (Note2) Read the data, and check it satisfies the specified value.
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data Procedure 1 Check that "1. Data Setting during Camera System Adjustments" is performed. 2 Check the picture frame. If deviated, perform "5. Picture Frame Setting". Set the data. Write the data. Wait until the movement of the shutter stops. Read the data, and check it is "01". (Note2) Read the data, and check it satisfies the specified value.
3 4 5 6 7
00 60 60 6F
01 01 02 6B
01 BB
3 4 5 6 7
00 60
01 01
01 AD
60 6F
02 6B
Note2: The adjustment data will be automatically input to page: 6F, address: 60 to 64, 6B to 6D.
Note2: The adjustment data will be automatically input to page: 6F, address: 6B to 6D, B8 to D7.
Processing after Completing Adjustments: Order Page Address Data Procedure 1 60 01 00 Write the data. 2 If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".) Processing after Completing Adjustments: Order Page Address Data Procedure 1 60 01 00 Write the data. 2 If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
6-18
DSC-P52
8. Light Value Adjustment Adjust the standard LV value. Mode STILL ( Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value1 Specified value2
)
9. Mixed Color Cancel Adjustment Compensate the dispersion of the Cr and Cb filter. Mode STILL ( ) Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Color bar chart (Standard picture frame) Data of page: 6F, address: B5 6F 6E to 6F 00
Clear chart (Standard picture frame) Data of page: 10, address: 0C, 0D Data of page: 6F, address: 65 6F 65 to 67 0FE0 to 1020 2D to 58
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data 1
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data Procedure 1 Install the color bar chart. 2 Check that "1. Data Setting during Camera System Adjustments" is performed. Check the picture frame. If deviated, perform "5. Picture Frame Setting". 00 6F 60 60 60 6F 01 B5 01 01 02 B5 01 FF D7 D5 Set the data. Write the data. Write the data. Wait for 1 sec. Write the data. Wait for 1 sec. Read the data, and check it is "01". (Note2) Read the data, and check it satisfies the specified value.
Procedure Check that "1. Data Setting during Camera System Adjustments" is performed. Check the picture frame. If deviated, perform "5. Picture Frame Setting".
2
3
3 4 5 6 7 8 9
00 60 60 10 10
01 01 02 0C 0D
01 0D
Set the data. Write the data. Wait for 1 sec. Read the data, and check it is "01". (Note2) Read the data, and this data is named D0C. Read the data, and this data is named D0D. Calculate DLV using the following equation. (Hexadecimal calculation.) DLV = D0C × 100 + D0D Check that DLV satisfies the specified value1.
4 5 6 7 8 9 10 11
Note2: The adjustment data will be automatically input to page: 6F, address: 6E to 6F.
10 11 6F 65
Processing after Completing Adjustments: Order Page Address Data Procedure 1 60 01 00 Write the data. 2 Perform next adjustments. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
Read the data, and check it satisfies the specified value2.
Note2: The adjustment data will be automatically input to page: 6F, address: 65 to 67.
Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 60 01 00 Write the data. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
6-19
DSC-P52
10. Auto White Balance 3200K Standard Data Input Adjust the white balance standard data at 3200K. Mode STILL ( ) Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Clear chart (Standard picture frame) Data of page: 6F, address: B5 6F 70 to 87, B0, B2, B4 00
Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 3 60 60 37 01 00 00 Write the data. Write the data. Perform next adjustments. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data Procedure 1 Install the Clear chart. 2 Check that "1. Data Setting during Camera System Adjustments" is performed. Check the picture frame. If deviated, perform "5. Picture Frame Setting". 00 6F 60 60 60 60 60 60 60 60 60 60 60 60 6F 01 B5 02 37 01 38 01 02 01 02 37 01 02 01 B5 00 00 01 11 C1 01 FF Set the data. Write the data. 3200K standard data input (1) Read the data, and check it is "00". Write the data. Write the data. Read the data, and check it is "01". Write the data. Wait for 1 sec. Read the data, and check it is "01". (Note2) Write the data. 3200K standard data input (2) Read the data, and check it is "00". Write the data. Write the data. Wait for 3 sec. Read the data, and check it is "01". (Note2) Write the data. Read the data, and check it satisfies the specified value.
