Text preview for : 77iii___smeng0102.pdf part of FLUKE 77 III Fluke Multimeter 77 III



Back to : 77iii___smeng0100.pdf | Home

Manual Supplement
Manual Title: Part Number: Print Date: Revision/Date: 77 Series III Service 800604 November 1998 1, 11/99 Supplement Issue: Issue Date: Page Count: 2 2/03 1

This supplement contains information necessary to ensure the accuracy of the above manual.

© 2003 Fluke Corporation. All rights reserved. Printed in the U.S.A

N

77 Series III Service

Manual Supplement

Change #1
On page 2-4, under Current Conditioning, replace the last sentence with the following: F1 protects the mA circuitry; F2 protects the 10A circuitry.

Change #2
On page 4-5, Table 4-1, change MP14, From: 659786 To: 659128

Change #3
On page 2-7, Figure 2-2, replace the bottom half of the figure with the following:

ACTIVE FILTER

INT

R10 40 27 39 28 26

FILTER

AC

FILTER

+

R9 R19

AC CONVERTER

AC

AC

17

C5

C6

R17

R18

+

AC

AC

2/03

INPUT

1

16

C11 +

+

C9