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
02 0B
Note2: The adjustment data will be automatically input to page: 6F, address: 70 to 87, B0, B2, B4.
6-20
DSC-P52
11. Auto White Balance 3200K Check Check that the white balance standard data at 3200K are inputted properly. Mode STILL ( ) Subject Measurement Point Measuring Instrument Specified value 1 Specified value 2 Specified value 3 Specified value 4 Specified value 5 Specified value 6 Specified value 7 Clear chart (Standard picture frame) Data of page: 10, address: 08, 09, 0A, 0B, 59, 5B Data of page: 6F, address: 74, 76, B5 R ratio = 3F00 to 4100 B ratio = 3F00 to 4100 R-Y data = 7A to 86 B-Y data = 7A to 86 R/G data = 20 to 60 B/G data = 10 to 40 00
Order Page Address Data 18
Procedure Calculate B ratio using the following equation (Hexadecimal calculation) B ratio = D0A × 100 + D0B Check that B ratio satisfies the specified value2.
19 20 21 22 23 24 25 10 10 60 6F 6F 6F 59 5B 01 74 76 B5 00
Read the data (R-Y data), and check it satisfies the specified value3. Read the data (B-Y data), and check it satisfies the specified value4. Write the data. 3200K standard data Check (2) Read the data (R/G data), and check it satisfies the specified value 5. Read the data (B/G data), and check it satisfies the specified value 6. Read the data, and check it satisfies the specified value 7.
Note: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data Procedure 1 Check that "1. Data Setting during Camera System Adjustments" is performed. 2 Check the picture frame. If deviated, perform "5. Picture Frame Setting". Set the data. Write the data. 3200K standard data Check (1) Write the data. Write the data. Wait for 1 sec. Read the data, and check it is "01". C1 Write the data. Wait for 1 sec. Read the data, and check it is "01". Read the data, and this data is named D08. Read the data, and this data is named D09. Calculate R ratio using the following equation (Hexadecimal calculation) R ratio = D08 × 100 + D09 Check that R ratio satisfies the specified value1. Read the data, and this data is named D0A. Read the data, and this data is named D0B.
Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 3 60 60 37 01 00 00 Write the data. Write the data. Perform next adjustments. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
3 4 5 6 7 8 9 10 11 12 13 14
00 6F 60 60 60 60 60 10 10
01 B5 37 01 38 01 02 08 09
01 FF 0D 11
15 16 17 10 10 0A 0B
6-21
DSC-P52
12. Auto White Balance 5800K Standard Data Input Adjust the white balance standard data at 5800K. Mode STILL ( ) Subject Filter Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Clear chart (Standard picture frame) Filter C14 for color temperature correction Data of page: 6F, address: B5 6F 88 to A3, B1, B3 00
Order Page Address Data 24 25 26 60 60 6F 02 01 B5 00
Procedure Read the data, and check it is "01". (Note2) Write the data. Read the data, and check it satisfies the specified value.
Note2: The adjustment data will be automatically input to page: 6F, address: 88 to A3, B1, B3.
Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 3 60 60 37 01 00 00 Write the data. Write the data. Perform next adjustments. If finish the camera system adjustments, perform "Processing after Completing Adjustments" of "13. Auto White Balance 5800K Check".
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data 1 2
Procedure Place the C14 filter for color temperature correction on the lens. Check that "1. Data Setting during Camera System Adjustments" is performed. Check the picture frame. If deviated, perform "5. Picture Frame Setting". Set the data. Write the data. Read the data, this data is named DA0, and memorize it. Write the data. Read the data, this data is named DA1, and memorize it. Write the data. Read the data, this data is named DA2, and memorize it. Write the data. Read the data, this data is named DA3, and memorize it. Write the data. 5800K standard data input (1). Write the data. Write the data. Read the data, and check it is "01". Write the data. Wait for 1 sec. Read the data, and check it is "01". (Note2)
3
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
00 6F 6F 6F 6F 6F 6F 6F 6F 6F 60 60 60 60 60 60 60 60
01 B5 A0 A0 A1 A1 A2 A2 A3 A3 37 01 38 01 02 01 37 01
01 FF
28
C8
60
00 07 11 C3
00 08 A5
Write the data. 5800K standard data input (2). Write the data. Write the data. Wait for 2 sec.
6-22
DSC-P52
13. Auto White Balance 5800K Check Check that the white balance standard data at 5800K are inputted properly. Mode STILL ( ) Subject Filter Measurement Point Measuring Instrument Specified value 1 Specified value 2 Specified value 3 Specified value 4 Specified value 5 Specified value 6 Specified value 7 Clear chart (Standard picture frame) Filter C14 for color temperature correction Data of page: 10, address: 08, 09, 0A, 0B, 59, 5B Data of page: 6F, address: 8C, 8E, B5 R ratio = 26C8 to 2AC8 B ratio = 5E00 to 6200 R-Y data = 70 to 90 B-Y data = 70 to 90 R/G data = 10 to 40 B/G data = 10 to 40 00
Order Page Address Data 17 18 10 0B
Procedure Read the data, and this data is named D0B. Calculate B ratio using the following equation. (Hexadecimal calculation.) B ratio = D0A × 100 + D0B Check that B ratio satisfies the specified value 2. Read the data (R-Y data), and check it satisfies the specified value 3. Read the data (B-Y data), and check it satisfies the specified value 4. Write the data. 5800K standard data Check (2). Read the data (R/G data), and check it satisfies the specified value 5. Read the data (B/G data), and check it satisfies the specified value 6. Read the data, and check it satisfies the specified value 7.
19 20 10 59
21
10
5B
22 23
60 6F
01 8C
00
Note1: Before perform this adjustment, perform "Auto White Balance 5800K Standard Data Input". Note2: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
24
6F
8E
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data 1
25
6F
B5
Processing after Completing Adjustments: Order Page Address Data Procedure 1 60 37 00 Write the data. 2 3 4 5 6 7 8 60 6F 6F 6F 6F 01 A0 A1 A2 A3 00 DA0 DA1 DA2 DA3 Write the data. Write the data. (Note3) Write the data. (Note3) Write the data. (Note3) Write the data. (Note3) Remove the C14 filter. Perform next adjustments. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
Procedure Place the C14 filter for color temperature correction on the lens. Check that "1. Data Setting during Camera System Adjustments" is performed. Check the picture frame. If deviated, perform "5. Picture Frame Setting". Set the data. Write the data. 5800K standard data Check (1). Write the data. Write the data. Read the data, and check it is "01". Write the data. Wait for 2 sec. Read the data, and check it is "01". Read the data, and this data is named D08. Read the data, and this data is named D09. Calculate R ratio using the following equation. (Hexadecimal calculation.) R ratio = D08 × 100 + D09 Check that R ratio satisfies the specified value1.
2
3
4 5 6 7 8 9 10 11 12 13 14
00 6F 60 60 60 60 60 10 10
01 B5 37 01 38 01 02 08 09
01 FF 13 11 C3
Note3: DA0, DA1, DA2, and DA3 are memorized data at "12. Auto White Balance 5800K Standard Data Input".
15 16 10 0A
Read the data, and this data is named D0A.
6-23
DSC-P52
14. CCD Linearity Check Data picking is done to keep output linearity of the CCD imager, even if the input level of CCD imager changes. Mode STILL ( ) Subject Specified value1 Specified value2 Clear chart (Standard picture frame) 97 to 103 97 to 103
Order Page Address Data 29 30 31 32 33 60 10 10 E1 80 81
Procedure Wait for 2 sec. Read the data, and check it is "08". Read the data, and this data is named D80. Read the data, and this data is named D81. Calculate DRG using the following equation (Hexadecimal calculation) DRGH = D80 × 100 + D81 Read the data, and this data is named D82. Read the data, and this data is named D83. Calculate DBG using the following equation (Hexadecimal calculation) DBGH = D82 × 100 + D83
Note: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data 1
34 35
10 10
82 83
Procedure Check that "1. Data Setting during Camera System Adjustments" is performed. Check the picture frame. If deviated, perform "5. Picture Frame Setting".
36
2
37 38 39 40 41 42 43 44 45 46
60 60 77 60 60 10 10
01 E1 72 01 E1 80 81
00 00 09 F9
Write the data. Write the data. Write the data. Wait for 2 sec. Write the data. Wait for 2 sec. Read the data, and check it is "08". Read the data, and this data is named D80. Read the data, and this data is named D81. Calculate DRG using the following equation (Hexadecimal calculation) DRGL = D80 × 100 + D81 Read the data, and this data is named D82. Read the data, and this data is named D83. Calculate DBG using the following equation (Hexadecimal calculation) DBGL = D82 × 100 + D83 Write the data. Write the data. Convert DRG0, DBG0, DRGH, DBGH, DRGL and DBGL to decimal number, and obtain DRG0', DBG0', DRGH', DBGH', DRGL' and DBGL'. Calculate R/G ratio (H), B/G ratio (H), R/G ratio (L) and B/G ratio (L), using the following equations (Decimal calculation) R/G ratio (H) = (DRGH' / DRG0') ×100 B/G ratio (H) = (DBGH' / DBG0') × 100 R/G ratio (L) = (DRGL' / DRG0') × 100 B/G ratio (L) = (DBGL' / DBG0') ×100
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
00 75 75 60 77 77 77 77 60 60 60 60 10 10
01 09 09 1F F7 F7 F2 F2 14 12 01 E1 80 81
01 04 80 42 02 90 9F F9
Set the data. Read the data, and memorize it. Write the data. Write the data. Read the data, and memorize it. Write the data. Read the data, and memorize it. Write the data. Write the data. Write the data. Wait for 2 sec. Write the data. Wait for 2 sec. Read the data, and check it is "08". Read the data, and this data is named D80. Read the data, and this data is named D81. Calculate DRG using the following equation (Hexadecimal calculation) DRG0 = D80 ×100 + D81 Read the data, and this data is named D82. Read the data, and this data is named D83. Calculate DBG using the following equation (Hexadecimal calculation) DBG0 = D82 × 100 + D83
47 48 49
10 10
82 83
50 51 52
60 60
01 E1
00 00
20 21 22
10 10
82 83
53
23 24 25 26 27 28
60 60 77 77 60
01 E1 72 72 01
00 00 30 F9
Write the data. Write the data. Read the data, and memorize it. Write the data. Wait for 2 sec. Write the data.
6-24
DSC-P52
Order Page Address Data 54
Procedure Check that R/G ratio (H) satisfies the specified value 1. (Decimal number) Check that B/G ratio (H) satisfies the specified value 1. (Decimal number) Check that R/G ratio (L) satisfies the specified value 2. (Decimal number) Check that B/G ratio (L) satisfies the specified value 2. (Decimal number)
15. Color Reproduction Adjustment Adjust the color Separation matrix coefficient so that proper color reproduction is produced. Mode STILL ( ) Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Color bar chart (Standard picture frame) Data of page: 6F, address: B5 6F A4 to AF 00
55
56
57
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Processing after Completing Adjustments: Order Page Address Data Procedure 1 60 12 00 Write the data. 2 3 4 5 6 7 8 60 60 75 77 77 77 14 1F 09 F7 F2 72 00 00 Write the data. Write the data. Write the data memorized at step 4. Write the data memorized at step 7. Write the data memorized at step 9. Write the data memorized at step 25. Perform next adjustments. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO VIDEO OUT (SET UP setting) .................................... NTSC Adjusting method: Order Page Address Data Procedure 1 Install the color bar chart. 2 Check that "1. Data Setting during Camera System Adjustments" is performed. Check the picture frame. If deviated, perform "5. Picture Frame Setting". Set the data. Write the data. Write the data. Write the data. Wait for 1 sec. Write the data. Wait for 2 sec. Write the data. Wait until the color of the screen stops changing. Read the data, and check it is "01". (Note2) Read the data, and check it satisfies the specified value.
3
4 5 6 7 8 9 10 11 12 13 14
00 6F 60 60 60 60
01 B5 01 12 12 01
01 FF AB 80 00 A9
60 6F
02 B5
Note2: The adjustment data will be automatically input to page: 6F, address: A4 to AF.
Processing after Completing Adjustments: Order Page Address Data Procedure 1 60 01 00 Write the data. 2 Perform next adjustments. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
6-25
DSC-P52
16. Color Reproduction Check Check that the color reproduction adjustment is done properly. Mode STILL ( ) Subject Measurement Point Measuring Instrument Specified Value Color bar chart (Standard picture frame) Video terminal of A/V OUT jack NTSC vectorscope Each center of all color luminance points should settle within each color reproduction frame.
Note: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO VIDEO OUT (SET UP setting) .................................... NTSC Checking method: Order Page Address Data Procedure 1 Check that "1. Data Setting during Camera System Adjustments" is performed. 2 Check the picture frame. If deviated, perform "5. Picture Frame Setting". Set the data. Write the data. Write the data. Wait for 1 sec. Write the data. Wait for 2 sec. Adjust the GAIN and PHASE of the vectorscope so that the burst luminance point is set at the specified position. Check that each center of all color luminance points is set in each color reproduction frame.
Burst position White
3 4 5 6 7 8 9
00 60 60 60
01 01 12 12
01 AB 80 00
Fig. 6-1-14.
10
Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 60 01 00 Write the data. Perform next adjustments. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
6-26
DSC-P52
17. CCD White Defect Compensation Check The positions of the white defective pixel are detected, and check that the pixels can be corrected. Mode STILL ( ) Subject Measurement Point Measuring Instrument Specified value 1 Specified value 2 Clear chart (Standard picture frame) Data of page: 60, address: 55 00 to 7F 00
Note: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: ZOOM .................................................................... WIDE end CAMERA setting (Menu setting) ................................ AUTO Adjusting method: Order Page Address Data 1 2
Procedure Install the clear chart. Check that "1. Data Setting during Camera System Adjustments" is performed. Check the picture frame. If deviated, perform "5. Picture Frame Setting". Set the data. Write the data. Write the data. Write the data. Wait for 10 sec. Read the data, and check it is "01". Read the data, and check it satisfies the specified value 1.
3
4 5 6 7 8 9 10 11 12 13 14 15 16 17
00 7D 7D 60 60 60 60 7D 7D 60 60 60
01 64 69 01 02 55 01 64 69 01 02 55
01 1E 11 8B
00 0F 60 87
Write the data. Write the data. Write the data. Write the data. Wait for 5 sec. Read the data, and check it is "01". Read the data, and check it satisfies the specified value 2.
Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 3 4 60 7D 7D 01 64 69 00 0F 0B Write the data. Write the data. Write the data. Perform next adjustments. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
6-27
DSC-P52
18. CCD Black Defect Compensation Check The positions of the black defective pixel are detected, and check that the pixels can be corrected. And confirms that there is no trash in the surface of the CCD imager, the optical filter and the inside of the lens. Mode STILL ( ) Subject Measurement Point Measuring Instrument Specified value 1 Specified value 2 Clear chart (Standard picture frame) Data of page: 60, address: 55 00 to 14 00
Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 3 4 5 6 60 60 60 60 7D 01 2C 30 91 65 00 00 00 00 4C Write the data. Write the data. Write the data. Write the data. Write the data. Perform next adjustments. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
Note1: Check that there are no dust, no dirt and no reflection on the clear chart. Note2: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: CAMERA setting (Menu setting) ................................ AUTO
Adjusting method: Order Page Address Data 1
Procedure Check that "1. Data Setting during Camera System Adjustments" is performed. Check the picture frame. If deviated, perform "5. Picture Frame Setting".
2
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
00 7D 60 60 60 60 60 60 60 60
01 65 2C 90 91 92 93 01 30 07
01 4C 01 00 03 00 00 79 08
Set the data. Write the data. Write the data. Write the data. Write the data. Write the data. Write the data. Write the data. Write the data. Read the data, and check it is "01". Check that the whole of the screen is white. Write the data. Wait for about 30 sec. Read the data, and check it is "01". Read the data, and check it satisfies the specified value 1. If the data is "00", proceed to "Processing after Completing Adjustments". Write the data. Write the data. Write the data. Wait for about 15 sec. Read the data, and check it is "01". Read the data, and check it satisfies the specified value 2.
60 60 60
01 02 55
8D
18 19 20 21 22 23
60 7D 60 60 60
01 65 01 02 55
00 5A 89
6-28
DSC-P52
19. Strobe Adjustment Adjust the light level and white balance when the strobe light flashes. Mode STILL ( ) Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value1 Specified Value2 Specified Value3 Specified Value4 Background paper (J-2501-130-A) (50cm from the front of the lens) Data of page 6F, address: E8, EA, EC, EE, B5 Data of page 10, address: 59, 5B 6F B6, B7, D8 to EF 04 to 09 7C to 84 7C to 84 00
Order Page Address Data 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 60 6F 60 60 60 60 6F 60 60 6F 60 60 6F 60 60 60 60 6F 6F 6F 6F 10 10 6F 02 D8 01 ED 01 02 D8 01 ED B5 01 02 D8 01 ED 01 02 D8 EA EC EE 59 5B B5 E7 FF B9 00
Procedure Read the data, and check it is "01". (Note5) Read the data, and check it is "00". Write the data. Wait for 5 sec. Read the data, and check it is "02". Write the data. Check the flashing. Read the data, and check it is "01". (Note5)
67
00
Read the data, and check it is "00". Write the data. Wait for 5 sec. Read the data, and check it is "02". Write the data. Write the data. Check the flashing. Read the data, and check it is "01". (Note5)
Note1: Perform this adjustment in the dark room or use the flash adjustment box. Note2: Any light other than the strobe light should not light up the paper. Note3: After the power is turned on, this adjustment can be done only once. Note4: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Adjusting method: Order Page Address Data Procedure 1 Check that "1. Data Setting during Camera System Adjustments" is performed. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 60 60 60 6F 6F 60 60 60 60 6F 60 60 60 07 01 02 D8 E8 01 ED 01 02 D8 01 ED 01 00 67 00 67 00 60 60 60 60 60 60 60 01 2C 90 91 92 93 6C 01 01 01 00 00 FF FF 01 79 Set the data. Write the data. Write the data. Write the data. Write the data. Write the data. Write the data. Write the data. Wait until the movement of the lens stops. Read the data, and check it is "01". Write the data. Check the flashing. Read the data, and check it is "01". (Note5) Read the data, and check it is "00". Read the data, and check it satisfies the specified value 1. Write the data. Wait for 5 sec. Read the data, and check it is "02". Write the data. Check the flashing. Read the data, and check it is "01". (Note5) Read the data, and check it is "00". Write the data. Wait for 5 sec. Read the data, and check it is "02". Write the data. Check the flashing.
00
Read the data, and check it is "00". Write the data. Wait for 5 sec. Read the data, and check it is "02". Write the data. Check the flashing. Read the data, and check it is "01". Read the data, and check it is "00". Read the data, and check it satisfies the specified value 1. Read the data, and check it satisfies the specified value 1. Read the data, and check it satisfies the specified value 1. Read the data, and check it satisfies the specified value 2. Read the data, and check it satisfies the specified value 3. Read the data, and check it satisfies the specified value 4.
Note5: The adjustment data will be automatically input to page: 6F, address: B6, B7, D8 to EF.
Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 3 4 5 6 7 8 60 60 60 60 60 60 60 01 2C 6C 90 91 92 93 00 00 00 00 00 00 00 Write the data. Write the data. Write the data. Write the data. Write the data. Write the data. Write the data. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
67
6-29
DSC-P52
20. Auto Focus Illumination Check Check the auto focus illumination optical axis. Mode STILL ( ) Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value1 Specified Value2 Background paper (J-2501-130-A). (50cm from the front of the lens) LCD screen or monitor TV (under scan) 6F 10 to 17 Center of luminance point should settle within the specified frame. Date of page: 6F, address:10 is "00".
Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 3 60 5F 01 3D 00 Write the data. Write the data memorized at step 3. If finish the camera system adjustments, release the data setting. (See "1. Data Setting during Camera System Adjustments".)
Note1: Perform this adjustment in the dark room or use the flash adjustment box. Note2: Any light other than the strobe light should not light up the paper. Note3: If the data of page: 60, address: 02 is "01", select page: 60, address: 01, and write data: 00.
Switch setting: CAMERA setting (Menu setting) ................................ AUTO Preparations: 1) Take a copy of the AF illumination axis frame with a clear sheet. (Reduce or enlarge the frame in same size as the effective picture frame of the LCD screen or the monitor TV.) Adjusting method: Order Page Address Data 1
Fig. 6-1-15.
Proce